Only 10 left - Selling fast

PRODUCT SKU : DSBB 172B 3BSE014017R1

PRODUCT TYPE : Central Units

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The ABB 3BSE014017R1, also cataloged as the DSBB 172B Central Units, operates as a dedicated hardware component for backplane bus signal distribution and module interconnectivity within ABB Advant Master control subracks.

Hardware Specifications

Parameter Specification
Model DSBB 172B
Order Code 3BSE014017R1
Brand ABB
Origin Sweden
Product Type Central Units
Function PBC Backplane Board
Weight 0.555 kg
Dimensions Standard Advant subrack backplane footprint (> 50 cm)
Operating Temp 0 to 55 deg C
Power Consumption Passive backplane routing
WEEE Category 4. Large Equipment (Any External Dimension More Than 50 cm)

Backplane Bus Communication & I/O Density Scaling

The ABB DSBB 172B backplane board establishes high-speed electrical traces for internal power rails, address lines, and parallel data buses connecting processor cards to subrack I/O channels. By maintaining stable trace impedance across all slot positions, the assembly prevents signal crosstalk during high-frequency backplane clock cycles. The multi-slot backplane architecture facilitates flexible I/O density scaling without inducing communication latency or requiring firmware flash updates on installed slave cards.

Frequently Asked Questions

Q: What primary physical function does the DSBB 172B backplane fulfill inside the subrack?

A: The DSBB 172B provides structural mounting slots and backplane trace paths for power distribution and data bus communication between central processing modules and I/O cards.

Q: Can subrack modules be inserted onto the DSBB 172B backplane while the system is powered?

A: Main power to the backplane assembly must be isolated before installing or removing modules to prevent electrical arcing across edge connectors and data corruption on the backplane bus.

Field Installation Guidelines

  1. Disconnect all primary AC/DC power sources feeding the subrack frame before mounting or servicing the DSBB 172B backplane.
  2. Secure the backplane board flatly into the chassis framework using all designated corner and center grounding screws.
  3. Torque retaining fasteners to standard panel specifications to ensure a low-resistance earth bond with the enclosure frame.
  4. Verify that signal cable shield clamps are attached to the central protective ground bar to suppress external electromagnetic interference.
  5. Inspect all connector pins for alignment before locking subrack processor and I/O modules into their respective slots.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling cabinets serve as the vital interface between field instrumentation and control room electronics in modern process facilities. Regular preventive maintenance of these cabinets ensures signal integrity across programmable logic controllers (PLCs), distributed control systems (DCS), and emergency shutdown (ESD) networks. System technicians must execute structured inspection protocols to mitigate environmental risks, identify loose wiring, and maintain continuous operational readiness.

Read more
Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Industry 4.0 integrates digital intelligence into field operations, transforming factory automation landscapes worldwide. Spatial technologies—specifically Augmented Reality (AR) and Virtual Reality (VR)—redefine how engineers interact with industrial control systems. By bridging computer-generated CAD models with real-time operational technology (OT) data, immersive displays enable intuitive monitoring, rapid diagnostics, and safer maintenance across complex processing facilities.

Read more
Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Factory Acceptance Testing (FAT) and Site Acceptance Testing (SAT) serve as critical quality assurance gateways in complex industrial control systems. Both procedures verify that programmable logic controllers (PLCs), distributed control systems (DCS), and associated field devices meet strict functional specifications. However, executing these tests effectively requires clear delineation between off-site staging and final field commissioning.

Read more