Skip to content

What are you looking for?


You may also like

RH926JM Foxboro Panel Mounting BaseplateRH926JM Foxboro Panel Mounting BaseplateRH926JM Foxboro Panel Mounting Baseplate
RH926JM Foxboro Panel Mounting Baseplate
RH926JM Foxboro Panel Mounting Baseplate
RH926JM Foxboro Panel Mounting Baseplate

RH926JM Foxboro Panel Mounting Baseplate


Only 10 left - Selling fast

PRODUCT SKU : RH926JM

PRODUCT TYPE : System Baseplates

PRODUCT VENDOR : Foxboro


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for 8-slot vertical module mounting in Foxboro I/A Series control systems, the Foxboro RH926JM (RH926JM Baseplate) provides direct physical and electrical execution for fieldbus module power distribution and communication backplane routing.

Hardware Specifications

Parameter Specification
Model RH926JM
Brand Foxboro
Origin USA
Weight 2.5 kg (5.5 lbs)
Dimensions Standard 8-slot vertical panel footprint
Operating Temp -20 deg C to +70 deg C
Power Consumption Passive backplane bus rail
Slot Capacity 8 module slots
Mounting Orientation Vertical panel mount
Backplane Bus Dual redundant system fieldbus

Channel-to-Channel Isolation and Loop Protocol Connectivity

The Foxboro RH926JM baseplate features dual redundant fieldbus power distribution rails and isolated signal pathways. Internal galvanic isolation boundaries between primary system power terminals and fieldbus communications prevent ground loops across connected I/O channels. This bus structure maintains low noise signal transmission for field devices utilizing 4-20 mA HART loop protocol communications and cold junction compensation (CJC) sensor inputs across all 8 module positions.

Frequently Asked Questions

Q: What module orientation is required when installing the RH926JM baseplate?

A: The RH926JM is engineered specifically for vertical panel mounting within control enclosures to maintain proper thermal convection across installed modules.

Q: Does the RH926JM baseplate support redundant power feeds?

A: Yes, the internal backplane integrates dual independent 24 VDC power supply rails to ensure uninterrupted operation of installed fieldbus modules.

Field Installation Guidelines

Mount the RH926JM baseplate to a flat cabinet panel using recommended mechanical fasteners, ensuring the assembly is oriented vertically for proper airflow. Connect system ground conductors directly to the baseplate grounding stud before applying power or installing operational modules.

Route incoming dual 24 VDC power supplies and fieldbus communication cables through isolated wiring channels within the enclosure. Verify that multi-pin backplane connectors are clear of debris prior to seating fieldbus modules into any of the 8 slots. Maintain adequate clearance around the baseplate perimeter, and ensure all cabinet conduit penetrations achieve a minimum of 5 full threads of engagement on NPT fittings.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Managed Switch vs. Unmanaged Switch: Industrial Ethernet Architecture

Managed Switch vs. Unmanaged Switch: Industrial Ethernet Architecture

Industrial Ethernet forms the backbone of factory automation. Selecting the right switch architecture determines system uptime, data throughput, and OT cyber resilience. This technical guide evaluates managed vs. unmanaged switches, analyzing operational differences, security controls, and selection criteria.
Read more
Hot Standby vs. Cold Standby Redundancy in Industrial Automation

Hot Standby vs. Cold Standby Redundancy in Industrial Automation

System availability determines process safety and productivity in industrial automation. Control engineers deploy redundancy to eliminate single points of failure. This technical guide evaluates Hot Standby vs. Cold Standby architectures, comparing failover speeds, memory sync, cost trade-offs, and field selection criteria.

Read more
ON-OFF Controller vs. PID Controller: Industrial Control System Evaluation

ON-OFF Controller vs. PID Controller: Industrial Control System Evaluation

Selecting the right control strategy impacts process stability, efficiency, and equipment lifespan. This technical comparison evaluates binary ON-OFF and continuous PID control algorithms, analyzing their mathematical behavior, operational differences, and practical selection criteria for factory automation.
Read more