Skip to content

What are you looking for?


You may also like

ABB 1SAP217000R0001 TU532 Terminal UnitABB 1SAP217000R0001 TU532 Terminal UnitABB 1SAP217000R0001 TU532 Terminal Unit
ABB 1SAP217000R0001 TU532 Terminal Unit
ABB 1SAP217000R0001 TU532 Terminal Unit
ABB 1SAP217000R0001 TU532 Terminal Unit

ABB 1SAP217000R0001 TU532 Terminal Unit


Only 10 left - Selling fast

PRODUCT SKU : TU532 1SAP217000R0001

PRODUCT TYPE : Terminal Base Units

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for physical field wiring termination and module interfacing in S500 I/O systems, the ABB 1SAP217000R0001 (TU532 Terminal Unit) provides direct physical/electrical execution. The hardware connects 230 VAC discrete signals and relay expansion modules to the system backplane through spring-terminal connection points.

Hardware Specifications

Parameter Specification
Model 1SAP217000R0001 (TU532)
Brand ABB
Origin Germany / Standard ABB Distribution
Weight 0.164 kg (Net) / 0.194 kg (Gross)
Dimensions 67.5 mm x 135 mm x 28 mm (W x H x D)
Operating Temp 0 to +60 deg C (Storage: -40 to +70 deg C)
Power Consumption Passive Backplane Route (24 VDC Supply Voltage Input)
Terminal Connection Type Spring Terminals
Module Compatibility 230 VAC Inputs / Outputs & Relay Modules
Degree of Protection IP20

Backplane Bus Communication Velocity Licences & Power Routing

The base unit integrates passive bus lines that interface S500 I/O modules directly with the controller backplane. Embedded conductor paths support backplane bus communication velocity Licences required for real-time deterministic cyclic data transfer across the local expansion cluster. Galvanic routing paths isolate high-voltage 230 VAC switching potentials on the field terminal side from internal 24 VDC backplane logic circuitry, maintaining noise immunity and structural signal integrity during fast transient events.

Frequently Asked Questions

Q: Can I replace an S500 I/O module mounted on the TU532 without disconnecting field wiring?

A: Yes. The TU532 terminal unit retains all spring-terminal field connections on its base frame, allowing plugged I/O modules to be unlatched and swapped without disturbing field wiring looms.

Q: What conductor wire cross-sections are supported by the spring terminals?

A: The spring-clamp terminals accept standard solid or ferruled flexible copper conductors up to 2.5 mm sq for AC power and field signal routing.

Q: Does the TU532 carry an IP protection rating for wet environments?

A: The unit carries an IP20 rating and must be installed inside an enclosure providing adequate ingress protection against conductive dust, moisture, and debris.

Field Installation Guidelines

  • Mount the terminal unit onto a standard 35 mm DIN rail by snapping the rear locking mechanism firmly into place before inserting I/O modules.
  • Strip field conductor insulation to specified length (typically 9 to 10 mm) before inserting into spring clamp terminals using a flat-head screwdriver.
  • Ensure proper grounding of the DIN rail to cabinet PE bus to establish a low-impedance ground path for high-voltage isolation circuits.
  • Verify isolation of 230 VAC field supply lines prior to wiring terminal connections or inserting/removing adjacent expansion hardware.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Preventing Emergency Stop Spurious Trips in Industrial Control Systems

Preventing Emergency Stop Spurious Trips in Industrial Control Systems

Emergency Stop pushbuttons use Normally Closed contacts for fail-safe safety, but mechanical wear can cause costly spurious trips. This technical guide examines E-Stop contact failure root causes, redundant hardware setups, PLC logic monitoring, and maintenance strategies to maximize plant availability.

Read more
Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Industrial manufacturing requires continuous uptime to prevent equipment damage. Unlike AC power, 24V DC circuits seamlessly integrate with UPS units and battery banks. During main grid failures, a 24V DC backup system instantly maintains PLC memory, instrument loops, and critical safety valves without interruption.

Read more
Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

The Site Acceptance Test (SAT) represents the definitive handover stage in industrial automation projects. While the Factory Acceptance Test confirms cabinet hardware assembly off-site, the SAT validates real-world performance under live site conditions. Consequently, a structured execution strategy prevents equipment damage and guarantees seamless integration into plant operations.

Read more