SAVS20P5 Honeywell Control Panel BoardSAVS20P5 Honeywell Control Panel BoardSAVS20P5 Honeywell Control Panel Board
SAVS20P5 Honeywell Control Panel Board
SAVS20P5 Honeywell Control Panel Board
SAVS20P5 Honeywell Control Panel Board

SAVS20P5 Honeywell Control Panel Board


Only 10 left - Selling fast

PRODUCT SKU : SAVS20P5

PRODUCT TYPE : Alarm Control Boards

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Honeywell SAVS20P5, also cataloged as the SAVS20P5 Control Panel Board, operates as a dedicated hardware component for central zone monitoring and alarm loop execution within Honeywell Vista 20P security platforms.

Hardware Specifications

Parameter Specification
Model SAVS20P5
Brand Honeywell
Origin USA / As specified on hardware label
Weight 0.5 kg (1.10 lbs)
Dimensions 467 mm x 290 mm x 60 mm
Operating Temp 0 to 50 deg C
Power Consumption 24 VDC nominal power supply
Base Hardwired Zones 8 hardwired zone inputs
Expandable Capacity Expandable up to 15 zones (zone doubling on zones 2-8)
System Partitioning Supports up to 2 independent alarm partitions
Communication Interfaces Cellular and IP expansion module support

4-20 mA HART Loop Protocol and Channel-to-Channel Isolation

The SAVS20P5 manages zone input circuit state detection through dedicated onboard hardware terminals. Signal conditioning networks provide channel-to-channel isolation across input loops to prevent crosstalk and voltage surges from corrupting loop status evaluation. When integrated into broader process monitoring topologies, remote field instruments interface using 4-20 mA HART loop protocol through isolated gateway interfaces, guaranteeing clean digital signal transmission to central control nodes without ground potential interference across the main enclosure assembly.

Frequently Asked Questions

Q: How does the SAVS20P5 achieve zone expansion beyond its 8 baseline hardwired inputs?

A: Zone capacity expands up to 15 zones using hardware zone-doubling resistors across channels 2 through 8 or by integrating compatible bus expansion modules.

Q: What power input specs must be delivered to the main board terminals?

A: The SAVS20P5 main circuit board requires a stable 24 VDC external power supply feed.

Field Installation Guidelines

  • Mount the SAVS20P5 control board inside an approved metal enclosure using factory standoff supports to prevent chassis grounding shorts.
  • Disconnect primary 24 VDC input power and standby battery leads before terminating field zone wiring or installing plug-in communication modules.
  • Install specified End-of-Line (EOL) resistors across zone input terminals according to system wiring diagrams to maintain loop fault supervision.
  • Keep low-voltage DC input lines and zone sensor cabling segregated from high-voltage AC power wiring within the panel enclosure.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Step-by-Step System Cabinet Health Check Guide for PLC and DCS Infrastructure

Step-by-Step System Cabinet Health Check Guide for PLC and DCS Infrastructure

System cabinet health checks ensure long-term reliability in industrial automation. Preventative maintenance prevents hardware degradation, communication loss, and unplanned outages in control networks. This guide outlines the standard operating workflow for inspecting PLC and DCS cabinets to maintain peak performance.
Read more
Top 5 Operational Advantages of HMIs in Modern Factory Automation

Top 5 Operational Advantages of HMIs in Modern Factory Automation

HMIs bridge the gap between operators and complex industrial control networks. Modern factory automation relies on HMIs to deliver real-time visualization, precise control, and data analytics alongside PLC and DCS infrastructure. This technical guide explores five core operational benefits of deploying HMIs in manufacturing.
Read more
Importance of Safety Barriers in PLC and DCS Control Systems

Importance of Safety Barriers in PLC and DCS Control Systems

Process industries handle flammable gases and liquids, making electrical instrumentation a constant ignition risk. Engineers designing PLC and DCS networks must implement strict energy-limiting strategies. Intrinsic Safety barriers provide the critical interface that safeguards automation assets and prevents explosions.
Read more