Skip to content

What are you looking for?


You may also like

1C31125G01 Digital Output Card | Westinghouse1C31125G01 Digital Output Card | Westinghouse1C31125G01 Digital Output Card | Westinghouse
1C31125G01 Digital Output Card | Westinghouse
1C31125G01 Digital Output Card | Westinghouse
1C31125G01 Digital Output Card | Westinghouse

1C31125G01 Digital Output Card | Westinghouse


Only 10 left - Selling fast

PRODUCT SKU : 1C31125G01

PRODUCT TYPE : Digital Output Cards

PRODUCT VENDOR : EMERSON


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for discrete signal transmission in Ovation control platforms, the Westinghouse 1C31125G01 (1C31125G01 Digital Output Card) provides direct physical electrical execution for switching field-side loads. The hardware functions as an interface for driving binary output commands from the controller to external actuators and relay systems.

Hardware Specifications

Parameter Specification
Model 1C31125G01
Brand Westinghouse
Origin United States
Weight 0.35 kg
Dimensions 12.1 cm x 5.1 cm x 16.6 cm
Operating Temp -40 to 70 deg C
Power Consumption 24 VDC
Module Type Digital Output Card

Process Instrumentation and Channel Integrity

The 1C31125G01 maintains output stability through integrated channel-to-channel isolation, preventing common-mode electrical noise and transients from propagating between discrete output loops. This isolation is necessary to preserve logic state integrity when driving inductive or capacitive field loads, ensuring that electrical faults on one output channel do not affect adjacent channels. The module facilitates seamless integration with 4-20 mA HART loop protocol diagnostics when deployed in compatible field device configurations, allowing for bi-directional status monitoring of the controlled elements.

Frequently Asked Questions (FAQ)

Q: Does the 1C31125G01 support hot-swapping within an active Ovation I/O rack?

A: The module supports hot-swap functionality; ensure that the I/O chassis backplane power is stable and that no external field voltage is being back-fed into the module output terminals during the replacement process.

Q: Are there restrictions regarding firmware compatibility for this output module?

A: Compatibility is dependent on the Ovation controller firmware version; ensure the system configuration file is updated to recognize the 1C31125G01 hardware ID before attempting communication.

Field Installation Guidelines

  1. Inspect the backplane connector slot for debris or pin deformation prior to module insertion.
  2. Align the card with the cabinet guide rails and insert until the connector is firmly seated against the backplane bus.
  3. Secure the module using the top and bottom captive fasteners to prevent mechanical displacement from industrial vibration.
  4. Terminate all output field wiring at the terminal block, utilizing shielded conductors to minimize electromagnetic interference (EMI).
  5. Bond the cable shield drain wire to the designated single-point ground bus in the cabinet to prevent the creation of ground loops.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more
Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Standard electromechanical relays provide basic electrical isolation between low-voltage control circuits and high-power output loads. A traditional switching relay features a magnetic coil driving mechanical Common (COM), Normally-Open (NO), and Normally-Closed (NC) contacts. However, standard relays pose severe functional risks when deployed in critical safety interlock circuits. High current inrush or mechanical wear can weld contacts together permanently. If contact welding occurs in an emergency stop circuit, pressing the button fails to halt hazardous machinery movements. Consequently, global functional safety standards prohibit standard relays for critical machine guarding functions.

Read more
Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Proper wire labeling forms the cornerstone of reliable control system installation and long-term maintenance. In complex industrial automation environments, technicians terminate thousands of conductor ends inside control panels, marshalling racks, and field junction boxes. Ferrules serve as individual tube-shaped sleeve markers slipped onto conductors before final termination. While technicians historically relied on pre-printed individual letter rings, modern control panel builders utilize automated ferrule printing machines. These thermal-transfer printers generate durable, single-sleeve heat-shrink tags directly matching approved wiring schematics, significantly accelerating cabinet assembly workflows.

Read more