Skip to content

What are you looking for?


You may also like

Yokogawa S9342FA ESB Bus Connector Unit | Safety Network InterfaceYokogawa S9342FA ESB Bus Connector Unit | Safety Network InterfaceYokogawa S9342FA ESB Bus Connector Unit | Safety Network Interface
Yokogawa S9342FA ESB Bus Connector Unit | Safety Network Interface
Yokogawa S9342FA ESB Bus Connector Unit | Safety Network Interface
Yokogawa S9342FA ESB Bus Connector Unit | Safety Network Interface

Yokogawa S9342FA ESB Bus Connector Unit | Safety Network Interface


Only 10 left - Selling fast

PRODUCT SKU : S9342FA

PRODUCT TYPE : Bus Connector Unit

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The S9342FA serves as a critical hardware interface for Yokogawa ProSafe-RS safety instrumented systems, enabling reliable data bridging across the ESB (Extended Safety Backplane) bus. This unit is specifically engineered to maintain high-integrity communication between safety control stations and remote I/O nodes, ensuring deterministic data transfer in mission-critical environments.

Technical Specifications

  • Operating Voltage: 24 VDC nominal

  • Power Consumption: 1.5 W maximum

  • Communication Protocol: Safety Network Communication Protocol (SNcP)

  • Physical Interface: Standard RS-485

  • Module Capacity: Support for up to 32 safety-related I/O modules

  • Diagnostics: Integrated hardware watchdog timer for continuous SNB10D status monitoring

  • Safety Compliance: Certified to IEC 61158 and IEC 61784 standards

  • Thermal Range: -20 to 70 °C (-4 to 158 °F)

  • Form Factor: 75 x 35 x 23 mm

  • Mass: 1 kg 

Industrial Applications

The S9342FA is deployed within distributed safety architectures where SIL3-rated protection is mandatory. It is frequently utilized in Emergency Shutdown Systems (ESD), Fire and Gas (F&G) detection networks, and burner management systems (BMS) across the petrochemical and power generation sectors.

Common Integration FAQ

How does the unit handle communication faults?The S9342FA utilizes its internal watchdog timer to detect processing delays or hardware hangs in the safety node. If a failure is detected, the system transitions to a predetermined failsafe state to maintain plant integrity.

Is this unit hot-swappable within the ESB bus?In most ProSafe-RS configurations, bus connectors should be handled according to specific Yokogawa maintenance protocols to avoid interrupting the safety loop. Always refer to your specific system topology documentation before removal.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Standard electromechanical relays provide basic electrical isolation between low-voltage control circuits and high-power output loads. A traditional switching relay features a magnetic coil driving mechanical Common (COM), Normally-Open (NO), and Normally-Closed (NC) contacts. However, standard relays pose severe functional risks when deployed in critical safety interlock circuits. High current inrush or mechanical wear can weld contacts together permanently. If contact welding occurs in an emergency stop circuit, pressing the button fails to halt hazardous machinery movements. Consequently, global functional safety standards prohibit standard relays for critical machine guarding functions.

Read more
Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Proper wire labeling forms the cornerstone of reliable control system installation and long-term maintenance. In complex industrial automation environments, technicians terminate thousands of conductor ends inside control panels, marshalling racks, and field junction boxes. Ferrules serve as individual tube-shaped sleeve markers slipped onto conductors before final termination. While technicians historically relied on pre-printed individual letter rings, modern control panel builders utilize automated ferrule printing machines. These thermal-transfer printers generate durable, single-sleeve heat-shrink tags directly matching approved wiring schematics, significantly accelerating cabinet assembly workflows.

Read more
Understanding Marshalling Cabinets in Industrial Automation and Control Systems

Understanding Marshalling Cabinets in Industrial Automation and Control Systems

Marshalling cabinets serve as the crucial connection hub between field instruments and centralized processing units. In large DCS and PLC control system architectures, hundreds of multipair field cables run from local junction boxes to the central instrument equipment room. The marshalling cabinet houses field terminal blocks, surge arresters, intrinsic safety isolation barriers, and interposing relays. By segregating field field-wiring terminations from sensitive processor hardware, engineers protect expensive controller backplanes from high-voltage transients. Consequently, this modular separation dramatically streamlines maintenance workflows and simplifies system expansion.

Read more