Skip to content

What are you looking for?


You may also like

57120001-HZ | ABB DSAI 155 Analog Input Board57120001-HZ | ABB DSAI 155 Analog Input Board57120001-HZ | ABB DSAI 155 Analog Input Board
57120001-HZ | ABB DSAI 155 Analog Input Board
57120001-HZ | ABB DSAI 155 Analog Input Board
57120001-HZ | ABB DSAI 155 Analog Input Board

57120001-HZ | ABB DSAI 155 Analog Input Board


Only 10 left - Selling fast

PRODUCT SKU : DSAI 155 57120001-HZ

PRODUCT TYPE : Analog Input Modules

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for high-accuracy analog signal acquisition in ABB Advant Master process control networks, the ABB DSAI 155 57120001-HZ (DSAI 155 Analog Input Modules) provides direct physical/electrical execution.

Hardware Specifications

Parameter Specification
Model DSAI 155
Order Code 57120001-HZ
Brand ABB
Origin Sweden
Product Type Analog Input Modules
Input Signal Type Analog Input Signals
Weight 0.54 kg
Dimensions Standard Advant Master subrack card dimensions
Operating Temp 0 to 55 deg C
Power Consumption Bus-powered via subrack backplane
Customs Tariff Number 85389099
Replaced Product ID 7650055-140

Backplane Bus Communication & I/O Density Scaling

The ABB DSAI 155 analog input board digitizes incoming process signals and streams digitized process values over the internal rack backplane interface to host controllers. The board design supports high I/O density scaling within S100 subracks while preserving signal conversion speed. Factory firmware flash compatibility enables deterministic scan execution across assigned process control nodes.

Frequently Asked Questions

Q: What action is required regarding the backplane interface when replacing a DSAI 155 card?

A: Auxiliary loop and subrack backplane power must be isolated before extracting or inserting the board to prevent logic communication glitches and bus transceiver stress.

Q: How does the DSAI 155 board maintain process signal integrity across the backplane?

A: On-board conditioning filters high-frequency industrial noise before analog-to-digital conversion, ensuring accurate measurement values are written directly to backplane bus registers.

Field Installation Guidelines

  1. Turn off main power to the target I/O subrack prior to inserting or removing the DSAI 155 module.
  2. Carefully align board edge connectors with the subrack guide tracks and insert until the rear plug engages fully into the backplane socket.
  3. Tighten faceplate mounting screws firmly to lock the card into position and secure the ground path to the rack chassis.
  4. Keep analog input cables routed in shielded twisted-pair conduits separate from high-voltage AC lines.
  5. Ground field cable shields at the dedicated cabinet ground bar before applying operational power.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Industry 4.0 integrates digital intelligence into field operations, transforming factory automation landscapes worldwide. Spatial technologies—specifically Augmented Reality (AR) and Virtual Reality (VR)—redefine how engineers interact with industrial control systems. By bridging computer-generated CAD models with real-time operational technology (OT) data, immersive displays enable intuitive monitoring, rapid diagnostics, and safer maintenance across complex processing facilities.

Read more
Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Factory Acceptance Testing (FAT) and Site Acceptance Testing (SAT) serve as critical quality assurance gateways in complex industrial control systems. Both procedures verify that programmable logic controllers (PLCs), distributed control systems (DCS), and associated field devices meet strict functional specifications. However, executing these tests effectively requires clear delineation between off-site staging and final field commissioning.

Read more
Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial automation relies heavily on robust networking infrastructure to connect programmable logic controllers (PLCs), distributed control systems (DCS), and human-machine interfaces (HMIs). Modern factory automation environments generate vast amounts of real-time operational data across deterministic networks. Understanding the structural differences between hubs, switches, and routers ensures optimal traffic segmentation, minimizes latency, and maintains high network availability.

Read more