Skip to content

What are you looking for?


You may also like

21000-16-10-00-090-03-02 Proximity Probe Housing Assemblies | Bently Nevada21000-16-10-00-090-03-02 Proximity Probe Housing Assemblies | Bently Nevada21000-16-10-00-090-03-02 Proximity Probe Housing Assemblies | Bently Nevada
21000-16-10-00-090-03-02 Proximity Probe Housing Assemblies | Bently Nevada
21000-16-10-00-090-03-02 Proximity Probe Housing Assemblies | Bently Nevada
21000-16-10-00-090-03-02 Proximity Probe Housing Assemblies | Bently Nevada

21000-16-10-00-090-03-02 Proximity Probe Housing Assemblies | Bently Nevada


Only 10 left - Selling fast

PRODUCT SKU : 21000-16-10-00-090-03-02

PRODUCT TYPE : Proximity Probe Housings

PRODUCT VENDOR : Bently Nevada


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Bently Nevada 21000-16-10-00-090-03-02, also cataloged as the 21000 Housing Assembly, operates as a dedicated hardware component for mechanical transducer enclosure and environmental sealing within 3300 and 3500 Machinery Protection Systems.

Suffix Breakdown & Model Matrix

Option Field Code Configuration Detail
Probe Option 16 3/8-24 UNF reverse mount proximity probe
Probe Cable Length Option 10 1.0 m (39 in) probe cable length
Standoff Adapter Option 00 No standoff adapter
Probe Penetration Option 090 9.0 in sleeve length
Fittings Option 03 One 3/4-14 NPT plug and one 3/4-14 NPT thread
Agency Approval Option 02 Multiple approvals (CSA, ATEX, IECEx)

Hardware Specifications

Parameter Specification
Model 21000-16-10-00-090-03-02
Brand Bently Nevada
Origin USA
Weight 0.36 kg
Dimensions 12.5 cm x 2.1 cm x 10.5 cm
Operating Temp -40 deg C to +120 deg C (-40 deg F to +248 deg F)
Power Consumption Passive mechanical housing assembly
Ingress Protection Rating IP66
Body Material Aluminum housing body with 304 stainless steel sleeve
Probe Interface 3/8-24 UNF reverse mount proximity probe
Mounting Thread 3/4-14 NPT

Transducer Mounting and Gap Voltage Validation

The 21000-16-10-00-090-03-02 housing assembly positions reverse-mount eddy-current probes through casing walls while isolating probe electronics from process fluids and debris. Accurate probe positioning through the 304 stainless steel sleeve allows fine mechanical adjustment to satisfy gap voltage validation targets (-10 VDC baseline) at room temperature. Proper rigid attachment prevents housing resonance under high dynamic machine movement, preserving linear eddy-current probe scaling and preventing phase distortion during rotor dynamics measurement.

Frequently Asked Questions

Q: How is environmental sealing maintained around the internal probe cable entry?

A: The aluminum housing body and terminal seals meet IP66 ingress protection standards, sealing out dust and high-pressure water jets when installed with NPT thread sealant.

Q: Can the internal sleeve length be adjusted in the field?

A: No, the penetration option code specifies a factory-machined sleeve length; field mechanical alterations risk degrading housing structural integrity and environmental sealing ratings.

Field Installation Guidelines

  1. Inspect the housing threads and O-ring seals for physical damage or contamination before mounting to the machine casing.
  2. Apply industrial-grade thread sealant to the 3/4-14 NPT mounting threads, ensuring at least 5 full threads of engagement into the tapping boss.
  3. Thread the reverse-mount proximity probe into the internal sleeve until the probe tip reaches the calculated mechanical offset from the target shaft.
  4. Connect the probe leads to the extension cable and verify that the output reads nominal -10 VDC gap voltage prior to final sealing.
  5. Tighten the housing cover to compress the environmental seal and install the 3/4-14 NPT plug on unused conduit ports.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Step-by-Step System Cabinet Health Check Guide for PLC and DCS Infrastructure

Step-by-Step System Cabinet Health Check Guide for PLC and DCS Infrastructure

System cabinet health checks ensure long-term reliability in industrial automation. Preventative maintenance prevents hardware degradation, communication loss, and unplanned outages in control networks. This guide outlines the standard operating workflow for inspecting PLC and DCS cabinets to maintain peak performance.
Read more
Top 5 Operational Advantages of HMIs in Modern Factory Automation

Top 5 Operational Advantages of HMIs in Modern Factory Automation

HMIs bridge the gap between operators and complex industrial control networks. Modern factory automation relies on HMIs to deliver real-time visualization, precise control, and data analytics alongside PLC and DCS infrastructure. This technical guide explores five core operational benefits of deploying HMIs in manufacturing.
Read more
Importance of Safety Barriers in PLC and DCS Control Systems

Importance of Safety Barriers in PLC and DCS Control Systems

Process industries handle flammable gases and liquids, making electrical instrumentation a constant ignition risk. Engineers designing PLC and DCS networks must implement strict energy-limiting strategies. Intrinsic Safety barriers provide the critical interface that safeguards automation assets and prevents explosions.
Read more