Product Details

The ABB 35ST90 GJR5144900R0001, also cataloged as the 35ST90 Front Connector Module, operates as a dedicated hardware component for field signal termination and wiring interface consolidation within ABB Symphony, Master, and Freelance DCS platforms. Constructed from corrosion-resistant brass alloy with an IP67 M12 connector type, it routes up to 16 discrete or analog channels across a wire gauge range of 0.14 mm2 to 1.0 mm2. The assembly operates at a rated current of 10 A and voltages up to 100 V DC across ambient operating temperatures from -40 deg C to +70 deg C.

Hardware Specifications

Parameter Specification
Model 35ST90 (GJR5144900R0001)
Base Model 35ST90
Brand ABB
Origin Sweden
Weight 0.45 kg
Dimensions 35 x 90 x 50 mm
Operating Temp -40 deg C to +70 deg C
Power Consumption Passive Component / 10 A Current Limit
Material Corrosion-resistant Brass Alloy
Connector Type M12, IP67 rated
Connection Count 16-pin
Operating Voltage Up to 100 V DC
Wire Gauge 0.14 mm2 - 1.0 mm2
System Compatibility ABB Symphony, Master, Freelance DCS

Backplane Bus Communication Velocity and Density Scaling

The passive physical interconnection design preserves high backplane bus communication velocity and signal integrity when scaling I/O density on active rack cards. Contact resistance across all 16 pins is minimized to eliminate signal distortion during high-frequency data sampling. Direct terminal engagement ensures full electrical compatibility across system processor flash firmware updates without requiring modifications to field terminal wiring.

Frequently Asked Questions

Q: What are the maximum wire gauge and current limits per terminal pin?

A: The connector accepts conductor cross-sections between 0.14 mm2 and 1.0 mm2 (26 AWG to 18 AWG) and supports a maximum current rating of 10 A per pin at up to 100 V DC.

Q: How is the IP67 ingress protection rating maintained at the field interface?

A: IP67 protection requires fully tightening the M12 screw coupling until seated against the integral rubber gasket, preventing dust and water entry into the 16-pin contact array.

Field Installation Guidelines

  • Strip field conductors to 6-8 mm, ensuring individual wire strands are fully inserted into terminal clamping points without stray conductors.
  • Align the 16-pin guide key with the mating I/O module faceplate before pressing the connector into place.
  • Hand-tighten the M12 metallic coupling ring to lock the connector body onto the card frame and ensure grounding continuity.
  • Route field wiring through strain-relief channels inside the control cabinet to avoid mechanical tension on the screw terminals.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling cabinets serve as the vital interface between field instrumentation and control room electronics in modern process facilities. Regular preventive maintenance of these cabinets ensures signal integrity across programmable logic controllers (PLCs), distributed control systems (DCS), and emergency shutdown (ESD) networks. System technicians must execute structured inspection protocols to mitigate environmental risks, identify loose wiring, and maintain continuous operational readiness.

Read more
Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Industry 4.0 integrates digital intelligence into field operations, transforming factory automation landscapes worldwide. Spatial technologies—specifically Augmented Reality (AR) and Virtual Reality (VR)—redefine how engineers interact with industrial control systems. By bridging computer-generated CAD models with real-time operational technology (OT) data, immersive displays enable intuitive monitoring, rapid diagnostics, and safer maintenance across complex processing facilities.

Read more
Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Factory Acceptance Testing (FAT) and Site Acceptance Testing (SAT) serve as critical quality assurance gateways in complex industrial control systems. Both procedures verify that programmable logic controllers (PLCs), distributed control systems (DCS), and associated field devices meet strict functional specifications. However, executing these tests effectively requires clear delineation between off-site staging and final field commissioning.

Read more