Skip to content

What are you looking for?


You may also like

CI541-DP 1SAP224100R0001 PROFIBUS Interface Communication Module | ABBCI541-DP 1SAP224100R0001 PROFIBUS Interface Communication Module | ABBCI541-DP 1SAP224100R0001 PROFIBUS Interface Communication Module | ABB
CI541-DP 1SAP224100R0001 PROFIBUS Interface Communication Module | ABB
CI541-DP 1SAP224100R0001 PROFIBUS Interface Communication Module | ABB
CI541-DP 1SAP224100R0001 PROFIBUS Interface Communication Module | ABB

CI541-DP 1SAP224100R0001 PROFIBUS Interface Communication Module | ABB


Only 10 left - Selling fast

PRODUCT SKU : CI541-DP 1SAP224100R0001

PRODUCT TYPE : Interface Communication Module

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview

The ABB CI541-DP (1SAP224100R0001) is a PROFIBUS communication interface module designed for ABB’s S500 I/O system. It functions as a PROFIBUS-DP slave and provides local analog and digital I/O capabilities. With a modular and expandable design, it supports up to ten additional I/O modules, making it ideal for distributed automation networks that require scalable performance, reliable communication, and easy integration with ABB controllers or third-party PLCs.

Technical Specifications

  • Manufacturer: ABB

  • Model Number: CI541-DP

  • Part Number: 1SAP224100R0001

  • Product Type: PROFIBUS Interface Communication Module

  • Function: PROFIBUS slave interface with onboard analog and digital I/Os

  • Communication Interface: RS-485 (PROFIBUS-DP)

  • Analog Inputs: 4 channels (Voltage, Current, RTD)

  • Analog Outputs: 2 channels (Voltage, Current)

  • Digital Inputs: 8 channels, 24 VDC

  • Digital Outputs: 8 channels, 24 VDC, 0.5 A transistor outputs

  • Input Voltage: 24 VDC

  • Input Current: 5 mA per channel

  • Signal Delay: Adjustable from 0.1 to 32 ms

  • Output Current Capacity: 0.5 A per channel (transistor type)

  • Expandable I/O Modules: Up to 10 additional S500 I/O units

  • Electrical Isolation: Galvanic isolation between field and logic

  • Mounting Type: DIN rail

  • Protection Rating: IP20

  • Dimensions (H × W × D): 76 × 67.5 × 62 mm

  • Net Weight: 0.134 kg

  • Gross Weight: 0.158 kg

Key Features

  • Integrated PROFIBUS-DP slave for distributed automation control

  • Combination of analog and digital I/O channels for flexible configurations

  • Scalable design allowing extension with up to ten I/O modules

  • Compact form factor optimized for cabinet installations

  • Reliable 24VDC transistor outputs for industrial signal control

  • Galvanic isolation ensures communication stability and equipment protection

Application Scenarios

The CI541-DP module is designed for industrial environments requiring reliable field communication and signal processing, including:

  • Process automation: integration with ABB AC500 and S500 systems

  • Manufacturing lines: distributed control and I/O expansion

  • Power generation and utilities: plant communication and control systems

  • Water and wastewater treatment: remote station data exchange

  • Chemical and pharmaceutical production: precision I/O monitoring and control

FAQ

Q: What communication protocol does the CI541-DP use?
A: It uses the PROFIBUS-DP protocol with an RS-485 interface.

Q: Can the CI541-DP operate independently?
A: It operates as a PROFIBUS-DP slave and requires a master controller such as ABB AC500 or compatible DCS.

Q: How many I/O channels are built into the module?
A: The module includes 4 analog inputs, 2 analog outputs, 8 digital inputs, and 8 digital outputs.

Q: Can additional modules be added?
A: Yes, it supports expansion with up to 10 S500 I/O modules.

Q: What is the output type?
A: Outputs are transistor-based and rated for 0.5 A per channel at 24VDC.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding VFD Mechanical Brake Logic and Control in Industrial Automation

Understanding VFD Mechanical Brake Logic and Control in Industrial Automation

Variable Frequency Drives (VFDs) play a crucial role in modern industrial automation by controlling motor speed, torque, and acceleration. However, high-inertia loads and vertical lifting systems require precise mechanical braking logic to ensure operational safety and prevent equipment damage.

Read more
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more