The ABB IM/C1900INS (part number 01A75661R000), also cataloged as the IM/C1900INS Circular Chart Recorder, operates as a dedicated hardware component for universal analog signal acquisition and physical chart trace generation within ABB Commander 1900 system platforms. The unit processes field inputs and drives pen displacement and circular paper rotation on a 190 mm (7.5 in) format.

Hardware Specifications

Parameter Specification
Model IM/C1900INS (Part Number: 01A75661R000)
Brand ABB
Origin United Kingdom
Weight 4.5 kg
Dimensions 420 mm x 297 mm x 160 mm (W x H x D)
Operating Temp -10 to +55 deg C
Power Consumption 24 VDC or 100-240 VAC supply options
Chart Diameter 190 mm (7.5 in) compact circular chart
Recording Accuracy +/-0.1% of span
Chart Speed Programmable (1 hour to 32 days per revolution)
Input Signal Types Thermocouples, RTDs, VDC, 4-20 mA, Digital inputs
Serial Interface RS485 Modbus RTU protocol
Enclosure Protection NEMA 4X / IP66 front panel washdown rating
Product Type Circular Chart Recorders

Channel Isolation and Input Signal Conditioning

The IM/C1900INS utilizes high-resolution analog input conditioning circuits to isolate universal field inputs prior to digital processing. Channel isolation eliminates ground potential differences across RTD, thermocouple, and 4-20 mA transmitter loops. The onboard microprocessor executes linearization algorithms to convert field measurements into servo pen movements and transmits digitized values across the RS485 Modbus serial bus.

Frequently Asked Questions

Q: Does the IM/C1900INS support hot-swapping or field maintenance while powered?

A: No. Terminal connections and internal board access require complete isolation of the 100-240 VAC or 24 VDC main supply to prevent electrical shock or equipment damage.

Q: How is the RS485 Modbus network bus terminated at the recorder?

A: A 120 ohm line termination resistor must be connected across the differential A/B communication terminals on the final physical device along the RS485 daisy-chain trunk.

Field Installation Guidelines

  1. Mount the unit in a panel cutout matching the 420 mm x 297 mm chassis enclosure dimensions.
  2. Ensure the front door seal compresses uniformly against the cabinet face to preserve the NEMA 4X / IP66 washdown protection rating.
  3. Route signal inputs and RS485 serial communication cables in grounded metallic conduits separate from high-voltage AC power lines.
  4. Connect a dedicated protective earth (PE) grounding cable to the main chassis terminal bolt prior to energizing the instrument.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Redundant Automation Systems: Ensuring Continuous Uptime in Critical Control Infrastructure

Redundant Automation Systems: Ensuring Continuous Uptime in Critical Control Infrastructure

System reliability directly determines operational profitability across high stakes process industries. Modern industrial automation platforms must eliminate single points of failure to prevent catastrophic shutdowns. Deploying fault tolerant architecture safeguards complex facilities against unexpected hardware glitches, network disruptions, and maintenance outages.

Read more
Understanding Types of Noise in Electronic Circuits and Control Systems

Understanding Types of Noise in Electronic Circuits and Control Systems

Signal integrity directly determines measurement accuracy and loop stability across industrial automation environments. Electronic noise introduces unwanted stochastic interference into analog loops, sensor feedback lines, and digital fieldbus networks. Understanding how intrinsic electronic noise and external electromagnetic interference manifest allows control engineers to optimize signal conditioning and shield sensitive instrumentation effectively.

Read more
Why 24V DC Power Supplies Standardize Modern Industrial Automation

Why 24V DC Power Supplies Standardize Modern Industrial Automation

Industrial control cabinets worldwide rely on 24V DC as the universal power standard for field instrumentation, sensors, and controllers. Walk into any manufacturing plant, and you will find PLCs, human-machine interfaces (HMIs), and smart actuators running on extra-low voltage DC. Standardizing on 24V DC enhances operational safety, lowers cabinet footprint, and maintains steady control performance across factory networks.

Read more