Skip to content

What are you looking for?


You may also like

ABB Bailey INICT01 Infi-Net to Computer Transfer Interface ModuleABB Bailey INICT01 Infi-Net to Computer Transfer Interface ModuleABB Bailey INICT01 Infi-Net to Computer Transfer Interface Module
ABB Bailey INICT01 Infi-Net to Computer Transfer Interface Module
ABB Bailey INICT01 Infi-Net to Computer Transfer Interface Module
ABB Bailey INICT01 Infi-Net to Computer Transfer Interface Module

ABB Bailey INICT01 Infi-Net to Computer Transfer Interface Module


Only 10 left - Selling fast

PRODUCT SKU : INICT01

PRODUCT TYPE : Communication Interface Module

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Description

The ABB INICT01 is a foundational communication gateway developed for the Bailey INFI 90 distributed control system. This module serves as the primary hardware bridge between the proprietary high-speed Infi-Net (Cnet) plant loop and external host computer systems or human-machine interfaces (HMI). By translating complex network protocols into data formats compatible with PC-based applications, the INICT01 allows operators and engineers to perform real-time monitoring, system configuration, and data acquisition. It is engineered to handle high-volume data traffic while maintaining the deterministic performance required for stable industrial automation and large-scale power utility management.

Specifications

  • Brand: ABB Bailey

  • Model Number: INICT01

  • Product Series: INFI 90 / Symphony Plus

  • Module Function: Network-to-Computer Data Transfer

  • Network Protocol: Infi-Net (Cnet)

  • Backplane Interface: Harmony Control Bus / Slave Expander Bus

  • Data Throughput: High-speed serial/parallel conversion

  • Mounting: Standard Module Mounting Unit (MMU) slot

  • Power Supply: +5 VDC (backplane powered)

  • Status Monitoring: Front-panel diagnostic LED array

Features

  • Seamless Protocol Conversion: Bridges the gap between the real-time DCS network and standard supervisory computer systems.

  • Deterministic Data Handling: Ensures that critical process variables are prioritized during the transfer process to prevent information latency.

  • Integrated Hardware Buffer: Features on-board memory to manage data bursts and ensure continuous information flow without packet loss.

  • Advanced Error Detection: Performs continuous parity and checksum verification to maintain the integrity of data transferred from the plant loop.

  • Plug-and-Play Integration: Specifically designed for legacy INFI 90 architectures, allowing for easy replacement or network expansion.

  • Rugged Industrial Design: Constructed with heavy-duty components to operate reliably in high-temperature and high-vibration control environments.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more
Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Standard electromechanical relays provide basic electrical isolation between low-voltage control circuits and high-power output loads. A traditional switching relay features a magnetic coil driving mechanical Common (COM), Normally-Open (NO), and Normally-Closed (NC) contacts. However, standard relays pose severe functional risks when deployed in critical safety interlock circuits. High current inrush or mechanical wear can weld contacts together permanently. If contact welding occurs in an emergency stop circuit, pressing the button fails to halt hazardous machinery movements. Consequently, global functional safety standards prohibit standard relays for critical machine guarding functions.

Read more
Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Proper wire labeling forms the cornerstone of reliable control system installation and long-term maintenance. In complex industrial automation environments, technicians terminate thousands of conductor ends inside control panels, marshalling racks, and field junction boxes. Ferrules serve as individual tube-shaped sleeve markers slipped onto conductors before final termination. While technicians historically relied on pre-printed individual letter rings, modern control panel builders utilize automated ferrule printing machines. These thermal-transfer printers generate durable, single-sleeve heat-shrink tags directly matching approved wiring schematics, significantly accelerating cabinet assembly workflows.

Read more