Product Details

Configured for hardware integration in control networks, the Woodward 8923-1262 (8923-1262 Installation Kit) provides direct electrical execution of communication interface expansion for easYgen-3x00 and RP3000 series platforms.

Hardware Specifications

Parameter Specification
Model 8923-1262
Brand Woodward
Origin Not specified
Weight 0.2 kg
Operating Temp -40 deg C to +70 deg C
Operating Voltage 24 VDC
Communication Protocols Modbus RTU, Ethernet/IP

Actuator Loop Feedback Response and Thermal Heat Sink Dissipation Profiles

The 8923-1262 kit facilitates the expansion of communication interfaces for localized control systems. The assembly is designed to maintain signal integrity for Modbus RTU and Ethernet/IP protocols, ensuring deterministic data exchange between the controller and auxiliary devices. Within the control cabinet environment, the thermal heat sink dissipation profiles of the included components are optimized for operation within the -40 to +70 deg C range. The kit minimizes impedance mismatches in communication lines, thereby supporting stable actuator loop feedback response when integrated into larger prime mover management networks.

Frequently Asked Questions

Q: Does this installation kit require external power configuration beyond the 24 VDC supply?

A: The kit operates on a 24 VDC input. Ensure that the supply is regulated and filtered to prevent common-mode noise from affecting the communication protocol latencies on the Ethernet/IP or Modbus RTU links.

Q: Is the kit compatible with redundant communication architectures?

A: The kit supports standard Modbus RTU and Ethernet/IP connectivity. Integration into redundant architectures depends on the primary controller's native port configuration and the specific network topology employed.

Field Installation Guidelines

  • Mounting: Ensure all kit components are secured to the chassis using the provided mounting hardware. Verify that the assembly does not obstruct natural airflow within the cabinet.
  • Wiring: Utilize shielded cabling for all communication connections to maintain protocol integrity. Terminate shields according to the specific ground reference requirements of the controller backplane.
  • Voltage Verification: Confirm the 24 VDC power source is stable before engaging the connection to the control series (easYgen-3x00 or RP3000).
  • Protocol Setup: After physical integration, configure the communication baud rate and network addressing within the controller software to match the specific Modbus or Ethernet/IP network parameters.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the appropriate cabling infrastructure is critical for the success of any industrial automation project. Improper cable selection often leads to signal degradation, system instability, and costly downtime. As an automation engineer, I frequently see projects compromised by poor cabling choices in harsh industrial environments. This guide simplifies the complex landscape of cabling to help you make informed decisions for your PLC, DCS, and control systems.

Read more
Preventing Spurious Trips in Emergency Stop Systems: A Technical Guide

Preventing Spurious Trips in Emergency Stop Systems: A Technical Guide

In industrial automation, the Emergency Stop (E-Stop) pushbutton is the ultimate safety line. However, relying on a single Normally-Closed (NC) contact can sometimes lead to unexpected spurious trips. As a control systems engineer, I have seen these nuisance trips halt entire production lines, causing significant downtime. Understanding why these components fail and how to implement robust architecture is essential for any reliable DCS or PLC-based safety system.

Read more
Sequencing Induction Motor Control with PLC Logic: Best Practices

Sequencing Induction Motor Control with PLC Logic: Best Practices

In modern industrial automation, controlling a group of induction motors requires precision and safety. Uncontrolled simultaneous startup of multiple large motors often causes significant voltage dips, potentially triggering protective trips. Therefore, implementing a sequential startup and shutdown strategy is essential. This approach minimizes inrush current and ensures the system operates within established power constraints. A robust PLC program serves as the ideal engine for orchestrating these sequences.

Read more