Skip to content

What are you looking for?


You may also like

Emerson 5X00119G02 Temperature ModuleEmerson 5X00119G02 Temperature ModuleEmerson 5X00119G02 Temperature Module
Emerson 5X00119G02 Temperature Module
Emerson 5X00119G02 Temperature Module
Emerson 5X00119G02 Temperature Module

Emerson 5X00119G02 Temperature Module


Only 10 left - Selling fast

PRODUCT SKU : 5X00119G02

PRODUCT TYPE : Temperature Input Modules

PRODUCT VENDOR : EMERSON


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for precision thermal signal acquisition in Ovation distributed control systems, the Emerson 5X00119G02 (5X00119G02) Temperature Module provides direct physical electrical execution for processing 8 RTD input channels. The hardware facilitates temperature monitoring across ranges from -200 deg C to 850 deg C, depending on the specific Resistance Temperature Detector (RTD) type connected to the field interface.

Hardware Specifications

Parameter Specification
Model 5X00119G02
Brand Emerson
Origin Not Specified
Weight Not Specified
Dimensions Standard Ovation Module Factor
Operating Temp Per Ovation Standards
Power Consumption System Powered
Channels 8 RTD Inputs

Cold Junction Compensation and Channel Isolation

The 5X00119G02 implements internal signal processing to support precise RTD measurement, requiring accurate lead-wire compensation to mitigate measurement errors induced by resistive heating in field cabling. The architecture utilizes channel-to-channel isolation to prevent ground loops and electrical interference from degrading signal accuracy in high-noise industrial environments. This design maintains measurement integrity for low-level resistance inputs, ensuring that the Ovation controller receives validated temperature data for control loop execution.

Frequently Asked Questions (FAQ)

Q: Does the 5X00119G02 support hot-swapping during active system operation?

A: The module supports hot-swap functionality within the Ovation I/O rack. Ensure that all field wiring is isolated and the I/O configuration is set to manual or maintenance mode to prevent process disturbances during the removal or insertion of the module.

Q: How should 3-wire or 4-wire RTD configurations be terminated?

A: Terminations must follow the specific Ovation terminal block wiring diagrams to ensure proper lead-wire resistance compensation. Ensure that all shield drain wires are connected to the designated ground bus to minimize noise pickup.

Field Installation Guidelines

  1. Inspect the backplane slot for connector integrity before installing the 5X00119G02 module.
  2. Align the module with the Ovation rack guide rails and press until the mechanical locking mechanism is fully engaged.
  3. Terminate RTD field inputs at the terminal assembly, ensuring wire gauge and length conform to system specifications for resistance tolerance.
  4. Verify all signal shields are grounded at a single common point within the cabinet to prevent circulating ground currents between channels.
  5. Perform an I/O loop check using a calibrated resistance simulator to verify the module input scaling and channel integrity prior to process integration.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more
Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Standard electromechanical relays provide basic electrical isolation between low-voltage control circuits and high-power output loads. A traditional switching relay features a magnetic coil driving mechanical Common (COM), Normally-Open (NO), and Normally-Closed (NC) contacts. However, standard relays pose severe functional risks when deployed in critical safety interlock circuits. High current inrush or mechanical wear can weld contacts together permanently. If contact welding occurs in an emergency stop circuit, pressing the button fails to halt hazardous machinery movements. Consequently, global functional safety standards prohibit standard relays for critical machine guarding functions.

Read more
Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Proper wire labeling forms the cornerstone of reliable control system installation and long-term maintenance. In complex industrial automation environments, technicians terminate thousands of conductor ends inside control panels, marshalling racks, and field junction boxes. Ferrules serve as individual tube-shaped sleeve markers slipped onto conductors before final termination. While technicians historically relied on pre-printed individual letter rings, modern control panel builders utilize automated ferrule printing machines. These thermal-transfer printers generate durable, single-sleeve heat-shrink tags directly matching approved wiring schematics, significantly accelerating cabinet assembly workflows.

Read more