Skip to content

What are you looking for?


You may also like

1C31125G01 Digital Output Card | Westinghouse1C31125G01 Digital Output Card | Westinghouse1C31125G01 Digital Output Card | Westinghouse
1C31125G01 Digital Output Card | Westinghouse
1C31125G01 Digital Output Card | Westinghouse
1C31125G01 Digital Output Card | Westinghouse

1C31125G01 Digital Output Card | Westinghouse


Only 10 left - Selling fast

PRODUCT SKU : 1C31125G01

PRODUCT TYPE : Digital Output Cards

PRODUCT VENDOR : EMERSON


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for discrete signal transmission in Ovation control platforms, the Westinghouse 1C31125G01 (1C31125G01 Digital Output Card) provides direct physical electrical execution for switching field-side loads. The hardware functions as an interface for driving binary output commands from the controller to external actuators and relay systems.

Hardware Specifications

Parameter Specification
Model 1C31125G01
Brand Westinghouse
Origin United States
Weight 0.35 kg
Dimensions 12.1 cm x 5.1 cm x 16.6 cm
Operating Temp -40 to 70 deg C
Power Consumption 24 VDC
Module Type Digital Output Card

Process Instrumentation and Channel Integrity

The 1C31125G01 maintains output stability through integrated channel-to-channel isolation, preventing common-mode electrical noise and transients from propagating between discrete output loops. This isolation is necessary to preserve logic state integrity when driving inductive or capacitive field loads, ensuring that electrical faults on one output channel do not affect adjacent channels. The module facilitates seamless integration with 4-20 mA HART loop protocol diagnostics when deployed in compatible field device configurations, allowing for bi-directional status monitoring of the controlled elements.

Frequently Asked Questions (FAQ)

Q: Does the 1C31125G01 support hot-swapping within an active Ovation I/O rack?

A: The module supports hot-swap functionality; ensure that the I/O chassis backplane power is stable and that no external field voltage is being back-fed into the module output terminals during the replacement process.

Q: Are there restrictions regarding firmware compatibility for this output module?

A: Compatibility is dependent on the Ovation controller firmware version; ensure the system configuration file is updated to recognize the 1C31125G01 hardware ID before attempting communication.

Field Installation Guidelines

  1. Inspect the backplane connector slot for debris or pin deformation prior to module insertion.
  2. Align the card with the cabinet guide rails and insert until the connector is firmly seated against the backplane bus.
  3. Secure the module using the top and bottom captive fasteners to prevent mechanical displacement from industrial vibration.
  4. Terminate all output field wiring at the terminal block, utilizing shielded conductors to minimize electromagnetic interference (EMI).
  5. Bond the cable shield drain wire to the designated single-point ground bus in the cabinet to prevent the creation of ground loops.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Step-by-Step System Cabinet Health Check Guide for PLC and DCS Infrastructure

Step-by-Step System Cabinet Health Check Guide for PLC and DCS Infrastructure

System cabinet health checks ensure long-term reliability in industrial automation. Preventative maintenance prevents hardware degradation, communication loss, and unplanned outages in control networks. This guide outlines the standard operating workflow for inspecting PLC and DCS cabinets to maintain peak performance.
Read more
Top 5 Operational Advantages of HMIs in Modern Factory Automation

Top 5 Operational Advantages of HMIs in Modern Factory Automation

HMIs bridge the gap between operators and complex industrial control networks. Modern factory automation relies on HMIs to deliver real-time visualization, precise control, and data analytics alongside PLC and DCS infrastructure. This technical guide explores five core operational benefits of deploying HMIs in manufacturing.
Read more
Importance of Safety Barriers in PLC and DCS Control Systems

Importance of Safety Barriers in PLC and DCS Control Systems

Process industries handle flammable gases and liquids, making electrical instrumentation a constant ignition risk. Engineers designing PLC and DCS networks must implement strict energy-limiting strategies. Intrinsic Safety barriers provide the critical interface that safeguards automation assets and prevents explosions.
Read more