Product Details

The ABB ICSO 16 N1 FPR3313101R0056, also cataloged as the ICSO 16 N1 Binary Output Module, operates as a dedicated hardware component for high-voltage discrete switching within ABB automation control platforms. It processes 220 VAC binary signals across 16 channels to drive actuators, solenoids, interposing relays, and status indicators directly from controller bus commands.

Hardware Specifications

Parameter Specification
Model ICSO 16 N1 (FPR3313101R0056)
Brand ABB
Origin Germany
Product Type Binary Output Modules
Output Channels 16 channels (220 VAC, 16-fold execution)
Nominal Voltage 220 VAC
Dimensions Standard DIN rack module form factor (Gross volume 1.67 dm3)
Net Weight 0.3 kg
Operating Temp 0 to +55 deg C
Power Consumption System backplane and external field voltage dependent
Mounting Type Subrack slot insertion / terminal unit mounting

Firmware Flash Compatibility and Deterministic Switching

The module maintains synchronized backplane communications with the main controller to process output state updates without signal latency. Built-in logic execution circuits evaluate field feedback states against internal register commands before switching output stages. Internal status flags and firmware flash compatibility enable non-volatile storage of channel configuration states, ensuring controlled state retention or default fail-safe de-energization in the event of backplane bus interruptions.

Frequently Asked Questions

Q: Does the module require an external voltage supply for channel operation?

A: Yes, the output contacts route external 220 VAC utility power to field devices, while the module logic interface draws operating power from the system rack backplane bus.

Q: How does the module handle output circuit faults or overcurrent conditions?

A: Each output circuit is designed for load isolation, preventing field short circuits or line spikes from traveling back to the central controller backplane.

Field Installation Guidelines

  1. Power Isolation: Disconnect all 220 VAC external field power sources and rack supply power before inserting or removing the module from the mounting assembly.
  2. Mechanical Seating: Align the printed circuit board edges with the slot guide rails and push firmly until the backplane interface connectors are fully engaged.
  3. Wiring Separation: Route 220 VAC high-voltage output cables in dedicated wire trunks separate from low-voltage DC communication lines to eliminate capacitive cross-talk and inductive noise.
  4. Grounding Protocol: Connect shield drains and panel enclosure grounds directly to the central earth ground bus bar using short, low-impedance grounding conductors.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
The Shift to Flexible IO Modules in Modern Industrial Automation

The Shift to Flexible IO Modules in Modern Industrial Automation

Traditional control systems rely on dedicated Input Output (IO) cards for industrial automation. Each conventional module processes a single signal type, such as Digital Input (DI), Digital Output (DO), Analog Input (AI), or Analog Output (AO). A standard 16-channel card accepts only one specific channel type across all ports. This inflexible hardware design often creates severe engineering bottlenecks during project execution. Engineers frequently must install entirely new cards to accommodate a single extra sensor. Consequently, late design changes increase control cabinet space requirements and drive up project costs.

Read more
DCS Commissioning Steps in Industrial Automation Projects

DCS Commissioning Steps in Industrial Automation Projects

Commissioning a Distributed Control System (DCS) represents a crucial milestone when deploying modern process automation infrastructure. Field engineers must execute systematic verification steps to transition complex control hardware from static installation to dynamic plant control. Proper commissioning ensures that controllers, I/O modules, network switches, and HMI software operate in strict compliance with engineering design specifications before introducing live process fluids.

Read more
PLC and DCS Control System Spares Strategy: Engineering Guidelines

PLC and DCS Control System Spares Strategy: Engineering Guidelines

Modern factory automation relies on high-speed fiber optic backbones to link distributed control systems across noise-intensive industrial environments. Unlike copper wiring, optical fibers transmit data via light pulses, making them completely immune to electromagnetic interference (EMI). Field engineers must master optical cable joining and fusion splicing techniques to guarantee low-loss data transmission across critical Programmable Logic Controller (PLC) and Distributed Control System (DCS) nodes.

Read more