Configured for discrete signal acquisition in DeltaV I/O subsystems, the Emerson KL3003X1-BA1 (KL3003X1-BA1) Digital Input CHARM (Characterization Module) provides direct physical/electrical execution of dry contact sensing.
Hardware Specifications
| Parameter | Specification |
| Model | KL3003X1-BA1 |
| Brand | Emerson |
| Origin | USA |
| Weight | 0.04 kg (0.08 lbs) |
| Dimensions | Standard CHARM form factor |
| Operating Temp | Not specified |
| Power Consumption | Bus Power 32 mA at 6.3 VDC |
| Input Type | Dry Contact |
| Field Circuit | 10 mA at 24 VDC |
Process Control: Channel-to-Channel Isolation
The KL3003X1-BA1 CHARM provides channel-to-channel isolation within the DeltaV I/O carrier, preventing electrical interference between individual field loops. This isolation is integral to the CHARM architecture, ensuring that faults in a single dry contact loop do not propagate to the common bus or affect adjacent input channels. The module processes field-side dry contact status and provides a 24 VDC wetting voltage for the field loop, converting the signal for transmission across the I/O bus. Proper termination of the dry contact loop at the terminal block is required to maintain the integrity of the galvanic isolation barrier.
Frequently Asked Questions (FAQ)
Q: What is the purpose of the CHARM module in the DeltaV system?
A: The Characterization Module (CHARM) allows for per-channel I/O type assignment. The KL3003X1-BA1 specifically converts a dry contact field input into a digital signal that the DeltaV controller can process, eliminating the need for traditional multi-channel I/O cards.
Q: Is this module hot-swappable?
A: Yes. The CHARM architecture supports hot-swapping. The module can be removed and replaced while the carrier is energized without affecting the operation of other channels in the same carrier.
Field Installation Guidelines
-
Installation: Align the module with the carrier slot and press firmly until the locking mechanism engages. Ensure the module is seated fully to maintain backplane communication contact.
-
Wiring: Dry contact field wiring must be terminated on the CHARM terminal block. Use shielded twisted pair cable for field wiring to mitigate induced noise, and ensure the shield is grounded at the designated cabinet grounding bar.
-
Grounding: The carrier system must be properly bonded to the system common earth ground. This is vital for the effective operation of the channel-to-channel isolation barrier and protection against electrostatic discharge.
-
Verification: Verify that the field loop resistance matches the required specifications for dry contact closure before applying power to the carrier. Ensure no foreign voltage is present on the dry contact field lines.
Additional Information
- 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
- 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
- 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
- Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
- Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
- Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.