PRODUCT SKU : 1900/27-01

PRODUCT TYPE : Vibration Monitors

PRODUCT VENDOR : Bently Nevada


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Bently Nevada 1900/27-01, also cataloged as the 1900/27 Vibration Monitor, operates as a dedicated hardware component for single-channel vibration signal conditioning and machinery protection within 1900 Series monitoring platforms.

Hardware Specifications

Parameter Specification
Model 1900/27-01
Brand Bently Nevada
Origin USA
Weight 0.64 kg (1.40 lbs)
Dimensions Standard 1900 Series monitor footprint
Operating Temp -30 deg C to +65 deg C (-22 deg F to +149 deg F)
Power Consumption 60 mA maximum current draw
Input Voltage 110 VAC, 50/60 Hz
Channel Configuration Single-channel dynamic vibration input
Alarm Functions Adjustable time delay trip logic

Dynamic Vibration Processing and Gap Voltage Validation

The 1900/27-01 conditions continuous dynamic signals originating from proximity probe transducers or velocity sensors. Internal processing circuits apply precise eddy-current probe scaling to compute true peak-to-peak shaft vibration amplitudes or overall casing vibration levels. During commissioning and system health monitoring, DC gap voltage validation verifies proper transducer mechanical bias voltage, ensuring target proximity sensors remain centered within their linear dynamic range. Configurable time delay alarms prevent false machinery trips resulting from transient operational shocks during startup or load changes.

Frequently Asked Questions

Q: How does the adjustable time delay feature function on the 1900/27-01 monitor relay logic?

A: The onboard time delay circuit delays relay contact activation for a preset duration following a threshold breach to prevent spurious trips caused by short-duration dynamic spikes.

Q: What power input supply parameters are required to operate the 1900/27-01 module?

A: The module requires an AC line supply of 110 VAC at 50/60 Hz, drawing a maximum operating current of 60 mA.

Field Installation Guidelines

  1. Ensure main power is disconnected from the 1900 Series panel before installing or wiring the monitor unit.
  2. Mount the 1900/27-01 securely into its designated chassis slot or panel cutout using original mounting hardware.
  3. Connect incoming 110 VAC power conductors to the assigned AC power input terminals.
  4. Terminate transducer signal and common leads at the channel input terminals, using shielded twisted-pair cabling.
  5. Ground signal cable drain wires at a single termination point on the system chassis ground bar to suppress ground loop noise pickup.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
Mastering Modern Industrial Joystick Controls in Heavy Automation

Mastering Modern Industrial Joystick Controls in Heavy Automation

Industrial joysticks play a pivotal role in human-machine interaction across heavy material handling and mobile hydraulics. These tactile controllers translate complex operator movements into precise electrical signals for PLCs, motion controllers, and DCS networks. Consequently, selecting and installing the right joystick architecture ensures operator safety, reduces fatigue, and optimizes equipment performance.

Read more
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more