The ABB NTAO02-AR-C, also cataloged as the NTAO02-AR-C Temperature and Humidity Control Module, operates as a dedicated hardware component for process sensor signal acquisition and analog output generation within ABB Bailey platforms.

Hardware Specifications

Parameter Specification
Model NTAO02-AR-C
Brand ABB
Origin Sweden
Weight 0.50 kg (1.1 lbs)
Dimensions 96 mm x 96 mm x 60 mm (3.8 in x 3.8 in x 2.4 in)
Operating Temp -20 to 60 deg C
Power Consumption 24 VDC Nominal
Input Signal Range 4-20 mA / 0-10 VDC
Output Signal Range 4-20 mA / 0-10 VDC
Accuracy +/-0.5%
Resolution 0.1%
Protection Rating IP65

Deterministic Network Integration and I/O Density Scaling

The NTAO02-AR-C module conditions analog process feedback into digital control loops across Profinet and EtherNet/IP deterministic networks. Onboard isolation stages prevent ground potential shifts from degrading channel measurement accuracy. Dynamic memory structures maintain uncorrupted backplane bus communication velocity during peak I/O density scaling, while hardware logic ensures full firmware flash compatibility during controller routine execution.

Frequently Asked Questions

Q: Does the NTAO02-AR-C support hot-swapping while the host panel backplane is energized?

A: No, system power must be isolated prior to removing or installing the module to avoid signal bus interruptions and transient overvoltage faults.

Q: How is the module mounted inside an enclosure?

A: The chassis accommodates mounting directly onto a standard 35 mm DIN rail or flush mounting through a designated panel cut-out.

Q: What protection level does the NTAO02-AR-C enclosure provide against dust and liquid ingress?

A: The front housing meets IP65 protection standards when properly sealed against the panel cutout surface.

Field Installation Guidelines

  • Isolate all 24 VDC power feeds and field wiring loops before performing module installation or terminal wiring.
  • Ensure proper terminal strip torque to maintain low-resistance contact on 4-20 mA and 0-10 VDC analog cable ends.
  • Ground all field cable shields at a single point on the enclosure functional earth bus to prevent ground loops.
  • Maintain minimum vertical clearance around the module housing to facilitate thermal convection inside the panel enclosure.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
The Shift to Flexible IO Modules in Modern Industrial Automation

The Shift to Flexible IO Modules in Modern Industrial Automation

Traditional control systems rely on dedicated Input Output (IO) cards for industrial automation. Each conventional module processes a single signal type, such as Digital Input (DI), Digital Output (DO), Analog Input (AI), or Analog Output (AO). A standard 16-channel card accepts only one specific channel type across all ports. This inflexible hardware design often creates severe engineering bottlenecks during project execution. Engineers frequently must install entirely new cards to accommodate a single extra sensor. Consequently, late design changes increase control cabinet space requirements and drive up project costs.

Read more
DCS Commissioning Steps in Industrial Automation Projects

DCS Commissioning Steps in Industrial Automation Projects

Commissioning a Distributed Control System (DCS) represents a crucial milestone when deploying modern process automation infrastructure. Field engineers must execute systematic verification steps to transition complex control hardware from static installation to dynamic plant control. Proper commissioning ensures that controllers, I/O modules, network switches, and HMI software operate in strict compliance with engineering design specifications before introducing live process fluids.

Read more
PLC and DCS Control System Spares Strategy: Engineering Guidelines

PLC and DCS Control System Spares Strategy: Engineering Guidelines

Modern factory automation relies on high-speed fiber optic backbones to link distributed control systems across noise-intensive industrial environments. Unlike copper wiring, optical fibers transmit data via light pulses, making them completely immune to electromagnetic interference (EMI). Field engineers must master optical cable joining and fusion splicing techniques to guarantee low-loss data transmission across critical Programmable Logic Controller (PLC) and Distributed Control System (DCS) nodes.

Read more