PRODUCT SKU : 3BHE035301R1002

PRODUCT TYPE : Power Modules

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The ABB 3BHE035301R1002, also cataloged as the 3BHE035301R1002 Power Module, operates as a dedicated hardware component for AC to DC voltage conversion and power distribution within Unitrol 1010 excitation system platforms. The unit converts a wide-range AC input into a regulated 24 VDC bus output to energize control logic, gating electronics, and auxiliary I/O modules while providing internal overload protection against current surges.

Hardware Specifications

Parameter Specification
Model 3BHE035301R1002
Brand ABB
Product Type Power Modules
Input Voltage 100 to 240 VAC
Output Voltage 24 VDC
Output Current Up to 10 A
Operating Temp -20 to +60 deg C
Weight Standard Unitrol module weight (approx. 0.8 kg)
Power Consumption High efficiency conversion profile with internal overload protection

Deterministic Networks and Backplane Bus Communication Velocity

The power module maintains high-density voltage stability across internal backplane channels to prevent logic dropouts during grid disturbances or sudden load swings. Bus voltage regulation prevents ripple-induced propagation delays, ensuring high communication velocity for deterministically cycled control tasks across integrated PLC and excitation control cards. Onboard firmware flash compatibility remains maintained through regulated voltage execution during transient input fluctuations.

Frequently Asked Questions

Q: How does the overload protection operate when output current exceeds the 10 A limit?

A: The internal current-limiting circuit trips or folds back the 24 VDC output rail upon detecting an sustained overcurrent condition, protecting connected excitation logic cards from thermal overload.

Q: Can the module tolerate input voltage fluctuations without interrupting the 24 VDC output?

A: Yes, the wide input range of 100 to 240 VAC allows the module to maintain stable 24 VDC regulation during auxiliary AC bus voltage dips and brownouts.

Field Installation Guidelines

  1. Mounting Mechanics: Mount the module vertically on standard DIN rails or within designated Unitrol panel slots to optimize convective heat dissipation through ventilation slots.
  2. Earth Grounding: Connect the module chassis grounding terminal directly to the panel earth bus using a low-impedance copper conductor to suppress EMI transients.
  3. Input Wiring: Route 100-240 VAC main power leads through dedicated terminal blocks, maintaining physical separation from sensitive 24 VDC control lines and field communication cabling.
  4. Overcurrent Safeguards: Install external primary-side fuses in series with the AC input lines in accordance with cabinet short-circuit protection ratings.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
The Shift to Flexible IO Modules in Modern Industrial Automation

The Shift to Flexible IO Modules in Modern Industrial Automation

Traditional control systems rely on dedicated Input Output (IO) cards for industrial automation. Each conventional module processes a single signal type, such as Digital Input (DI), Digital Output (DO), Analog Input (AI), or Analog Output (AO). A standard 16-channel card accepts only one specific channel type across all ports. This inflexible hardware design often creates severe engineering bottlenecks during project execution. Engineers frequently must install entirely new cards to accommodate a single extra sensor. Consequently, late design changes increase control cabinet space requirements and drive up project costs.

Read more
DCS Commissioning Steps in Industrial Automation Projects

DCS Commissioning Steps in Industrial Automation Projects

Commissioning a Distributed Control System (DCS) represents a crucial milestone when deploying modern process automation infrastructure. Field engineers must execute systematic verification steps to transition complex control hardware from static installation to dynamic plant control. Proper commissioning ensures that controllers, I/O modules, network switches, and HMI software operate in strict compliance with engineering design specifications before introducing live process fluids.

Read more
PLC and DCS Control System Spares Strategy: Engineering Guidelines

PLC and DCS Control System Spares Strategy: Engineering Guidelines

Modern factory automation relies on high-speed fiber optic backbones to link distributed control systems across noise-intensive industrial environments. Unlike copper wiring, optical fibers transmit data via light pulses, making them completely immune to electromagnetic interference (EMI). Field engineers must master optical cable joining and fusion splicing techniques to guarantee low-loss data transmission across critical Programmable Logic Controller (PLC) and Distributed Control System (DCS) nodes.

Read more