Skip to content

What are you looking for?


You may also like

ABB HA C807 B101 GD C806 A101 3BHE039221R0101 Control PCBABB HA C807 B101 GD C806 A101 3BHE039221R0101 Control PCBABB HA C807 B101 GD C806 A101 3BHE039221R0101 Control PCB
ABB HA C807 B101 GD C806 A101 3BHE039221R0101 Control PCB
ABB HA C807 B101 GD C806 A101 3BHE039221R0101 Control PCB
ABB HA C807 B101 GD C806 A101 3BHE039221R0101 Control PCB

ABB HA C807 B101 GD C806 A101 3BHE039221R0101 Control PCB


Only 10 left - Selling fast

PRODUCT SKU : HA C807 B101 3BHE039221R0101

PRODUCT TYPE : Control Circuit Boards

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The ABB 3BHE039221R0101, also cataloged as the HA C807 B101 Circuit Board, operates as a dedicated hardware component for signal processing and logic management within ABB industrial control system platforms. The unit acts as a direct physical execution module, managing multi-connector routing and signal conversion logic. Operating as a replacement circuit board within subrack assemblies, it maintains internal control loop integrity and board-level data routing without introducing switching latencies.

Hardware Specifications

Parameter Specification
Model 3BHE039221R0101
Sub-Model HA C807 B101
Brand ABB
Origin Switzerland
Weight 0.4 kg
Dimensions 250 x 150 x 20 mm
Operating Temp -20 deg C to +60 deg C
Power Consumption Standard Backplane Draw
Hardware Type Circuit Board / PCB Card
Primary Function Signal processing and control logic
Physical Interfaces Multiple integrated connectors for system integration

Backplane Bus Communication Velocity and I/O Density Scaling

The circuit architecture optimizes backplane bus communication velocity across system interconnects to enforce real-time determinism during logic evaluation. High-density trace routing supports expanded I/O density scaling while isolating critical processing paths from electromagnetic interference. Low-latency internal firmware flash compatibility ensures synchronized state execution between primary processing nodes and secondary expansion interfaces during continuous operation.

Frequently Asked Questions

Q: What precautions should be observed regarding static electricity during installation of this board?

A: Technicians must wear a grounded wrist strap connected to cabinet earth ground prior to handling the circuit board. Unshielded PCB traces and multi-pin connectors must not be touched directly to prevent electrostatic discharge damage.

Q: How are physical signal lines interfaced to the board assembly?

A: Signal connections are established using the integrated multi-connector physical interfaces on the board, which matingly engage with the dedicated cabinet backplane or ribbon harness assemblies.

Field Installation Guidelines

  • Verify that main cabinet supply power and backplane bus power are completely de-energized prior to inserting or removing the circuit board.
  • Ensure card edge guides align correctly with rack chassis tracks before pushing the board firmly into the mating backplane connectors.
  • Torquing panel retaining screws to standard chassis specifications prevents physical detachment caused by operational mechanical vibration.
  • Maintain clean air circulation around the rack to prevent conductive dust accumulation on exposed printed circuit traces.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Industrial manufacturing requires continuous uptime to prevent equipment damage. Unlike AC power, 24V DC circuits seamlessly integrate with UPS units and battery banks. During main grid failures, a 24V DC backup system instantly maintains PLC memory, instrument loops, and critical safety valves without interruption.

Read more
Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

The Site Acceptance Test (SAT) represents the definitive handover stage in industrial automation projects. While the Factory Acceptance Test confirms cabinet hardware assembly off-site, the SAT validates real-world performance under live site conditions. Consequently, a structured execution strategy prevents equipment damage and guarantees seamless integration into plant operations.

Read more
Mastering the Factory Acceptance Test (FAT) for PLC Control Panels: An Expert Guide

Mastering the Factory Acceptance Test (FAT) for PLC Control Panels: An Expert Guide

The Factory Acceptance Test (FAT) is a vital milestone in industrial automation that ensures custom PLC panels meet exact design specifications before dispatch. This guide outlines the step-by-step FAT procedure and key industry best practices to prevent costly site delays and ensure long-term operational success.

Read more