Skip to content

What are you looking for?


You may also like

3BHB000652R0101 KU C720 AE01 | ABB | Inverter Power Board3BHB000652R0101 KU C720 AE01 | ABB | Inverter Power Board3BHB000652R0101 KU C720 AE01 | ABB | Inverter Power Board
3BHB000652R0101 KU C720 AE01 | ABB | Inverter Power Board
3BHB000652R0101 KU C720 AE01 | ABB | Inverter Power Board
3BHB000652R0101 KU C720 AE01 | ABB | Inverter Power Board

3BHB000652R0101 KU C720 AE01 | ABB | Inverter Power Board


Only 10 left - Selling fast

PRODUCT SKU : KU C720 AE01 3BHB000652R0101

PRODUCT TYPE : Power Supplies

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for gate driver signal isolation and intermediate power distribution in industrial drive systems, the ABB 3BHB000652R0101 KU C720 AE01 (KU C720 AE01 Inverter Power Board) provides direct physical/electrical execution.

Hardware Specifications

Parameter Specification
Model 3BHB000652R0101 KU C720 AE01
Brand ABB
Origin Switzerland
Weight 0.54 kg
Dimensions Standard ABB drive frame slot footprint
Operating Temp 0 to 55 deg C
Power Consumption Direct bus powered via drive backplane
Module Type Inverter Power / Interface Board
Tariff Code 85049090

Backplane Bus Communication Velocity and Firmware Flash Compatibility

The 3BHB000652R0101 KU C720 AE01 board processes high-frequency control signals without degrading backplane bus communication velocity across host inverter assemblies. Integrated hardware circuitry enforces deterministic field timing during power switching execution. Firmware flash compatibility ensures synchronized parameter translation between the main processor and secondary gate-driving stages, preventing transmission jitter and maintaining system I/O density scaling during transient load conditions.

Frequently Asked Questions

Q: What precautions are necessary regarding static discharge during installation of the 3BHB000652R0101 KU C720 AE01?

A: Personnel must wear a grounded ESD wrist strap and handle the module by its frame edges to protect sensitive surface-mount power electronics from electrostatic damage.

Q: How is power routed to the inverter power board?

A: Internal operating voltages are sourced directly through the motherboard backplane header connectors upon insertion into the drive chassis.

Q: What mounting procedure is required to secure the board within the drive housing?

A: The board slides along PCB alignment channels within the card cage and secures via metallic retaining screws to complete functional earth grounding.

Field Installation Guidelines

  1. Disconnect primary AC line power and 24 VDC auxiliary control power from the drive cabinet before servicing internal electronics.
  2. Verify that intermediate DC bus capacitors are discharged fully using a calibrated voltmeter before removing protective covers.
  3. Align the circuit card with the frame card guide channels and push firmly to engage the backplane pin assembly.
  4. Fasten all front-panel retention screws to secure the board against mechanical vibration and complete frame grounding paths.
  5. Re-apply auxiliary power and monitor diagnostic status indicators on the central drive display to verify nominal operation.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
The Shift to Flexible IO Modules in Modern Industrial Automation

The Shift to Flexible IO Modules in Modern Industrial Automation

Traditional control systems rely on dedicated Input Output (IO) cards for industrial automation. Each conventional module processes a single signal type, such as Digital Input (DI), Digital Output (DO), Analog Input (AI), or Analog Output (AO). A standard 16-channel card accepts only one specific channel type across all ports. This inflexible hardware design often creates severe engineering bottlenecks during project execution. Engineers frequently must install entirely new cards to accommodate a single extra sensor. Consequently, late design changes increase control cabinet space requirements and drive up project costs.

Read more
DCS Commissioning Steps in Industrial Automation Projects

DCS Commissioning Steps in Industrial Automation Projects

Commissioning a Distributed Control System (DCS) represents a crucial milestone when deploying modern process automation infrastructure. Field engineers must execute systematic verification steps to transition complex control hardware from static installation to dynamic plant control. Proper commissioning ensures that controllers, I/O modules, network switches, and HMI software operate in strict compliance with engineering design specifications before introducing live process fluids.

Read more
PLC and DCS Control System Spares Strategy: Engineering Guidelines

PLC and DCS Control System Spares Strategy: Engineering Guidelines

Modern factory automation relies on high-speed fiber optic backbones to link distributed control systems across noise-intensive industrial environments. Unlike copper wiring, optical fibers transmit data via light pulses, making them completely immune to electromagnetic interference (EMI). Field engineers must master optical cable joining and fusion splicing techniques to guarantee low-loss data transmission across critical Programmable Logic Controller (PLC) and Distributed Control System (DCS) nodes.

Read more