Skip to content

What are you looking for?


You may also like

IC693CHS392 | GE Fanuc Series 90-30 10-Slot Expansion BaseplateIC693CHS392 | GE Fanuc Series 90-30 10-Slot Expansion BaseplateIC693CHS392 | GE Fanuc Series 90-30 10-Slot Expansion Baseplate
IC693CHS392 | GE Fanuc Series 90-30 10-Slot Expansion Baseplate
IC693CHS392 | GE Fanuc Series 90-30 10-Slot Expansion Baseplate
IC693CHS392 | GE Fanuc Series 90-30 10-Slot Expansion Baseplate

IC693CHS392 | GE Fanuc Series 90-30 10-Slot Expansion Baseplate


Only 10 left - Selling fast

PRODUCT SKU : IC693CHS392

PRODUCT TYPE : Expansion Baseplate

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview

The IC693CHS392 by GE Fanuc is a 10-slot expansion baseplate for Series 90-30 PLC systems, designed to extend I/O capacity and support additional modules with a maximum of seven CPUs per system and a 25-pin D-shell expansion port for interconnection.

Technical Specifications

  • Manufacturer: GE Fanuc Emerson

  • Model / Part Number: IC693CHS392

  • Product Type: Expansion Baseplate

  • Series: Series 90-30

  • Weight: 2.06 lbs (0.94 kg)

  • Voltage Input: 5 VDC

  • Current Draw: 150 mA

  • Number of I/O Slots: 10

  • CPU Slots: None

  • Slot Assignments: Slots 1–5 for I/O or option modules

  • Power Supply Slot: Dedicated for power supply module

  • Expansion Slot: 25-pin D-shell female connector

  • Maximum CPUs Supported: 7

  • Maximum Expansion Cable Length: 50 ft (15 m)

  • Internal Power Consumption: 150 mA at 5 VDC

  • Installation Environment: Indoor only

  • Mounting: Panel mounting

  • Product Lifecycle Status: Discontinued / Obsolete

Applications

  • Expanding I/O capacity of Series 90-30 PLC systems

  • Integrating additional modules in modular control systems

  • Supporting large-scale automation setups with multiple CPUs

FAQ

Q: How many CPU modules can the IC693CHS392 support?
A: It supports up to seven CPU modules per system.

Q: What is the maximum expansion cable length?
A: The expansion cable can be up to 50 feet (15 meters) long.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Industry 4.0 integrates digital intelligence into field operations, transforming factory automation landscapes worldwide. Spatial technologies—specifically Augmented Reality (AR) and Virtual Reality (VR)—redefine how engineers interact with industrial control systems. By bridging computer-generated CAD models with real-time operational technology (OT) data, immersive displays enable intuitive monitoring, rapid diagnostics, and safer maintenance across complex processing facilities.

Read more
Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Factory Acceptance Testing (FAT) and Site Acceptance Testing (SAT) serve as critical quality assurance gateways in complex industrial control systems. Both procedures verify that programmable logic controllers (PLCs), distributed control systems (DCS), and associated field devices meet strict functional specifications. However, executing these tests effectively requires clear delineation between off-site staging and final field commissioning.

Read more
Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial automation relies heavily on robust networking infrastructure to connect programmable logic controllers (PLCs), distributed control systems (DCS), and human-machine interfaces (HMIs). Modern factory automation environments generate vast amounts of real-time operational data across deterministic networks. Understanding the structural differences between hubs, switches, and routers ensures optimal traffic segmentation, minimizes latency, and maintains high network availability.

Read more