Only 10 left - Selling fast

PRODUCT SKU : IS200TREGH1BDB

PRODUCT TYPE : Turbine Termination Board

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The IS200TREGH1BDB serves as a primary Trip Emergency Termination Board within the General Electric Mark VI control family. This Brand New original component provides the physical and electrical interface required to execute emergency shutdown sequences for utility-scale gas and steam turbines. It manages critical trip signals by coordinating high-capacity relays and surge suppression components, ensuring the control system maintains absolute authority over the turbine’s mechanical safety valves.

Technical Specifications

The IS200TREGH1BDB utilizes a robust hardware layout to handle high-current switching and transient protection.

Component / Feature Specification Details
Manufacturer General Electric (GE)
Product Series Mark VI
Board Type Trip Emergency Termination (TREG)
Relay Configuration 12 Large Relays (Arranged in pairs)
Surge Protection 10 Red Metal Oxide Varistors (MOVs)
Capacitance 4 Large Yellow Capacitors
Terminal Capacity 48 Silver Terminals (Across 2 long blocks)
Connectivity 3 Jack Connector Ports (Pin-style)
Dimensions 30.5 cm x 22.9 cm x 5.1 cm
Weight 0.5 kg (1.1 lbs)

Engineering Advantages

  • Failsafe Relay Logic: Twelve large relays, arranged in pairs, provide redundant switching paths for the turbine trip solenoids. This configuration prevents a single relay failure from causing an accidental trip or, more critically, failing to close during an emergency shutdown.

  • Transient Surge Suppression: Ten integrated Metal Oxide Varistors (MOVs) actively clamp high-voltage spikes caused by inductive load switching. This protection layer shields the sensitive Mark VI control processors from back-EMF, extending the lifespan of the entire I/O rack.

  • High-Density Field Wiring: Two 24-point terminal blocks provide 48 total silver-plated connection points. These blocks accommodate heavy-gauge field wiring, ensuring secure, low-resistance termination for critical safety circuits.

  • Direct I/O Interfacing: Three jack connector ports allow for rapid connection to the Mark VI I/O packs. This design eliminates complex point-to-point internal wiring, reducing the risk of installation errors and simplifying maintenance during planned outages.

FAQs

  • Is this IS200TREGH1BDB board a brand new unit?

    Yes. We supply this board as 100% Brand New original GE factory stock. It arrives in the original manufacturer’s packaging with all factory inspection seals intact to guarantee field reliability.

  • Can this board support Triple Modular Redundant (TMR) systems?

    The TREG series boards typically support TMR applications by interfacing with three separate I/O packs. The three connector ports on the IS200TREGH1BDB allow the board to receive "voted" trip signals from the R, S, and T control cores.

  • What is the function of the red MOVs on the board?

    The red MOVs (Metal Oxide Varistors) protect the board’s circuitry from voltage surges. They absorb excess energy when switching inductive loads, such as large turbine trip solenoids, preventing damage to the relays and upstream control electronics.

  • Do I need special tools to connect field wiring to the silver terminals?

    Standard industrial screwdrivers suffice for the terminal blocks. However, GE recommends using ferruled wire ends to ensure maximum contact surface area and to prevent wire fraying within the high-vibration environment of a turbine control cabinet.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Remote Terminal Units: The Core of SCADA and Telemetry Systems

Understanding Remote Terminal Units: The Core of SCADA and Telemetry Systems

In industrial automation, engineers often debate the choice between a Programmable Logic Controller (PLC) and...
Read more
Ultimate Guide to Schneider Electric PLCs: Selecting Control Systems for Small to Medium Automation

Ultimate Guide to Schneider Electric PLCs: Selecting Control Systems for Small to Medium Automation

Schneider Electric remains a dominant force in global industrial automation, delivering robust control systems across diverse sectors. For control engineers, selecting the right programmable logic controller (PLC) requires balancing budget, communication ports, and processing power. This technical breakdown explores Schneider’s small and medium portfolio, offering field-tested insights to help you optimize your next factory automation project.

Read more
Essential Maintenance Guide for PLC, DCS, and ESD Marshalling Cabinets

Essential Maintenance Guide for PLC, DCS, and ESD Marshalling Cabinets

Marshalling cabinets serve as the vital interface between field instrumentation and your core control systems. In large-scale industrial automation, these panels house the intricate wiring for PLC, DCS, and Emergency Shutdown (ESD) systems. Regular, systematic health checks are non-negotiable to ensure operational reliability and prevent costly unplanned downtime.

Read more