Skip to content

What are you looking for?


You may also like

ABB 3BHL001089P0001 Type 8225 Conductivity MeterABB 3BHL001089P0001 Type 8225 Conductivity MeterABB 3BHL001089P0001 Type 8225 Conductivity Meter
ABB 3BHL001089P0001 Type 8225 Conductivity Meter
ABB 3BHL001089P0001 Type 8225 Conductivity Meter
ABB 3BHL001089P0001 Type 8225 Conductivity Meter

ABB 3BHL001089P0001 Type 8225 Conductivity Meter


Only 10 left - Selling fast

PRODUCT SKU : 3BHL001089P0001

PRODUCT TYPE : Conductivity Meters

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The ABB 3BHL001089P0001, also cataloged as the Type 8225 Conductivity Meter, operates as a dedicated hardware component for inline electrolytic conductivity sensing and liquid process signal acquisition within industrial automation networks. The instrument measures solution conductance, converting physical sensor cell signals into calibrated analog data for system controllers.

Hardware Specifications

Parameter Specification
Model 3BHL001089P0001 (Type 8225)
Brand ABB
Origin Switzerland
Weight 0.863 kg
Dimensions Standard inline analytical transmitter housing
Operating Temp 0 to +55 deg C
Power Consumption System transmitter loop powered
Product Type Conductivity Meters
System Platform ABB Analytical Instrumentation
Customs Tariff Code 90278011

Backplane Bus Communication Velocity & Deterministic Processing

The Type 8225 conductivity meter interfaces with control platforms via high-speed loop channels, providing deterministic data updates for real-time process loops. Microprocessor-based signal conditioning circuits ensure firmware flash compatibility across controller revisions, maintaining minimal signal propagation delay and high communication velocity during continuous liquid measurement cycles.

Frequently Asked Questions

Q: What primary parameter is measured by the 3BHL001089P0001 Type 8225 assembly?

A: The instrument measures liquid electrolytic conductivity, generating calibrated electrical signals for analytical process loops.

Q: Is hot-swapping supported for the Type 8225 conductivity meter?

A: No, transmitter loop power must be de-energized and liquid line pressure relieved before servicing or removing the sensor assembly to avoid electrical faults or fluid leakage.

Q: How is signal integrity preserved against industrial electromagnetic interference?

A: Sensor leads and output signal wiring utilize shielded twisted-pair cables with drain wire termination grounded to the chassis earth terminal.

Field Installation Guidelines

  • Isolate line pressure and shut off power feeds to the transmitter prior to mounting or wiring the meter.
  • Mount the transmitter housing securely to the piping socket or mounting bracket to prevent mechanical vibration stress.
  • Connect all signal and power wiring using shielded cable, ensuring the cable shield is connected directly to the cabinet ground point.
  • Verify that cable gland entry points are fully tightened to maintain enclosure ingress protection against humidity and dust.
  • Calibrate cell constants and temperature compensation parameters according to standard laboratory solutions before placing the unit into active loop control.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Comprehensive Guide to Servo Motor Drive Control Techniques in Industrial Automation

Comprehensive Guide to Servo Motor Drive Control Techniques in Industrial Automation

Precision motion control systems drive high-throughput manufacturing across modern industrial automation environments. Unlike standard induction motors running on basic variable frequency drives, servo motor systems deliver sub-millimeter positioning accuracy and fast dynamic response.

Read more
Industrial PLC Communication Protocols: A Comprehensive Engineering Guide

Industrial PLC Communication Protocols: A Comprehensive Engineering Guide

Modern factory automation relies heavily on industrial communication protocols to connect field instruments, controllers, and enterprise networks. Beyond traditional hardwired I/O, robust communication networks allow programmable logic controllers (PLCs) to exchange telemetry, diagnostic data, and control commands efficiently across complex architectures.

Read more
Understanding PLC Digital Output Types: Relay, Transistor, and Triac Explained

Understanding PLC Digital Output Types: Relay, Transistor, and Triac Explained

Programmable Logic Controllers (PLCs) form the backbone of modern industrial automation systems. They interface directly with field devices such as solenoid valves, indicator lights, motor starters, and interposing relays. Selecting the correct digital output module ensures high system availability and long hardware service life.

Read more