The ABB CB801 3BSE042245R1, also cataloged as the CB801 PROFIBUS DP Communication Module, operates as a dedicated hardware component for fieldbus data exchange within Panel 800 control platforms.

Hardware Specifications

Parameter Specification
Model CB801 (3BSE042245R1)
Brand ABB
Origin Sweden / Germany
Weight 0.2 kg
Dimensions 121.5 mm x 49.5 mm x 153 mm
Operating Temp -20 deg C to +70 deg C
Power Consumption Varies based on fieldbus transceiver load
Product Type Communication Expansion Module
Communication Protocol PROFIBUS DP Slave
Baud Rate 9.6 kbps to 12 Mbps
Fieldbus Interface RS-485 serial hardware connection

Deterministic Network Backplane and System Signal Integrity

The CB801 expansion module establishes cyclic slave data exchange across PROFIBUS DP deterministic networks at baud rates up to 12 Mbps. Interfacing via an RS-485 serial architecture, the internal communication logic coordinates cyclic I/O data frames with minimal backplane latency.

The hardware architecture provides galvanic isolation along the fieldbus interface to prevent ground potential loops and suppress transient surge coupling. Full firmware flash compatibility ensures seamless integration with Panel 800 operator hardware without interrupting local backplane bus communication velocity.

Frequently Asked Questions

Q: Does the CB801 module automatically match the PROFIBUS DP master baud rate?

A: Yes, the onboard PROFIBUS controller performs automatic baud rate detection from 9.6 kbps up to 12 Mbps upon network initialization.

Q: Can the CB801 module be installed while the host Panel 800 terminal remains powered?

A: No, the host terminal must be completely powered down prior to inserting or removing the CB801 expansion module from the interface bay.

Q: What physical bus medium is required to connect the CB801 to the fieldbus network?

A: Connections must be made using standard shielded twisted-pair cable complying with PROFIBUS DP RS-485 physical layer specifications.

Field Installation Guidelines

  • De-energize all primary power supplies to the Panel 800 terminal before inserting the module into the expansion slot.
  • Attach a grounded wrist strap to prevent electrostatic discharge when handling the internal module PCB and connector pins.
  • Slide the CB801 module straight into the dedicated slot until the multi-pin backplane connector seats completely.
  • Fasten all mechanical retaining screws to ensure proper grounding continuity through the chassis enclosure.
  • Route PROFIBUS DP cables away from high-voltage AC lines and VFD output wiring to maintain communication signal integrity.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Engineering a Process Control System Philosophy: Principles and Operational Impact

Engineering a Process Control System Philosophy: Principles and Operational Impact

A Process Control System (PCS) Philosophy serves as the foundational blueprint for modern plant engineering. During the design and construction phases, this document establishes clear guidelines for instrumentation and control (I&C) teams. Consequently, a well-defined philosophy directly dictates overall operational stability, maintenance efficiency, and future expansion capabilities across heavy process industries.

Read more
Engineering MCC Signal Interface Terminations in Modern Process Automation

Engineering MCC Signal Interface Terminations in Modern Process Automation

Industrial manufacturing plants rely on Motor Control Centers (MCC) to drive critical electrical loads. Plant engineers must interface these MCC motor starters and drives with central control systems. Standardizing the Signal Interface Termination (SIT) architecture ensures seamless command delivery and feedback monitoring between field equipment and process automation platforms.

Read more
Layer-2 vs. Layer-3 Network Switches in Industrial Control Systems

Layer-2 vs. Layer-3 Network Switches in Industrial Control Systems

Modern factory automation relies heavily on robust Industrial Ethernet communications. Control system engineers deploy managed Ethernet switches to connect programmable logic controllers (PLCs), distributed control systems (DCS), human-machine interfaces (HMIs), and field I/O devices. Selecting between Layer-2 and Layer-3 switching architecture directly impacts network throughput, routing capabilities, and overall cybersecurity defense in operational technology (OT) networks.

Read more