Skip to content

What are you looking for?


You may also like

ABB DSQC 658 3HAC025779-001 Network Interface CardABB DSQC 658 3HAC025779-001 Network Interface CardABB DSQC 658 3HAC025779-001 Network Interface Card
ABB DSQC 658 3HAC025779-001 Network Interface Card
ABB DSQC 658 3HAC025779-001 Network Interface Card
ABB DSQC 658 3HAC025779-001 Network Interface Card

ABB DSQC 658 3HAC025779-001 Network Interface Card


Only 10 left - Selling fast

PRODUCT SKU : DSQC 658 3HAC025779-001

PRODUCT TYPE : Interface Modules

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for signal conversion and Ethernet integration in robotic control platforms, the ABB DSQC 658 (3HAC025779-001 Network Board) provides direct physical and electrical execution. The module serves as a protocol interface board, facilitating the translation of internal robotic controller data into Industrial Ethernet formats for external network communication.

Hardware Specifications

Parameter Specification
Model DSQC 658
Brand ABB
Operating Temp Standard Industrial
Power Consumption Configuration Dependent
Input Voltage 24 VDC

Industrial Deterministic Communication Connectivity

The DSQC 658 utilizes backplane bus communication velocity to manage the data throughput required for robotic system integration into Industrial Ethernet environments. The architecture supports I/O density scaling, enabling the controller to expand its communication reach while maintaining deterministic timing constraints. Firmware flash compatibility ensures that the interface board can be synchronized with current robot controller software versions, allowing for standardized network interoperability across various robotic workcells without requiring hardware-level modifications.

Frequently Asked Questions

Q: Does the DSQC 658 interface board support hot-swapping?

A: The DSQC 658 is not rated for hot-swap operations. The robot controller must be fully powered down and the DC supply isolated before removing or installing the interface card to prevent damage to the backplane communication pins.

Q: How is the anti-interference performance maintained for Ethernet signals?

A: The board utilizes industrial-grade switch chips and high-density PCB routing to minimize electromagnetic susceptibility. Proper grounding of the interface card via the mounting fasteners is required to ensure that the shielding integrity of the Ethernet path is preserved.

Field Installation Guidelines

  1. Ensure the robot controller is de-energized and follows lock-out/tag-out safety protocols prior to accessing the internal communication slots.
  2. Align the DSQC 658 carefully with the designated interface slot on the controller backplane.
  3. Insert the board until fully seated and ensure that the mechanical locking fasteners are tightened to establish the ground path.
  4. Connect the Industrial Ethernet cabling, ensuring that the cable is secured with appropriate strain relief to avoid mechanical stress on the board-mounted connectors.
  5. Power on the controller and perform a network handshake test via the robotic configuration interface to confirm successful packet transmission and node recognition.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more
Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Standard electromechanical relays provide basic electrical isolation between low-voltage control circuits and high-power output loads. A traditional switching relay features a magnetic coil driving mechanical Common (COM), Normally-Open (NO), and Normally-Closed (NC) contacts. However, standard relays pose severe functional risks when deployed in critical safety interlock circuits. High current inrush or mechanical wear can weld contacts together permanently. If contact welding occurs in an emergency stop circuit, pressing the button fails to halt hazardous machinery movements. Consequently, global functional safety standards prohibit standard relays for critical machine guarding functions.

Read more
Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Proper wire labeling forms the cornerstone of reliable control system installation and long-term maintenance. In complex industrial automation environments, technicians terminate thousands of conductor ends inside control panels, marshalling racks, and field junction boxes. Ferrules serve as individual tube-shaped sleeve markers slipped onto conductors before final termination. While technicians historically relied on pre-printed individual letter rings, modern control panel builders utilize automated ferrule printing machines. These thermal-transfer printers generate durable, single-sleeve heat-shrink tags directly matching approved wiring schematics, significantly accelerating cabinet assembly workflows.

Read more