Skip to content

What are you looking for?


You may also like

ABB REJ603BB401NN3XE | Relion 605 Series | Self-Powered Feeder Protection RelayABB REJ603BB401NN3XE | Relion 605 Series | Self-Powered Feeder Protection RelayABB REJ603BB401NN3XE | Relion 605 Series | Self-Powered Feeder Protection Relay
ABB REJ603BB401NN3XE | Relion 605 Series | Self-Powered Feeder Protection Relay
ABB REJ603BB401NN3XE | Relion 605 Series | Self-Powered Feeder Protection Relay
ABB REJ603BB401NN3XE | Relion 605 Series | Self-Powered Feeder Protection Relay

ABB REJ603BB401NN3XE | Relion 605 Series | Self-Powered Feeder Protection Relay


Only 10 left - Selling fast

PRODUCT SKU : REJ603BB401NN3XE REJ603

PRODUCT TYPE : Feeder Protection Relay

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The ABB REJ603BB401NN3XE is a self-powered feeder protection relay developed for secondary distribution networks in both utility and industrial environments. As part of the Relion 605 series, it provides dependable protection without requiring auxiliary power, making it particularly suitable for unmanned substations and ring main units (RMU).

Key Features

  • Self-powered operation utilizing current transformers (CTs) for energy supply, eliminating external power sources

  • Protection functions including non-directional overcurrent protection (low/high set) and earth-fault protection (low/high set)

  • Selectable time characteristics with definite time and inverse time settings, supporting multiple standard and fuse curves

  • Fast startup response ensuring immediate protection availability

  • Compact design optimized for secondary distribution switchgear and RMU installations

Technical Specifications

  • Manufacturer ABB

  • Model REJ603BB401NN3XE

  • Series Relion 605

  • Product Type Self-Powered Feeder Protection Relay

  • Operation Mode Self-powered via CTs

  • Protection Functions Overcurrent (low/high set), Earth-fault (low/high set)

  • Time Characteristics Definite time, inverse time, fuse characteristics

  • Application Scope Secondary distribution networks, RMUs, unmanned substations

  • Startup Quick energization and protection response

Application Scenarios

  • Secondary distribution networks requiring reliable feeder protection without auxiliary power

  • Unmanned substations where compact and autonomous relays are essential

  • Ring main units (RMU) needing integrated feeder and earth-fault protection

FAQ

Q: Does the REJ603 require an external power supply?  A: No, it is fully self-powered using current transformers.

Q: What type of protection functions are included?  A: It supports non-directional overcurrent and earth-fault protection with selectable settings.

Q: Is the REJ603 suitable for RMU applications?  A: Yes, its compact design and self-powered operation make it ideal for RMUs.

Similar Model Comparison

  • REJ603BB401NN3XE: Self-powered, compact, optimized for RMU and secondary distribution

  • REF615: Advanced feeder protection with IEC 61850 communication support

  • REJ601: Basic self-powered feeder protection with limited functionality compared to REJ603

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding VFD Mechanical Brake Logic and Control in Industrial Automation

Understanding VFD Mechanical Brake Logic and Control in Industrial Automation

Variable Frequency Drives (VFDs) play a crucial role in modern industrial automation by controlling motor speed, torque, and acceleration. However, high-inertia loads and vertical lifting systems require precise mechanical braking logic to ensure operational safety and prevent equipment damage.

Read more
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more