Product Details

Configured for high-resolution graphical operator interfacing in standard automation network architectures, the ABB CP651 1SAP551100R0001 (CP651 Control Panel) provides direct physical/electrical execution. This 10.4-inch TFT touchscreen unit functions as the primary Human Machine Interface (HMI) for local process monitoring, utilizing embedded PB610 runtime logic to visualize data arrays and execute control inputs across linked PLC hardware.

Hardware Specifications

Parameter Specification
Model CP651 1SAP551100R0001
Brand ABB
Origin Italy / Germany
Weight 2.05 kg (Net) / 2.9 kg (Gross)
Dimensions 287 mm x 232 mm x 60 mm
Operating Temp 0 deg C to +50 deg C
Power Consumption 24 W (Maximum)
Power Supply 24 VDC (18 to 30 VDC range)
Display Resolution 800 x 600 pixel (64K colors)
Memory Capacity 256 MB Flash (Data) / 256 MB DDR RAM (Program)
Protection Rating IP66 (Front) / IP20 (Housing)
Base Material Aluminium front and reverse side

Backplane Bus Communication Velocity & I/O Density Scaling

The CP651 control panel supports backplane bus communication velocity and field network topologies via dual 10/100Mbit Ethernet interfaces and a configurable RS-232/422/485 serial port. This architecture permits direct I/O density scaling and variable state polling without degrading HMI refresh rates. Firmware flash compatibility is maintained through two USB 2.0 host ports and an SD-card slot, allowing deterministic network updates and offline configuration transfers utilizing PB610 Panel Builder 600 programming structures.

Frequently Asked Questions

Q: How is the hardware real-time clock (RTC) maintained during power loss?

A: The CP651 features an integrated battery back-up circuit that sustains the hardware clock logic independently of the primary 24 VDC supply voltage.

Q: Can the dual Ethernet ports act as a managed network switch?

A: The dual Ethernet 10/100Mbit ports function as distinct network interface controllers for connecting separate automation subnets or controller clusters.

Q: What is the expected service lifecycle of the LED backlight?

A: The TFT display utilizes an industrial LED backlight matrix rated for 40,000 hours of continuous operation before reaching the half-brightness degradation threshold.

Field Installation Guidelines

Execute the following procedures during mechanical mounting and electrical termination:

  1. Panel Cutout: Prepare the cabinet door or mounting surface to the specified dimensional cutout, ensuring the surface is flat and free of debris to maintain the IP66 front seal integrity.
  2. Mounting Clips: Insert the panel from the front and secure using the provided mounting brackets on the reverse side. Tighten fasteners sequentially in a diagonal pattern to prevent chassis distortion.
  3. Power Wiring: Connect the 24 VDC supply using minimum AWG 18 wire. Verify the supply voltage remains strictly within the 18 to 30 VDC operational envelope during full load conditions.
  4. Chassis Grounding: Terminate the dedicated earth stud on the rear aluminium housing directly to the cabinet protective earth (PE) bus using a low-impedance braided ground strap to mitigate electromagnetic interference.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Emergency stop (E-Stop) pushbuttons serve as vital safety devices in factory automation and process control plants. Functional safety standards mandate normally-closed (NC) contact blocks to ensure fail-safe operation during wiring breaks or power outages. However, mechanical degradation over time can trigger unexpected spurious trips, halting production lines without an actual emergency. Understanding the underlying causes of mechanical contact failure allows automation engineers to implement robust, fault-tolerant safety circuits.

Read more
Redundant Automation Systems: Maximizing Uptime in Critical Control Applications

Redundant Automation Systems: Maximizing Uptime in Critical Control Applications

Industrial automation relies on continuous operational stability to prevent catastrophic downtime and financial loss. While standard dictionary definitions treat redundancy as superfluous, industrial engineers consider redundant control architectures indispensable for high-availability systems. Implementing backup hardware ensures seamless takeover during primary equipment failures, protecting critical infrastructure across manufacturing and process industries.

Read more
Demystifying the 5 Levels of Industrial Automation Architecture

Demystifying the 5 Levels of Industrial Automation Architecture

Modern manufacturing relies on structured communication hierarchy to bridge physical shop-floor hardware with enterprise management software. This framework, commonly known as the Automation Pyramid, establishes how data flows between field devices, logic controllers, and corporate IT networks. Understanding these five distinct levels helps engineers and plant managers optimize system operations, reduce downtime, and implement seamless factory automation solutions.

Read more