Product Overview

The Yokogawa AAI135-H50 serves as a high-performance analog input interface within the CENTUM distributed control system (DCS) architecture. This module processes up to 16 channels of isolated 4 to 20 mA DC signals, converting field data into digital information for the control processor. Even as some older series face manufacturer discontinuation, we provide this unit in 100% brand new, original factory condition to ensure the longevity of your existing control infrastructure.

Technical Specifications

This module provides critical signal isolation to protect the system bus from field-side electrical surges and interference.

Feature Specification
Manufacturer Yokogawa
Model Number AAI135-H50
Input Signal 4 to 20 mA DC
Max Input Current 25 mA
Withstanding Voltage 500 V AC
Number of Channels 16-channel, isolated
Weight 0.55 lbs (approx. 0.25 kg)
System Compatibility CENTUM CS 3000 / CENTUM VP

Part Number Breakdown: AAI135-H50

Yokogawa part numbers follow a strict functional logic. The AAI135 series is specifically designed for standard current inputs:

  • AAI135: Base Model (Isolated Current Input, 4 to 20 mA, 16-channel).

  • -H: High-speed / High-reliability industrial specification.

  • 5: Standard type (Non-explosion protected).

  • 0: Basic connection type (Terminal block or standard interface).

Engineering Advantages

  • Signal Isolation Excellence: The 500 V AC withstanding voltage ensures that ground loops or field faults do not damage the expensive central processor units.

  • Legacy System Support: As a critical component for many established plants, the AAI135-H50 allows for the maintenance of legacy DCS systems without the need for a full, multi-million dollar system migration.

  • Precision Data Acquisition: High-resolution A/D conversion provides the accuracy required for sensitive chemical, oil, and gas process loops.

  • Hardened Industrial Build: Designed to operate in high-temperature and high-vibration environments typical of industrial rack rooms, ensuring a long MTBF (Mean Time Between Failure).

FAQs

  • Can I use the AAI135-H50 to replace an older AAI135-S series module?

    Yes, the "H" version generally offers superior performance and can replace standard versions, provided the system configuration recognizes the updated hardware ID.

  • Is this unit truly brand new if the manufacturer has discontinued the series?

    Yes. We specialize in sourcing "New Old Stock" (NOS) that remains in its original factory-sealed packaging. These units have never been installed or energized.

  • What is the primary difference between the AAI135 and the AAI835?

    The AAI135 focuses on standard isolation requirements (500 V AC), whereas the AAI835 typically offers higher isolation ratings (1500 V AC) for more electrically "noisy" environments.

  • Does this module support HART communication?

    The AAI135 is a standard analog input module. If your application requires HART protocol pass-through for instrument diagnostics, you may need to consider the AAI143 or AAI841 series.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
PLC vs. PAC: Navigating Selection in Modern Industrial Automation

PLC vs. PAC: Navigating Selection in Modern Industrial Automation

Selecting the right controller is a fundamental decision in industrial automation. While the lines between Programmable Logic Controllers (PLC) and Programmable Automation Controllers (PAC) often blur, understanding their core architectural differences is essential for system reliability. Both controllers serve as the brain of control systems, yet their specific capabilities dictate their suitability for various factory automation tasks.

Read more
Transforming Textile Manufacturing: The Strategic Integration of Industrial Automation and AI

Transforming Textile Manufacturing: The Strategic Integration of Industrial Automation and AI

The textile industry stands at a critical technological crossroads. Legacy operations must now embrace digital transformation to remain competitive in a global market. By integrating advanced industrial automation—ranging from PLC-controlled machinery to sophisticated AI-driven analytics—manufacturers can significantly boost productivity, minimize material waste, and elevate overall product quality.

Read more
Navigating Industrial Communication Protocols: A Technical Guide for Modern PLCs

Navigating Industrial Communication Protocols: A Technical Guide for Modern PLCs

In the realm of industrial automation, the Programmable Logic Controller (PLC) serves as the brain of the factory floor. However, its true power is unlocked through robust communication protocols. These digital pathways ensure seamless data exchange between controllers, sensors, and enterprise-level management systems.

Read more