Skip to content

What are you looking for?


You may also like

ICS Triplex T8480 Trusted TMR Analog Output ModuleICS Triplex T8480 Trusted TMR Analog Output ModuleICS Triplex T8480 Trusted TMR Analog Output Module
ICS Triplex T8480 Trusted TMR Analog Output Module
ICS Triplex T8480 Trusted TMR Analog Output Module
ICS Triplex T8480 Trusted TMR Analog Output Module

ICS Triplex T8480 Trusted TMR Analog Output Module


Only 10 left - Selling fast

PRODUCT SKU : T8480

PRODUCT TYPE : Analog Output Modules

PRODUCT VENDOR : ICS Triplex


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for high-integrity loop execution in safety-instrumented platforms, the ICS Triplex T8480 (T8480 Analog Output Module) provides direct physical/electrical execution. The hardware operates across 40 channels organized into 5 distinct power groups to drive 1 mA to 22 mA field loops under 20 VDC to 32 VDC backplane bus power.

Hardware Specifications

Parameter Specification
Model T8480
Brand ICS Triplex
Origin United Kingdom
Dimensions Standard T8100/T8300 Slot Form Factor
Operating Temp 0 deg C to +60 deg C
Power Consumption 22 W Backplane / 28 W System Supply Power Dissipation
Number of Outputs 40 Channels
Power Groups 5 Groups
Output Current Range 1 mA to 22 mA
Field Supply Voltage 18 VDC to 32 VDC (0.9 A max field supply current)
Isolation Voltage 50 V Reinforced continuous / 250 V Basic fault
Calibration Accuracy +/-0.1% FS (+25 deg C) / +/-0.25% FS (0 deg C to +60 deg C)
Step Response Time Less than 50 ms (1 mA to 20 mA step to 1% final value)
Short Circuit Protection 22 mA into 0 Ohm

High-Reliability Safety Control & TMR Architecture

The T8480 incorporates triple modular redundancy (TMR) 2oo3 architecture to satisfy SIL3 certification requirements in emergency shutdown and safety-critical execution loops. Signal routing across the inter-module bus (IMB) maintains complete fail-safe state execution through dedicated fault isolation boundaries. Galvanic isolation rated at 50 V continuous reinforced insulation protects channel groups against common-mode electrical faults, suppressing inter-channel disturbance and preventing uncommanded signal shifts during system transients.

Frequently Asked Questions

Q: How does the T8480 handle output current transients during hot-swap module replacement?

A: During standby swap conditions, bump fault leakage is strictly constrained to a maximum of +/-350 uA for up to 7 seconds, with peak transient excursions capped at +/-10 mA for less than 50 ms.

Q: Are the internal output fuses field-replaceable by maintenance staff?

A: No. The internal fusing components are integrated within the module assembly and are not user serviceable.

Q: What slot locations in the system rack accommodate the T8480 module?

A: The module is engineered specifically for installation in designated T8100 and T8300 I/O module chassis slots.

Field Installation Guidelines

  1. Disconnect or isolate the 18 VDC to 32 VDC field power supply before wiring field terminal blocks to prevent transient arcing across power group boundaries.
  2. Route field current loop wiring through shielded twisted-pair cables, terminating shields to the system earth busbar to maintain +/-0.1% full scale calibration accuracy.
  3. Ensure the module is fully aligned and latched into the T8100 or T8300 slot backplane connectors to maintain adequate galvanic insulation and backplane current transfer.
  4. Verify field wiring load impedance does not force current limits below the required 1 mA threshold during loop commissioning.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Demystifying Signal Isolators: Operating Principles, Architectural Types, and Industrial Applications

Demystifying Signal Isolators: Operating Principles, Architectural Types, and Industrial Applications

Industrial automation systems rely on pristine analog signal transmission across complex control loops. Instrument technicians and system integrators frequently deploy signal isolators to maintain signal integrity between field sensors and control platforms. Eliminating electrical noise, ground loops, and high-voltage transients protects delicate PLC, DCS, and SCADA input channels from permanent damage.

Read more
Demystifying Industrial Control Systems: Comparing PLC, DCS, RTU, SCADA, and PAC

Demystifying Industrial Control Systems: Comparing PLC, DCS, RTU, SCADA, and PAC

Modern factory automation relies on distinct control architectures to manage complex process environments efficiently. Control engineers often evaluate PLC, DCS, RTU, SCADA, and PAC platforms when designing industrial infrastructure. Understanding the functional boundaries of each technology ensures optimal system performance, high availability, and long-term cost efficiency.

Read more
Evaluating Industrial Automation: Architectural Benefits and Operational Challenges

Evaluating Industrial Automation: Architectural Benefits and Operational Challenges

Modern manufacturing relies heavily on advanced industrial automation to streamline production cycles and maintain precise process execution. Automated control systems, programmable logic controllers (PLCs), and distributed control systems (DCS) replace repetitive manual intervention on shop floors. Evaluating the balance between operational gains and capital investment remains essential for engineering leaders planning smart factory upgrades.

Read more