Skip to content

What are you looking for?


You may also like

PR6423/011-010 CON021 Emerson Eddy Current Displacement TransducersPR6423/011-010 CON021 Emerson Eddy Current Displacement TransducersPR6423/011-010 CON021 Emerson Eddy Current Displacement Transducers
PR6423/011-010 CON021 Emerson Eddy Current Displacement Transducers
PR6423/011-010 CON021 Emerson Eddy Current Displacement Transducers
PR6423/011-010 CON021 Emerson Eddy Current Displacement Transducers

PR6423/011-010 CON021 Emerson Eddy Current Displacement Transducers


Only 10 left - Selling fast

PRODUCT SKU : CON021+PR6423/011-010

PRODUCT TYPE : Eddy Current Displacement Transducers

PRODUCT VENDOR : EMERSON


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Emerson PR6423/011-010 CON021, also cataloged as the PR6423/011-010 CON021 Eddy Current Displacement Transducers, operates as a dedicated hardware component for non-contact dynamic shaft vibration and position measurement within turbomachinery protection systems. The system measures physical gap displacement between the sensor tip and a conductive rotating target shaft without mechanical contact.

Hardware Specifications

Parameter Specification
Model PR6423/011-010 CON021
Brand Emerson
Origin USA / Germany
Weight Approx. 100 grams (3.53 oz)
Dimensions Sensor tip: 8 mm diameter; Thread options: M10x1 or 3/8-24UNF
Operating Temp -35 to +180 deg C (-31 to +356 deg F)
Power Consumption Powered via external driver/signal converter supply rail
Static Measuring Range +/- 1.0 mm (+/- 0.04 in)
Dynamic Measuring Range 0 to 500 um (0 to 20 mils)
Sensitivity 8 V/mm (203.2 mV/mil)
Target Material Electrically conducting steel
Protection Class IP66 (IEC 60529)
Cable Length 1 meter (3.28 ft)
Product Type Eddy Current Displacement Transducers

4-20 mA HART Loop Protocol and Channel Isolation

The signal evaluation architecture paired with the PR6423/011-010 transducer incorporates channel-to-channel isolation topology to isolate primary sensor field loops from common-mode electrical noise. When interfaced with DCS systems deploying 4-20 mA HART loop protocol conditioning units or FOUNDATION Fieldbus communication interfaces, the transducer output retains factory linear scaling across dynamic spectrums. Integrated signal conditioning compensates for cold junction compensation thermal effects, maintaining stability over operational thermal windows up to +180 deg C.

Frequently Asked Questions

Q: What target shaft material is required to ensure accurate sensitivity calibration?

A: The transducer sensitivity of 8 V/mm is calibrated for electrically conducting steel targets; alternative target metallurgy requires re-calibration to account for changes in magnetic permeability and conductivity.

Q: What ingress protection level does the sensor body provide against process fluids?

A: The probe assembly complies with protection class IP66 per IEC 60529, sealing the sensor head against high-pressure liquid ingress.

Q: What is the maximum operating temperature limit for the 1-meter integral cable?

A: The integral cable and probe head assembly are rated to operate continuously across a temperature range of -35 to +180 deg C.

Field Installation Guidelines

  1. Inspect the target shaft surface to confirm it is free from mechanical scratches, burrs, and residual magnetism.
  2. Thread the sensor housing into the mounting bracket using the M10x1 or 3/8-24UNF thread option perpendicular to the shaft centerline.
  3. Adjust physical insertion depth to establish nominal mechanical air gap and target DC gap voltage before tightening the locknut.
  4. Torque the outer jam nut against the bracket to prevent rotational loosening caused by machine vibration.
  5. Route the 1-meter integral cable through protective grounded metal conduit separated from high-voltage AC cables.
  6. Connect the cable shield to the single-point instrument ground bus inside the field termination enclosure.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Demystifying the DDE Protocol in Legacy Industrial Automation Systems

Demystifying the DDE Protocol in Legacy Industrial Automation Systems

Modern control systems rely heavily on seamless interprocess communication to exchange operational data between software programs. Microsoft first introduced the Dynamic Data Exchange (DDE) protocol in 1987 to enable real-time data sharing. In factory automation, DDE served as an early bridge between control software and Windows desktop applications. Therefore, understanding DDE mechanics provides crucial insights into how legacy industrial networks established software-level connectivity.

Read more
Demystifying CPU Communication Ports in Siemens PLC Architectures

Demystifying CPU Communication Ports in Siemens PLC Architectures

Industrial automation relies heavily on robust data exchange between devices. Without seamless connectivity, field instruments, network switches, human-machine interfaces, and programmable logic controllers cannot coordinate effectively. Therefore, understanding the various CPU communication ports available in Siemens hardware ensures efficient factory automation design and seamless system integration.

Read more
Mastering the Siemens PLC Scan Cycle: How the CPU Executes Automation Programs

Mastering the Siemens PLC Scan Cycle: How the CPU Executes Automation Programs

Industrial automation relies heavily on programmable logic controllers (PLCs) to manage complex manufacturing processes. Many engineers dive straight into programming without mastering the underlying architecture. However, understanding how a PLC CPU executes a program ensures reliable system design. Therefore, mastering the scan cycle optimizes both performance and troubleshooting in modern control systems.

Read more