Skip to content

What are you looking for?


You may also like

Emerson 5XO0300G02 Analog Output ModuleEmerson 5XO0300G02 Analog Output ModuleEmerson 5XO0300G02 Analog Output Module
Emerson 5XO0300G02 Analog Output Module
Emerson 5XO0300G02 Analog Output Module
Emerson 5XO0300G02 Analog Output Module

Emerson 5XO0300G02 Analog Output Module


Only 10 left - Selling fast

PRODUCT SKU : 5X00300G02

PRODUCT TYPE : Analog Output Modules

PRODUCT VENDOR : EMERSON


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for high-density signal distribution in Ovation control networks, the Emerson 5XO0300G02 (5XO0300G02 Analog Output Module) provides direct physical electrical execution for multi-channel voltage command signals. The hardware enables 16-bit resolution output across a range of -10 VDC to +10 VDC to support precise actuator and process control loop requirements.

Hardware Specifications

Parameter Specification
Model 5XO0300G02
Brand Emerson
Origin USA
Weight 0.42 kg
Dimensions 173 mm x 100 mm x 42 mm
Operating Temp -40 deg C to 70 deg C
Power Consumption 24 VDC, 200 mA
Number of Channels 16
Output Range -10 VDC to +10 VDC
Accuracy 0.1%
Update Rate 250 ms

Process Instrumentation and Connectivity

The 5XO0300G02 integrates channel-to-channel isolation architecture to prevent common-mode noise propagation between distinct output circuits. This design ensures that electrical disturbances on one loop do not affect the signal integrity of adjacent channels. Furthermore, the module supports standard 4-20 mA HART loop protocol compatibility when utilized with appropriate signal converters, facilitating seamless integration with intelligent field devices within the Ovation ecosystem.

Frequently Asked Questions (FAQ)

Q: Is this module capable of hot-swapping during active process control?

A: Yes, the 5XO0300G02 is designed for hot-swap operations within the Ovation I/O rack, allowing for module replacement without interrupting the backplane communication or de-energizing the entire system.

Q: Does the 250 ms update rate represent the total throughput for all 16 channels?

A: Yes, the specified 250 ms update rate is the standard cycle time for the module to refresh the output registers across all 16 channels simultaneously.

Field Installation Guidelines

  1. Confirm the 24 VDC power supply capacity is sufficient to handle the 200 mA draw under full-load conditions to prevent voltage sagging.
  2. Ensure the module is fully seated in the backplane slot; tighten the top and bottom retaining screws to establish a secure ground connection between the chassis and the rack.
  3. Use shielded cabling for all field output wiring to prevent EMI interference, ensuring the shield drain is terminated at the designated cabinet ground bus.
  4. Route output signal wiring separately from AC power and high-current relay control lines to maintain signal purity.
  5. Verify channel-to-channel polarity during termination to avoid short-circuiting the output stages.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
PLC vs. PAC: Navigating Selection in Modern Industrial Automation

PLC vs. PAC: Navigating Selection in Modern Industrial Automation

Selecting the right controller is a fundamental decision in industrial automation. While the lines between Programmable Logic Controllers (PLC) and Programmable Automation Controllers (PAC) often blur, understanding their core architectural differences is essential for system reliability. Both controllers serve as the brain of control systems, yet their specific capabilities dictate their suitability for various factory automation tasks.

Read more
Transforming Textile Manufacturing: The Strategic Integration of Industrial Automation and AI

Transforming Textile Manufacturing: The Strategic Integration of Industrial Automation and AI

The textile industry stands at a critical technological crossroads. Legacy operations must now embrace digital transformation to remain competitive in a global market. By integrating advanced industrial automation—ranging from PLC-controlled machinery to sophisticated AI-driven analytics—manufacturers can significantly boost productivity, minimize material waste, and elevate overall product quality.

Read more
Navigating Industrial Communication Protocols: A Technical Guide for Modern PLCs

Navigating Industrial Communication Protocols: A Technical Guide for Modern PLCs

In the realm of industrial automation, the Programmable Logic Controller (PLC) serves as the brain of the factory floor. However, its true power is unlocked through robust communication protocols. These digital pathways ensure seamless data exchange between controllers, sensors, and enterprise-level management systems.

Read more