Only 10 left - Selling fast

PRODUCT SKU : DI571 1TNE968902R2103

PRODUCT TYPE : Digital Input Module

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The ABB DI571 (1TNE968902R2103) functions as a high-voltage digital sensing interface within the AC500-eCo PLC family. This module monitors 8 discrete AC signals ranging from 100V to 240V AC, allowing direct integration of line-voltage field devices without the need for interposing relays or step-down transformers. It utilizes a 2-wire connection scheme and a slim 34mm footprint to maximize cabinet density while providing robust signal isolation. We supply this module as 100% Brand New and Original, ensuring your automation architecture maintains factory-certified safety and logic accuracy.

Technical Specifications

The DI571 processes high-voltage AC signals through the following hardware parameters:

  • Number of Digital Inputs: 8 Channels

  • Input Voltage Range: 100V AC to 240V AC (Maximum range 0V to 264V AC)

  • Input Voltage Type: AC

  • Input Current: 8 mA per channel

  • Delay Time ($\tau$): 15 ms to 30 ms

  • Connection Type: Pluggable terminal blocks

  • Degree of Protection: IP20

  • Net Dimensions: 34 mm (W) x 74 mm (H) x 135 mm (D)

  • Operating Temperature: 0 °C to +60 °C

  • Net Weight: 0.129 kg

Engineering Advantages

  • Direct High-Voltage Interfacing: The DI571 accepts 100-240V AC inputs directly. This eliminates the hardware costs and cabinet space associated with installing external relays to convert high-voltage field signals to 24VDC logic.

  • Enhanced Signal Stability: An integrated delay time of 15-30 ms effectively filters out high-frequency noise and AC zero-crossing fluctuations common in industrial power lines. This ensures the PLC CPU receives stable, debounced logic states from limit switches and pushbuttons.

  • Optimized Slim-Line Profile: Occupying only 34 mm of DIN rail width, this module allows for high-density I/O clusters in restricted enclosures. It provides 8 high-voltage points while maintaining a compact footprint essential for decentralized control skids.

  • Rapid Maintenance with Pluggable Terminals: The pluggable connector system facilitates fast module replacement. Technicians leave the 240V field wiring intact on the connector, which prevents wiring errors and significantly reduces Mean Time to Repair (MTTR) during hardware swaps.

  • Broad Operational Range: The module operates reliably up to 264V AC, providing sufficient headroom to handle fluctuations in industrial power grids. The IP20-rated housing ensures safe mounting on standard TH35-15 DIN rails in horizontal or vertical orientations.

FAQs

  • Can the DI571 detect 24V DC signals?

    No. The DI571 specifically senses high-voltage AC signals (100-240VAC). It will not recognize 24V DC inputs as a "High" state. For DC applications, please use the DI561 or DI562 modules.

  • Does this module require a separate Terminal Base for the AC500-eCo series?

    The AC500-eCo series, including the DI571, typically utilizes a direct-pluggable terminal block system. You do not need the separate TU series terminal bases used by the standard AC500 modules, which simplifies the assembly process.

  • How do I handle the common neutral for the AC inputs?

    The DI571 requires a common neutral reference for its 8 input channels. You should refer to the specific wiring diagram provided in the AC500-eCo hardware manual to ensure correct grouping of the AC phases and neutrals.

  • Is it safe to swap the module while the 240V AC power is active?

    While the pluggable connectors offer some protection, you must always follow local safety regulations and de-energize high-voltage circuits before performing hardware maintenance to prevent electric shock or equipment damage.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Marshalling Cabinets in Industrial Automation and Control Systems

Understanding Marshalling Cabinets in Industrial Automation and Control Systems

Marshalling cabinets serve as the crucial connection hub between field instruments and centralized processing units. In large DCS and PLC control system architectures, hundreds of multipair field cables run from local junction boxes to the central instrument equipment room. The marshalling cabinet houses field terminal blocks, surge arresters, intrinsic safety isolation barriers, and interposing relays. By segregating field field-wiring terminations from sensitive processor hardware, engineers protect expensive controller backplanes from high-voltage transients. Consequently, this modular separation dramatically streamlines maintenance workflows and simplifies system expansion.

Read more
Essential Best Practices for PLC Wiring and Installation in Industrial Automation

Essential Best Practices for PLC Wiring and Installation in Industrial Automation

Successful control system deployment begins with thoroughly reviewing manufacturer technical documentation. Controllers from major brands like Allen-Bradley, Siemens, and Schneider Electric feature unique terminal layouts. Engineers must verify voltage requirements before connecting power cables to prevent catastrophic equipment damage. Standard line connections require strict adherence to regional electrical codes and proper wire color coding. Furthermore, panel builders should always establish a robust low-impedance ground connection using at least 16-AWG copper conductor tied directly to the main plant grounding grid.

Read more
Demystifying Programmable Logic Controllers: Comprehensive Guide to PLC Classification and Selection in Industrial Automation

Demystifying Programmable Logic Controllers: Comprehensive Guide to PLC Classification and Selection in Industrial Automation

Modern industrial automation heavily relies on Programmable Logic Controllers (PLCs) to drive factory floor efficiency. Over my 15 years as an industrial automation expert working with DCS, TSI, and control systems, I have seen PLCs evolve into the central nervous system of modern manufacturing. Selecting the right controller requires a deep understanding of PLC types based on physical size, hardware architecture, and power supply configurations.

Read more