Skip to content

What are you looking for?


You may also like

2711-K10C10| Allen Bradley PanelView 1000 Standard Operator Terminal2711-K10C10| Allen Bradley PanelView 1000 Standard Operator Terminal2711-K10C10| Allen Bradley PanelView 1000 Standard Operator Terminal
2711-K10C10| Allen Bradley PanelView 1000 Standard Operator Terminal
2711-K10C10| Allen Bradley PanelView 1000 Standard Operator Terminal
2711-K10C10| Allen Bradley PanelView 1000 Standard Operator Terminal

2711-K10C10 | Allen Bradley PanelView 1000 Standard Operator Terminal


Only 10 left - Selling fast

PRODUCT SKU : 2711-K10C10

PRODUCT TYPE : Operator Terminal

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview  The Allen Bradley PanelView 1000 series 2711-K10C10 operator terminal is a discontinued model from the PanelView Standard family. It was designed to provide reliable operator interface functionality with a keypad-based input system and a full-color active matrix display. Despite its lifecycle status, it remains relevant for legacy systems requiring replacement or maintenance.

Key Specifications

  • Brand Allen Bradley

  • Series PanelView 1000 Standard

  • Product Type Operator Terminal

  • Model/Part Number 2711-K10C10

  • Weight 10.69 lbs (4.85 kg)

  • Display Type Color active matrix

  • Display Size 10.1 in. (211 x 158 mm / 8.3 x 6.2 in.)

  • Resolution 640 x 480 pixels

  • Backlight LED, 50,000 hours half-life

  • Keypad Assembly 16 function keys (F1–F16)

  • Application Memory 310 KB runtime memory, 1008 KB nonvolatile memory

  • Communication Ports DeviceNet, RS-232 (printer)

  • Input Voltage Range 85–264 V AC

  • Input Frequency 47–63 Hz

  • Input Power 85–264 V AC

  • Status Indicators COMM: Green, Fault: Red

  • Enclosure Ratings NEMA Type 12/13, 4X (indoor use only), IP54, IP65

  • Operating Temperature 0–60 °C (32–140 °F)

  • Product Lifecycle Status Discontinued/Obsolete

Application Scenarios  The 2711-K10C10 was widely used in industrial automation systems requiring operator input and monitoring. Its rugged enclosure made it suitable for indoor environments with dust or moisture protection needs. Typical applications included machine-level control, process monitoring, and operator-driven adjustments in manufacturing systems.

FAQ

  • Q: Is the 2711-K10C10 still in production?  A: No, it is discontinued and considered obsolete.

  • Q: What type of input does this terminal support?  A: It uses a keypad with 16 programmable function keys.

  • Q: What communication options are available?  A: DeviceNet and RS-232 printer ports are supported.

Comparison with Similar Models  Compared to touchscreen variants in the PanelView 1000 series, the 2711-K10C10 relies solely on keypad input, making it less flexible but more durable in environments where touchscreens may be prone to wear or contamination.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Evolving SCADA System Architectures in Industrial Automation

Evolving SCADA System Architectures in Industrial Automation

A robust Supervisory Control and Data Acquisition (SCADA) system serves as the heartbeat of modern industrial operations. Understanding SCADA system architecture is vital for engineers designing efficient control systems. These architectures have evolved from isolated, monolithic structures to highly interconnected, networked ecosystems. Choosing the right design requires balancing data visibility, processing power, and long-term scalability requirements.

Read more
Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Selecting the optimal control architecture is a foundational decision in industrial automation. Engineers must frequently choose between a Programmable Logic Controller (PLC) and a dedicated Motion Controller. While both systems manage machinery, their underlying design philosophies differ significantly, impacting performance, scalability, and system integration.

Read more
Mastering PLC Power Supply Architectures and Operating Voltages

Mastering PLC Power Supply Architectures and Operating Voltages

Selecting the correct operating voltage is a critical step in designing reliable industrial automation systems. Whether you are working with a compact PLC or a large-scale DCS, your power architecture dictates the system's longevity. In this guide, we explore the standard voltage ranges and power distribution strategies required to maintain stable factory automation operations.

Read more