Product Details

The ABB DSSR 116 48990001-FK, also cataloged as the DSSR 116 Power Supply Module, operates as a dedicated hardware component for internal bus power distribution and voltage stabilization within ABB control subrack systems.

Hardware Specifications

Parameter Specification
Model DSSR 116
Part Number 48990001-FK (DSSR-116)
Brand ABB
Product Type Power Supply Modules
Origin Sweden
Weight 1.70 kg (3.75 lbs)
Dimensions Standard subrack slot mount width
Operating Temp 0 to +55 deg C
Power Consumption Regulated bus power delivery output
Status Display LED indication panel on front plate
Mounting Method Slot mount chassis integration

Backplane Bus Power Integration and High I/O Density Scaling

The unit interfaces directly with the chassis backplane power rails to convert and regulate primary DC supply feeds for adjacent controller and I/O cards. High I/O density scaling relies on stable voltage outputs provided across the subrack. The integrated power control circuitry maintains backplane bus communication velocity and signal integrity by suppressing high-frequency ripple and transient voltage spikes across processing slots.

Frequently Asked Questions

Q: Does the DSSR 116 power supply module support hot-swap insertion during subrack operation?

A: No, system power feeds must be isolated and de-energized prior to inserting or removing the DSSR 116 unit to prevent voltage spikes across backplane power contacts.

Q: How are power bus fault conditions visually identified on the module?

A: Front-panel LED indicators display real-time operational status and alert technicians to supply voltage drops or system power fault conditions.

Q: How is thermal dissipation managed during continuous load conditions?

A: Heat dissipation relies on natural vertical convection through the perforated chassis enclosure; cabinet ventilation clearance must be maintained above and below the slot.

Field Installation Guidelines

  1. Isolate primary supply power prior to inserting or extracting the DSSR 116 module from the subrack slot.
  2. Align the top and bottom card guides carefully to ensure proper alignment with the rear power distribution bus.
  3. Slide the 1.70 kg module firmly into the card cage until the rear power connectors seat fully into the backplane receptacle.
  4. Fasten all front panel retaining screws to secure mechanical lock and establish frame earth ground contact.
  5. Keep high-voltage field wiring separated from adjacent low-voltage backplane communication lines by at least 200 mm.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
The Shift to Flexible IO Modules in Modern Industrial Automation

The Shift to Flexible IO Modules in Modern Industrial Automation

Traditional control systems rely on dedicated Input Output (IO) cards for industrial automation. Each conventional module processes a single signal type, such as Digital Input (DI), Digital Output (DO), Analog Input (AI), or Analog Output (AO). A standard 16-channel card accepts only one specific channel type across all ports. This inflexible hardware design often creates severe engineering bottlenecks during project execution. Engineers frequently must install entirely new cards to accommodate a single extra sensor. Consequently, late design changes increase control cabinet space requirements and drive up project costs.

Read more
DCS Commissioning Steps in Industrial Automation Projects

DCS Commissioning Steps in Industrial Automation Projects

Commissioning a Distributed Control System (DCS) represents a crucial milestone when deploying modern process automation infrastructure. Field engineers must execute systematic verification steps to transition complex control hardware from static installation to dynamic plant control. Proper commissioning ensures that controllers, I/O modules, network switches, and HMI software operate in strict compliance with engineering design specifications before introducing live process fluids.

Read more
PLC and DCS Control System Spares Strategy: Engineering Guidelines

PLC and DCS Control System Spares Strategy: Engineering Guidelines

Modern factory automation relies on high-speed fiber optic backbones to link distributed control systems across noise-intensive industrial environments. Unlike copper wiring, optical fibers transmit data via light pulses, making them completely immune to electromagnetic interference (EMI). Field engineers must master optical cable joining and fusion splicing techniques to guarantee low-loss data transmission across critical Programmable Logic Controller (PLC) and Distributed Control System (DCS) nodes.

Read more