Product Details

Configured for wind turbine control and monitoring in turbine management systems, the Woodward LR20025 (LR20025 Multifunction Relay) provides direct electrical execution of voltage and current sensing via CAN bus communication.

Hardware Specifications

Parameter Specification
Model LR20025
Brand Woodward
Origin Not specified
Weight 2.00 lbs
Dimensions 96 mm x 72 mm x 130 mm
Voltage Sensing 250-690 VAC, 50/60 Hz
Current Sensing 0.5-5 A

Actuator Loop Feedback Response and Thermal Heat Sink Dissipation Profiles

The LR20025 integrates directly into the turbine control architecture, utilizing CAN bus protocol to report status and receive operational commands. The internal sensing circuitry is calibrated to manage high-voltage inputs (250-690 VAC) and current inputs (0.5-5 A) while maintaining signal accuracy. Thermal heat sink dissipation profiles for the relay enclosure are designed to support continuous operation under typical turbine nacelle temperature fluctuations. The relay maintains a stable actuator loop feedback response by processing electrical parameters and providing real-time data back to the primary PLC, ensuring the turbine system remains within programmed operational limits.

Frequently Asked Questions

Q: Can the LR20025 be replaced by other relay models if the original is unavailable?

A: The LR20025 (MFR13) can be replaced by the MFR300 (Part number 8444-1093), which offers similar functionality for wind turbine applications. Ensure the existing CAN bus addressing and terminal wiring maps are verified before commissioning the replacement unit.

Q: What are the primary communication requirements for integration with a PLC?

A: The device communicates via CAN bus protocol. Ensure the PLC interface supports the relevant CAN bus baud rate and message structure required for relay monitoring and control.

Field Installation Guidelines

  • Mounting: Secure the relay within the turbine control panel using the specified 96 x 72 mm cutout. Ensure the 130 mm depth allows for adequate cable routing and clearance from high-voltage power components.
  • Wiring: Connect sensing inputs for voltage (250-690 VAC) and current (0.5-5 A) to the designated terminals. Use appropriate gauge wire rated for the maximum expected current and voltage levels.
  • Communication: Establish the CAN bus link to the PLC. Ensure proper termination of the CAN bus network at both ends to prevent data packet corruption and reflection errors.
  • Isolation: Maintain physical and electrical separation between low-voltage CAN bus signal lines and high-voltage AC sensing circuits to prevent noise injection and protect the communication interface.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the appropriate cabling infrastructure is critical for the success of any industrial automation project. Improper cable selection often leads to signal degradation, system instability, and costly downtime. As an automation engineer, I frequently see projects compromised by poor cabling choices in harsh industrial environments. This guide simplifies the complex landscape of cabling to help you make informed decisions for your PLC, DCS, and control systems.

Read more
Preventing Spurious Trips in Emergency Stop Systems: A Technical Guide

Preventing Spurious Trips in Emergency Stop Systems: A Technical Guide

In industrial automation, the Emergency Stop (E-Stop) pushbutton is the ultimate safety line. However, relying on a single Normally-Closed (NC) contact can sometimes lead to unexpected spurious trips. As a control systems engineer, I have seen these nuisance trips halt entire production lines, causing significant downtime. Understanding why these components fail and how to implement robust architecture is essential for any reliable DCS or PLC-based safety system.

Read more
Sequencing Induction Motor Control with PLC Logic: Best Practices

Sequencing Induction Motor Control with PLC Logic: Best Practices

In modern industrial automation, controlling a group of induction motors requires precision and safety. Uncontrolled simultaneous startup of multiple large motors often causes significant voltage dips, potentially triggering protective trips. Therefore, implementing a sequential startup and shutdown strategy is essential. This approach minimizes inrush current and ensures the system operates within established power constraints. A robust PLC program serves as the ideal engine for orchestrating these sequences.

Read more