Skip to content

What are you looking for?


You may also like

ABB UG A469 AE02 HIEE200024R0002 Managed Industrial Ethernet SwitchABB UG A469 AE02 HIEE200024R0002 Managed Industrial Ethernet SwitchABB UG A469 AE02 HIEE200024R0002 Managed Industrial Ethernet Switch
ABB UG A469 AE02 HIEE200024R0002 Managed Industrial Ethernet Switch
ABB UG A469 AE02 HIEE200024R0002 Managed Industrial Ethernet Switch
ABB UG A469 AE02 HIEE200024R0002 Managed Industrial Ethernet Switch

ABB UG A469 AE02 HIEE200024R0002 Managed Industrial Ethernet Switch


Only 10 left - Selling fast

PRODUCT SKU : UG A469 AE02 HIEE200024R0002

PRODUCT TYPE : Managed Industrial Ethernet Switches

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for high-speed packet management and network path termination in ABB automation networks, the ABB UG A469 AE02 HIEE200024R0002 (UG A469 AE02 Managed Industrial Ethernet Switch) provides direct physical/electrical execution. The module manages data traffic across 8 10/100Base-TX RJ-45 Ethernet ports, processing Layer 2 switching frames to maintain deterministic fieldbus communications between remote I/O drops, controllers, and human-machine interface nodes.

Hardware Specifications

Parameter Specification
Model UG A469 AE02 HIEE200024R0002
Brand ABB
Product Type Managed Industrial Ethernet Switches
Port Count 8 x 10/100Base-TX RJ-45 Ethernet ports
Power Supply Input 24 VDC nominal
Dimensions 72.8 mm x 110 mm x 131 mm (D x W x H)
Weight 0.6 kg
Operating Temp 0 to +60 deg C (standard panel ambient)
Power Consumption Operating current drawn via 24 VDC supply rail

Backplane Bus Communication Velocity and Deterministic Networks

The switch coordinates local Ethernet frames to optimize backplane bus communication velocity across networked control racks. By prioritizing time-critical automation protocols across Profinet and EtherNet/IP deterministic networks, the hardware prevents network latency during high traffic bursts. Hardware-level frame verification ensures maximum firmware flash compatibility across connected controller platforms and remote I/O nodes.

Frequently Asked Questions

Q: What power input voltage is required to operate the HIEE200024R0002 switch?

A: The device operates on a standard 24 VDC industrial power feed connected via the external power terminal interface.

Q: How is the HIEE200024R0002 switch physically secured inside a control cabinet?

A: The enclosure incorporates an integrated DIN-rail mounting mechanism designed for attachment onto standard 35 mm DIN rails.

Field Installation Guidelines

  1. Mounting Procedure: Hook the top groove of the rear DIN-rail clip onto the 35 mm rail and press the bottom downward until the latch clicks into position.
  2. Power Wiring: Connect the 24 VDC supply lines to the power terminal block, ensuring correct terminal polarity and tightening torque.
  3. Cable Termination: Plug Category 5e or Category 6 shielded RJ-45 cables into the 10/100Base-TX ports until the retaining clips engage fully.
  4. Shield Grounding: Ensure field network cable shields are bonded to the grounding system to mitigate electromagnetic interference in industrial environments.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
The Shift to Flexible IO Modules in Modern Industrial Automation

The Shift to Flexible IO Modules in Modern Industrial Automation

Traditional control systems rely on dedicated Input Output (IO) cards for industrial automation. Each conventional module processes a single signal type, such as Digital Input (DI), Digital Output (DO), Analog Input (AI), or Analog Output (AO). A standard 16-channel card accepts only one specific channel type across all ports. This inflexible hardware design often creates severe engineering bottlenecks during project execution. Engineers frequently must install entirely new cards to accommodate a single extra sensor. Consequently, late design changes increase control cabinet space requirements and drive up project costs.

Read more
DCS Commissioning Steps in Industrial Automation Projects

DCS Commissioning Steps in Industrial Automation Projects

Commissioning a Distributed Control System (DCS) represents a crucial milestone when deploying modern process automation infrastructure. Field engineers must execute systematic verification steps to transition complex control hardware from static installation to dynamic plant control. Proper commissioning ensures that controllers, I/O modules, network switches, and HMI software operate in strict compliance with engineering design specifications before introducing live process fluids.

Read more
PLC and DCS Control System Spares Strategy: Engineering Guidelines

PLC and DCS Control System Spares Strategy: Engineering Guidelines

Modern factory automation relies on high-speed fiber optic backbones to link distributed control systems across noise-intensive industrial environments. Unlike copper wiring, optical fibers transmit data via light pulses, making them completely immune to electromagnetic interference (EMI). Field engineers must master optical cable joining and fusion splicing techniques to guarantee low-loss data transmission across critical Programmable Logic Controller (PLC) and Distributed Control System (DCS) nodes.

Read more