Skip to content

What are you looking for?


You may also like

UP C090 AE01 HIEE300661R0001 Circuit Interface Board | ABBUP C090 AE01 HIEE300661R0001 Circuit Interface Board | ABBUP C090 AE01 HIEE300661R0001 Circuit Interface Board | ABB
UP C090 AE01 HIEE300661R0001 Circuit Interface Board | ABB
UP C090 AE01 HIEE300661R0001 Circuit Interface Board | ABB
UP C090 AE01 HIEE300661R0001 Circuit Interface Board | ABB

UP C090 AE01 HIEE300661R0001 Circuit Interface Board | ABB


Only 10 left - Selling fast

PRODUCT SKU : UP C090 AE01 HIEE300661R0001

PRODUCT TYPE : Circuit Interface Boards

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for high-speed signal conditioning and gating interface execution in power conversion systems, the ABB UP C090 AE01 HIEE300661R0001 (UPC090AE01 Circuit Interface Board) provides direct physical/electrical execution.

Hardware Specifications

Parameter Specification
Model UP C090 AE01 (HIEE300661R0001)
Brand ABB
Origin Estonia
Weight 1.00 kg (2.2 lbs)
Dimensions 180 mm x 180 mm x 100 mm
Operating Temp -10 to 60 deg C
Power Consumption 24 VDC Internal Supply
Function Type DC/AC Circuit Interface Board
System Architecture ABB Excitation & Drive Control Platforms

Deterministic Network Integration and I/O Density Scaling

The UPC090AE01 interface board process high-speed gate driver signals and DC/AC feedback circuits, interfacing directly with main controller backplanes across Profinet and EtherNet/IP deterministic networks. High backplane bus communication velocity allows rapid telemetry transmission during dynamic load adjustments. Multi-layer PCB traces allow maximum I/O density scaling inside compact excitation racks, while onboard EEPROM maintains full firmware flash compatibility during online CPU parameter updates.

Frequently Asked Questions

Q: Can the UPC090AE01 circuit interface board be replaced while the system rack is energized?

A: No, primary auxiliary power and power circuit connections must be isolated before removing or inserting the board to avoid high-voltage discharge and logic damage.

Q: How is signal reference ground integrity maintained on the UPC090AE01?

A: Functional ground connections are routed through dedicated low-impedance copper chassis standoff pads on the circuit card perimeter.

Q: What is the primary role of the UPC090AE01 within excitation control racks?

A: The board acts as an isolated conversion barrier between real-time processing units and power semiconductor drive circuits.

Field Installation Guidelines

  • Isolate all AC and DC power feeds before installing or servicing the interface card assembly.
  • Wear an ESD wrist strap connected to cabinet earth ground during handling to protect onboard CMOS circuitry.
  • Verify clean alignment of board guide rails before fully seating the backplane edge connector pins.
  • Fasten chassis retention hardware to the specified torque limit to establish solid metallic shield grounding.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
The Shift to Flexible IO Modules in Modern Industrial Automation

The Shift to Flexible IO Modules in Modern Industrial Automation

Traditional control systems rely on dedicated Input Output (IO) cards for industrial automation. Each conventional module processes a single signal type, such as Digital Input (DI), Digital Output (DO), Analog Input (AI), or Analog Output (AO). A standard 16-channel card accepts only one specific channel type across all ports. This inflexible hardware design often creates severe engineering bottlenecks during project execution. Engineers frequently must install entirely new cards to accommodate a single extra sensor. Consequently, late design changes increase control cabinet space requirements and drive up project costs.

Read more
DCS Commissioning Steps in Industrial Automation Projects

DCS Commissioning Steps in Industrial Automation Projects

Commissioning a Distributed Control System (DCS) represents a crucial milestone when deploying modern process automation infrastructure. Field engineers must execute systematic verification steps to transition complex control hardware from static installation to dynamic plant control. Proper commissioning ensures that controllers, I/O modules, network switches, and HMI software operate in strict compliance with engineering design specifications before introducing live process fluids.

Read more
PLC and DCS Control System Spares Strategy: Engineering Guidelines

PLC and DCS Control System Spares Strategy: Engineering Guidelines

Modern factory automation relies on high-speed fiber optic backbones to link distributed control systems across noise-intensive industrial environments. Unlike copper wiring, optical fibers transmit data via light pulses, making them completely immune to electromagnetic interference (EMI). Field engineers must master optical cable joining and fusion splicing techniques to guarantee low-loss data transmission across critical Programmable Logic Controller (PLC) and Distributed Control System (DCS) nodes.

Read more