Skip to content

What are you looking for?


You may also like

IM/C1900INS ABB Commander 1900 Circular Chart RecorderIM/C1900INS ABB Commander 1900 Circular Chart RecorderIM/C1900INS ABB Commander 1900 Circular Chart Recorder
IM/C1900INS ABB Commander 1900 Circular Chart Recorder
IM/C1900INS ABB Commander 1900 Circular Chart Recorder
IM/C1900INS ABB Commander 1900 Circular Chart Recorder

IM/C1900INS ABB Commander 1900 Circular Chart Recorder


Only 10 left - Selling fast

PRODUCT SKU : IM/C1900INS

PRODUCT TYPE : Circular Chart Recorders

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The ABB IM/C1900INS (part number 01A75661R000), also cataloged as the IM/C1900INS Circular Chart Recorder, operates as a dedicated hardware component for universal analog signal acquisition and physical chart trace generation within ABB Commander 1900 system platforms. The unit processes field inputs and drives pen displacement and circular paper rotation on a 190 mm (7.5 in) format.

Hardware Specifications

Parameter Specification
Model IM/C1900INS (Part Number: 01A75661R000)
Brand ABB
Origin United Kingdom
Weight 4.5 kg
Dimensions 420 mm x 297 mm x 160 mm (W x H x D)
Operating Temp -10 to +55 deg C
Power Consumption 24 VDC or 100-240 VAC supply options
Chart Diameter 190 mm (7.5 in) compact circular chart
Recording Accuracy +/-0.1% of span
Chart Speed Programmable (1 hour to 32 days per revolution)
Input Signal Types Thermocouples, RTDs, VDC, 4-20 mA, Digital inputs
Serial Interface RS485 Modbus RTU protocol
Enclosure Protection NEMA 4X / IP66 front panel washdown rating
Product Type Circular Chart Recorders

Channel Isolation and Input Signal Conditioning

The IM/C1900INS utilizes high-resolution analog input conditioning circuits to isolate universal field inputs prior to digital processing. Channel isolation eliminates ground potential differences across RTD, thermocouple, and 4-20 mA transmitter loops. The onboard microprocessor executes linearization algorithms to convert field measurements into servo pen movements and transmits digitized values across the RS485 Modbus serial bus.

Frequently Asked Questions

Q: Does the IM/C1900INS support hot-swapping or field maintenance while powered?

A: No. Terminal connections and internal board access require complete isolation of the 100-240 VAC or 24 VDC main supply to prevent electrical shock or equipment damage.

Q: How is the RS485 Modbus network bus terminated at the recorder?

A: A 120 ohm line termination resistor must be connected across the differential A/B communication terminals on the final physical device along the RS485 daisy-chain trunk.

Field Installation Guidelines

  1. Mount the unit in a panel cutout matching the 420 mm x 297 mm chassis enclosure dimensions.
  2. Ensure the front door seal compresses uniformly against the cabinet face to preserve the NEMA 4X / IP66 washdown protection rating.
  3. Route signal inputs and RS485 serial communication cables in grounded metallic conduits separate from high-voltage AC power lines.
  4. Connect a dedicated protective earth (PE) grounding cable to the main chassis terminal bolt prior to energizing the instrument.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more
Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling cabinets serve as the vital interface between field instrumentation and control room electronics in modern process facilities. Regular preventive maintenance of these cabinets ensures signal integrity across programmable logic controllers (PLCs), distributed control systems (DCS), and emergency shutdown (ESD) networks. System technicians must execute structured inspection protocols to mitigate environmental risks, identify loose wiring, and maintain continuous operational readiness.

Read more
Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Industry 4.0 integrates digital intelligence into field operations, transforming factory automation landscapes worldwide. Spatial technologies—specifically Augmented Reality (AR) and Virtual Reality (VR)—redefine how engineers interact with industrial control systems. By bridging computer-generated CAD models with real-time operational technology (OT) data, immersive displays enable intuitive monitoring, rapid diagnostics, and safer maintenance across complex processing facilities.

Read more