Skip to content

What are you looking for?


You may also like

Emerson EPRO PR9268/301-000 Electrodynamic Vibration TransducerEmerson EPRO PR9268/301-000 Electrodynamic Vibration TransducerEmerson EPRO PR9268/301-000 Electrodynamic Vibration Transducer
Emerson EPRO PR9268/301-000 Electrodynamic Vibration Transducer
Emerson EPRO PR9268/301-000 Electrodynamic Vibration Transducer
Emerson EPRO PR9268/301-000 Electrodynamic Vibration Transducer

Emerson EPRO PR9268/301-000 Electrodynamic Vibration Transducer


Only 10 left - Selling fast

PRODUCT SKU : PR9268/301-000

PRODUCT TYPE : Vibration Sensors

PRODUCT VENDOR : EMERSON


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for seismic vibration acquisition in rotating machinery, the Emerson EPRO PR9268/301-000 (PR9268/301-000) Electrodynamic Vibration Transducer provides direct electrical execution of velocity-based vibration monitoring.

Hardware Specifications

Parameter Specification
Model PR9268/301-000
Brand Emerson EPRO
Operating Temp -50 deg C to +120 deg C
Power Consumption Passive (no external power)
Sensitivity 20 mV/mm/s (+/- 5%)
Frequency Range 10 to 1000 Hz
Measurement Range 0 to 100 mm/s (peak)

Process Control and DCS Connectivity

The PR9268 series sensors integrate with standard DCS and PLC interfaces capable of processing low-impedance analog voltage inputs. To ensure measurement integrity, channel-to-channel isolation must be maintained within the input interface of the monitoring system to prevent ground loops that could introduce signal drift. These sensors utilize Faraday's law of induction, generating an analog signal proportional to vibration velocity, which is compatible with 4-20 mA HART loop protocol conditioning modules. Impedance matching between the 600 Ohm coil and the signal conditioner is necessary to ensure the frequency response remains within the rated 10-1000 Hz window.

Frequently Asked Questions

Q: Does the sensor require an external power supply to function?

A: No. The PR9268/301-000 is a passive electrodynamic transducer that generates its own output signal based on seismic movement. It does not require a supply voltage, but must be connected to a signal conditioner with appropriate input impedance.

Q: What is the impact of mounting torque on the sensor's frequency response?

A: The M10 x 1.5 threaded stud must be tightened to achieve a rigid mechanical coupling. Improper torque may result in mechanical resonance between the sensor housing and the machine casing, which can cause significant attenuation or amplification of high-frequency vibration signals.

Field Installation Guidelines

  1. Secure the sensor to a flat, machined surface on the bearing housing or casing using the M10 x 1.5 mounting stud to ensure rigid high-frequency transmission.
  2. Verify the mechanical alignment to ensure the sensor axis is oriented correctly for the specific vibration mode being monitored.
  3. Terminate signal leads at the signal conditioner input using shielded twisted-pair cabling; connect the shield to a common instrument ground to minimize electromagnetic noise.
  4. Confirm the cable length is minimized to prevent capacitive loading, which can affect the high-frequency response characteristic.
  5. Conduct a physical check during initial startup to verify signal output polarity and circuit continuity before the machinery reaches operating speed.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Engineering a Process Control System Philosophy: Principles and Operational Impact

Engineering a Process Control System Philosophy: Principles and Operational Impact

A Process Control System (PCS) Philosophy serves as the foundational blueprint for modern plant engineering. During the design and construction phases, this document establishes clear guidelines for instrumentation and control (I&C) teams. Consequently, a well-defined philosophy directly dictates overall operational stability, maintenance efficiency, and future expansion capabilities across heavy process industries.

Read more
Engineering MCC Signal Interface Terminations in Modern Process Automation

Engineering MCC Signal Interface Terminations in Modern Process Automation

Industrial manufacturing plants rely on Motor Control Centers (MCC) to drive critical electrical loads. Plant engineers must interface these MCC motor starters and drives with central control systems. Standardizing the Signal Interface Termination (SIT) architecture ensures seamless command delivery and feedback monitoring between field equipment and process automation platforms.

Read more
Layer-2 vs. Layer-3 Network Switches in Industrial Control Systems

Layer-2 vs. Layer-3 Network Switches in Industrial Control Systems

Modern factory automation relies heavily on robust Industrial Ethernet communications. Control system engineers deploy managed Ethernet switches to connect programmable logic controllers (PLCs), distributed control systems (DCS), human-machine interfaces (HMIs), and field I/O devices. Selecting between Layer-2 and Layer-3 switching architecture directly impacts network throughput, routing capabilities, and overall cybersecurity defense in operational technology (OT) networks.