Product Details

Configured for discrete signal switching and relay logic execution in ABB Advant Master and MasterPiece systems, the ABB DSDO-301 57160001-CC/1 (DSDO-301 Digital Output Board) provides direct physical/electrical execution.

Suffix Breakdown & Model Matrix

The DSDO-301 product series includes hardware assembly revisions and output configuration variants within the Advant Master system family:

  • DSDO-301 (57160001-CC/1): Hardware revision index /1 digital output assembly configured for 24 VDC rack integration and multi-channel field actuator switching.
  • DSDO-301 (57160001-CC): Base catalog board reference for standard rack-mount digital output configurations utilizing transistor or relay output channels.

Hardware Specifications

Parameter Specification
Model DSDO-301
Part Number 57160001-CC/1
Brand ABB
Product Type Digital Output Modules
Origin Sweden
Weight 0.40 kg
Dimensions 120 x 100 x 30 mm
Operating Temp -20 to +55 deg C
Humidity 0-95% RH, non-condensing
Power Consumption 24 VDC (Current consumption <=150 mA)
Output Channels 8 or 16 channels (variant-dependent)
Output Type Relay or transistor (variant-dependent)
Mounting Method ABB Advant Master rack system slot
RoHS Compliance Exempt (Directive 2011/65/EU, Article 2)

Industrial Control Backplane Bus Integrity and I/O Density

The board interfaces directly with the Advant Master backplane bus structure, optimizing backplane bus communication velocity and maintaining real-time data frame throughput to field output channels. By accommodating high I/O density scaling within a compact chassis slot footprint (120 x 100 x 30 mm), the card isolates external field switching noise from central processor logic. Integrated channel isolation and firmware flash compatibility ensure rapid switching synchronization and prevent transient signal feedback from disrupting adjacent processing units on the backplane bus.

Frequently Asked Questions

Q: What is the maximum backplane current draw for the DSDO-301 board under full channel load?

A: The board operates on a 24 VDC supply rail with a total current consumption rating of <=150 mA under normal channel operation.

Q: Can the DSDO-301 module be removed or inserted while the rack assembly is powered?

A: Extraction or insertion must be performed only after de-energizing rack power in accordance with standard Advant Master DCS cabinet safety guidelines to prevent backplane pin damage.

Q: How are different output channel types managed across DSDO-301 module variants?

A: The physical switching mechanism (relay or transistor) is hardware-variant dependent; channel routing configuration must align with the specified part number suffix and corresponding load requirements.

Field Installation Guidelines

  1. De-energize the central subrack power supply before inserting or extracting the DSDO-301 module from the Advant Master chassis slot.
  2. Confirm that the card guide rails are aligned correctly with the 120 x 100 x 30 mm enclosure footprint prior to final connector engagement.
  3. Push the board firmly into the backplane connector to seat all signal and power pins completely.
  4. Fasten all front panel mounting screws to establish positive chassis grounding contact and prevent vibration-induced loosening.
  5. Keep digital output field wiring separated from high-voltage AC lines by a minimum distance of 200 mm to prevent cross-talk and induced electromagnetic noise.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
The Shift to Flexible IO Modules in Modern Industrial Automation

The Shift to Flexible IO Modules in Modern Industrial Automation

Traditional control systems rely on dedicated Input Output (IO) cards for industrial automation. Each conventional module processes a single signal type, such as Digital Input (DI), Digital Output (DO), Analog Input (AI), or Analog Output (AO). A standard 16-channel card accepts only one specific channel type across all ports. This inflexible hardware design often creates severe engineering bottlenecks during project execution. Engineers frequently must install entirely new cards to accommodate a single extra sensor. Consequently, late design changes increase control cabinet space requirements and drive up project costs.

Read more
DCS Commissioning Steps in Industrial Automation Projects

DCS Commissioning Steps in Industrial Automation Projects

Commissioning a Distributed Control System (DCS) represents a crucial milestone when deploying modern process automation infrastructure. Field engineers must execute systematic verification steps to transition complex control hardware from static installation to dynamic plant control. Proper commissioning ensures that controllers, I/O modules, network switches, and HMI software operate in strict compliance with engineering design specifications before introducing live process fluids.

Read more
PLC and DCS Control System Spares Strategy: Engineering Guidelines

PLC and DCS Control System Spares Strategy: Engineering Guidelines

Modern factory automation relies on high-speed fiber optic backbones to link distributed control systems across noise-intensive industrial environments. Unlike copper wiring, optical fibers transmit data via light pulses, making them completely immune to electromagnetic interference (EMI). Field engineers must master optical cable joining and fusion splicing techniques to guarantee low-loss data transmission across critical Programmable Logic Controller (PLC) and Distributed Control System (DCS) nodes.

Read more