Skip to content

What are you looking for?


You may also like

ABB DSAI 133 Analog Input Board | 57120001-PSABB DSAI 133 Analog Input Board | 57120001-PSABB DSAI 133 Analog Input Board | 57120001-PS
ABB DSAI 133 Analog Input Board | 57120001-PS
ABB DSAI 133 Analog Input Board | 57120001-PS
ABB DSAI 133 Analog Input Board | 57120001-PS

ABB DSAI 133 Analog Input Board | 57120001-PS


Only 10 left - Selling fast

PRODUCT SKU : DSAI 133 57120001-PS

PRODUCT TYPE : Analog Input Modules

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The ABB DSAI 133 57120001-PS, also cataloged as the DSAI 133 Analog Input Modules, operates as a dedicated hardware component for high-density analog signal acquisition within ABB Advant Master process control systems.

Hardware Specifications

Parameter Specification
Model DSAI 133
Order Code 57120001-PS
Brand ABB
Origin Sweden
Product Type Analog Input Modules
Input Channels 32 Channels
Input Configuration Single-Ended Input
Signal Ranges +10 V, +20 mA
Measurement Accuracy 0.025%
Dimensions 324 mm x 9 mm x 234 mm
Weight 0.4 kg
Operating Temp 0 to 55 deg C
Power Consumption Bus-powered via subrack backplane
RoHS Compliance Exempt from 2011/65/EU under Article 2(4)
WEEE Category 5. Small Equipment (No External Dimension More Than 50 cm)

Backplane Bus Communication & I/O Density Scaling

The ABB DSAI 133 analog input board multiplexes 32 single-ended analog channels to convert field voltage (+10 V) and current (+20 mA) signals into digital execution data with 0.025% accuracy. Transmitted over the Advant Master backplane bus interface, high-density channel mapping reduces backplane slot consumption. Standardized bus timing and firmware flash compatibility enable deterministic real-time scan cycles across dense I/O node configurations.

Frequently Asked Questions

Q: What signal types and input configurations are supported by the DSAI 133 module?

A: The board supports 32 single-ended input channels designed for +10 V voltage or +20 mA current loops.

Q: Can the DSAI 133 module be hot-swapped while the subrack backplane is active?

A: Main backplane power to the slot must be isolated or the slot deactivated prior to module extraction to prevent bus logic corruption and electrical stress on high-density multiplexing circuits.

Field Installation Guidelines

  1. De-energize the target subrack slot before installing or removing the DSAI 133 card.
  2. Align the board edges precisely with the subrack guide tracks and insert until the rear edge connector firmly seats into the backplane receptacle.
  3. Fasten top and bottom retaining screws on the front panel to lock the assembly and complete the protective chassis ground path.
  4. Route single-ended analog signal cables in shielded twisted-pair runs isolated from AC high-voltage lines to maintain signal accuracy.
  5. Terminate field cable shields at the designated chassis grounding bus bar prior to applying system operating power.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Industry 4.0 integrates digital intelligence into field operations, transforming factory automation landscapes worldwide. Spatial technologies—specifically Augmented Reality (AR) and Virtual Reality (VR)—redefine how engineers interact with industrial control systems. By bridging computer-generated CAD models with real-time operational technology (OT) data, immersive displays enable intuitive monitoring, rapid diagnostics, and safer maintenance across complex processing facilities.

Read more
Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Factory Acceptance Testing (FAT) and Site Acceptance Testing (SAT) serve as critical quality assurance gateways in complex industrial control systems. Both procedures verify that programmable logic controllers (PLCs), distributed control systems (DCS), and associated field devices meet strict functional specifications. However, executing these tests effectively requires clear delineation between off-site staging and final field commissioning.

Read more
Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial automation relies heavily on robust networking infrastructure to connect programmable logic controllers (PLCs), distributed control systems (DCS), and human-machine interfaces (HMIs). Modern factory automation environments generate vast amounts of real-time operational data across deterministic networks. Understanding the structural differences between hubs, switches, and routers ensures optimal traffic segmentation, minimizes latency, and maintains high network availability.

Read more