Skip to content

What are you looking for?


You may also like

ABB Bailey INNPM22 Network Processing Interface ModuleABB Bailey INNPM22 Network Processing Interface ModuleABB Bailey INNPM22 Network Processing Interface Module
ABB Bailey INNPM22 Network Processing Interface Module
ABB Bailey INNPM22 Network Processing Interface Module
ABB Bailey INNPM22 Network Processing Interface Module

ABB Bailey INNPM22 Network Processing Interface Module


Only 10 left - Selling fast

PRODUCT SKU : INNPM22

PRODUCT TYPE : Network Processor Module

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Description

The ABB INNPM22 is a core network processor module designed for the Symphony Plus and INFI 90 distributed control systems. It functions as the primary intelligence for managing communications between the Harmony control unit and the high-speed INFI-Net plant loop. This module is responsible for coordinating data traffic, executing network protocols, and ensuring that process variables are synchronized across the DCS backbone. By offloading communication tasks from the main controller, the INNPM22 maintains system determinism and high-speed data throughput, making it essential for large-scale industrial plants requiring reliable, real-time information exchange between multiple control nodes.

Specifications

  • Brand: ABB Bailey

  • Model Number: INNPM22

  • Product Series: INFI 90 / Symphony Plus

  • Functional Category: Network Communication Processor

  • Communication Port: Serial interface for communication modules

  • Backplane Interface: Harmony Control Bus / Expander Bus

  • Memory: Integrated flash and RAM for protocol buffering

  • Status Indication: Multi-segment front-panel LED display

  • Power Requirements: Powered via standard backplane (+5 VDC)

  • Operating Temperature: 0 to 70 degrees Celsius

Features

  • High-Speed Throughput: Optimized for low-latency data processing across the INFI-Net communication highway.

  • Deterministic Performance: Ensures predictable data delivery cycles, which is critical for synchronous control in power and water utilities.

  • Protocol Management: Handles complex network layer tasks independently, allowing the main processor to focus exclusively on control logic.

  • Redundant Configuration: Fully supports redundant pairing to eliminate single points of failure within the communication sub-system.

  • Real-Time Diagnostics: Features comprehensive self-monitoring that reports module health and network traffic statistics to the operator workstation.

  • Backward Compatibility: Designed to integrate seamlessly with legacy INFI 90 hardware while providing the performance upgrades required for modern Symphony Plus systems.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Proper wire labeling forms the cornerstone of reliable control system installation and long-term maintenance. In complex industrial automation environments, technicians terminate thousands of conductor ends inside control panels, marshalling racks, and field junction boxes. Ferrules serve as individual tube-shaped sleeve markers slipped onto conductors before final termination. While technicians historically relied on pre-printed individual letter rings, modern control panel builders utilize automated ferrule printing machines. These thermal-transfer printers generate durable, single-sleeve heat-shrink tags directly matching approved wiring schematics, significantly accelerating cabinet assembly workflows.

Read more
Understanding Marshalling Cabinets in Industrial Automation and Control Systems

Understanding Marshalling Cabinets in Industrial Automation and Control Systems

Marshalling cabinets serve as the crucial connection hub between field instruments and centralized processing units. In large DCS and PLC control system architectures, hundreds of multipair field cables run from local junction boxes to the central instrument equipment room. The marshalling cabinet houses field terminal blocks, surge arresters, intrinsic safety isolation barriers, and interposing relays. By segregating field field-wiring terminations from sensitive processor hardware, engineers protect expensive controller backplanes from high-voltage transients. Consequently, this modular separation dramatically streamlines maintenance workflows and simplifies system expansion.

Read more
Essential Best Practices for PLC Wiring and Installation in Industrial Automation

Essential Best Practices for PLC Wiring and Installation in Industrial Automation

Successful control system deployment begins with thoroughly reviewing manufacturer technical documentation. Controllers from major brands like Allen-Bradley, Siemens, and Schneider Electric feature unique terminal layouts. Engineers must verify voltage requirements before connecting power cables to prevent catastrophic equipment damage. Standard line connections require strict adherence to regional electrical codes and proper wire color coding. Furthermore, panel builders should always establish a robust low-impedance ground connection using at least 16-AWG copper conductor tied directly to the main plant grounding grid.

Read more