Emerson KJ2004X1-BA1 DeltaV Remote Interface UnitEmerson KJ2004X1-BA1 DeltaV Remote Interface UnitEmerson KJ2004X1-BA1 DeltaV Remote Interface Unit
Emerson KJ2004X1-BA1 DeltaV Remote Interface Unit
Emerson KJ2004X1-BA1 DeltaV Remote Interface Unit
Emerson KJ2004X1-BA1 DeltaV Remote Interface Unit

Emerson KJ2004X1-BA1 DeltaV Remote Interface Unit


Only 10 left - Selling fast

PRODUCT SKU : KJ2004X1-BA1

PRODUCT TYPE : Remote Interface Unit

PRODUCT VENDOR : EMERSON


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for remote data concentration and localized bus expansion in DeltaV electronic marshalling systems, the Emerson KJ2004X1-BA1 (KJ2004X1-BA1 Remote Interface Unit) provides direct physical/electrical execution. This hardware assembly coordinates multi-drop communication packet routing and translates serialized transport streams from extended I/O subsystems back to the centralized distributed controller architecture.

Hardware Specifications

Parameter Specification
Model KJ2004X1-BA1
Brand Emerson
Origin USA
Weight 2.5 kg (Shipping Weight)
Dimensions Standard DeltaV carrier system module footprint
Operating Temp -40 deg C to +70 deg C
Power Consumption 5 VDC at 300 mA maximum, 3.3 VDC at 500 mA maximum (Local Bus Power)
Ingress Protection IP 20 Rating
Shock Resistance 10g 1/2 sine wave for 11 ms
Vibration Resistance 1 mm peak-to-peak from 2 to 13.2 Hz; 0.7g from 13.2 to 150 Hz
Airborne Contaminants ISA-S71.04-1985 Class G3 compliance
Relative Humidity 5% to 95% non-condensing

Channel-To-Channel Isolation and DCS Synchronization

Mechanical execution of this remote interface link relies on dedicated galvanic boundaries to maintain strict signal processing synchronization across wide network areas. The inner circuit topology enforces channel-to-channel isolation between the external communication line inputs and the local system logic power rails. This layout isolates the core distributed control architecture from high-frequency electromagnetic interference, ground potential loops, and localized transient faults occurring on the 4-20 mA HART loop protocol field tracks connected to the peripheral marshalling rows.

Frequently Asked Questions

Q: Does this remote interface hardware support hot-swap extraction under live backplane power?

A: Yes. The module is engineered for online hot-swap operations. The structural terminal design dampens bus voltage fluctuations during live mating cycles, preventing active logic failures or communications interruptions on neighboring slots.

Q: What are the distinct voltage demands supplied through the local bus system?

A: The hardware partitions its power allocation into dual paths, drawing a maximum of 300 mA at 5 VDC alongside a maximum of 500 mA at 3.3 VDC from the local bus carrier infrastructure to run the digital logic circuits.

Field Installation Guidelines

  • Module Carrier Mounting: Position the remote interface unit vertically over the matching slot guide of the local assembly baseplate. Apply downward pressure until the mechanical mounting clips are completely seated to guarantee electrical connection stability.

  • Grounding Array Parameters: Connect all communication cable screens directly to the main marshalling cabinet ground bus bar. Verify a single-point grounding layout to protect against low-frequency common-mode noise across the remote network infrastructure.

  • Cabinet Environment Controls: When deploying the IP 20 rated chassis in locations with Class G3 airborne contaminants, mount the hardware inside a sealed, positive-pressure industrial enclosure to prevent humidity condensation and sulfur gas corrosion.

  • Cable Routing Distance: Keep low-voltage serial and Ethernet communications cables separated from high-current AC motor control lines by a minimum physical distance of 300 mm within the panel tracking to minimize inductive signal cross-talk.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
PLC vs. PAC: Navigating Selection in Modern Industrial Automation

PLC vs. PAC: Navigating Selection in Modern Industrial Automation

Selecting the right controller is a fundamental decision in industrial automation. While the lines between Programmable Logic Controllers (PLC) and Programmable Automation Controllers (PAC) often blur, understanding their core architectural differences is essential for system reliability. Both controllers serve as the brain of control systems, yet their specific capabilities dictate their suitability for various factory automation tasks.

Read more
Transforming Textile Manufacturing: The Strategic Integration of Industrial Automation and AI

Transforming Textile Manufacturing: The Strategic Integration of Industrial Automation and AI

The textile industry stands at a critical technological crossroads. Legacy operations must now embrace digital transformation to remain competitive in a global market. By integrating advanced industrial automation—ranging from PLC-controlled machinery to sophisticated AI-driven analytics—manufacturers can significantly boost productivity, minimize material waste, and elevate overall product quality.

Read more
Navigating Industrial Communication Protocols: A Technical Guide for Modern PLCs

Navigating Industrial Communication Protocols: A Technical Guide for Modern PLCs

In the realm of industrial automation, the Programmable Logic Controller (PLC) serves as the brain of the factory floor. However, its true power is unlocked through robust communication protocols. These digital pathways ensure seamless data exchange between controllers, sensors, and enterprise-level management systems.

Read more