PRODUCT SKU : ATI3S-S00

PRODUCT TYPE : Terminal Blocks

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Yokogawa ATI3S-S00, also cataloged as the ATI3S Pressure Clamp Terminal Block, operates as a dedicated hardware component for field signal termination and cable interface connection within Yokogawa CENTUM I/O node units.

Suffix Breakdown & Model Matrix

  • ATI3S: Base model designating pressure clamp terminal block assembly for signal termination.
  • -S: Standard signal connection structure suffix.
  • 00: Basic non-option hardware specification variant.

Hardware Specifications

Parameter Specification
Model ATI3S-S00
Brand Yokogawa
Origin Japan
Equipment Function Pressure Clamp Terminal Block Assembly
Termination Format Screwless / Pressure Clamp Terminals
Supported Signal Types Multi-channel Analog / Digital I/O Signals
Weight 0.25 kg
Dimensions Standard Compact I/O Terminal Block Chassis
Operating Temp -20 to 60 deg C
Power Consumption Passive Component (Zero Power Dissipation)

Yokogawa Signal Termination & Loop Protection

The pressure clamp terminal block directly terminates field instrument conductors and routes signals to the corresponding I/O interface module. Integrated terminal insulation maintains channel-to-channel isolation and guards against signal degradation in 4-20 mA HART loop protocol pairs and discrete control lines. The spring-loaded clamp mechanism ensures constant mechanical force on wire leads, preventing intermittent connection loss caused by thermal expansion or enclosure vibration.

Frequently Asked Questions

Q: Does the ATI3S-S00 terminal block require tool-assisted torque checks during routine maintenance?

A: No, the pressure clamp design uses spring-tensioned retention, eliminating the need for periodic screw retightening while maintaining constant electrical contact force.

Q: Can the ATI3S-S00 terminal block be removed without disconnecting individual field conductors?

A: Yes, the terminal assembly unlatches directly from the module baseplate, allowing field wiring to remain fully wired during I/O module replacement.

Field Installation Guidelines

Mount the ATI3S-S00 pressure clamp terminal block onto its corresponding I/O module slot until the locking levers engage fully with the baseplate assembly. Strip field wire insulation to the manufacturer-specified strip length, depress the clamp spring lever with a standard screwdriver, insert the conductor, and release the lever to lock the wire in place. Ensure all cable shields are bonded to the designated cabinet earth grounding bar and maintain physical separation from high-voltage AC lines within the wire duct.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Batch vs Continuous Processing in Industrial Automation: Architectural Strategies for Control Engineers

Batch vs Continuous Processing in Industrial Automation: Architectural Strategies for Control Engineers

Selecting the proper control architecture remains a pivotal decision when designing industrial automation systems. Automation engineers must evaluate whether a batch or continuous process model best fits their production requirements. This fundamental choice influences PLC and DCS programming, hardware redundancy, sensor selection, and overall factory automation layouts.

Read more
Demystifying Signal Isolators: Operating Principles, Architectural Types, and Industrial Applications

Demystifying Signal Isolators: Operating Principles, Architectural Types, and Industrial Applications

Industrial automation systems rely on pristine analog signal transmission across complex control loops. Instrument technicians and system integrators frequently deploy signal isolators to maintain signal integrity between field sensors and control platforms. Eliminating electrical noise, ground loops, and high-voltage transients protects delicate PLC, DCS, and SCADA input channels from permanent damage.

Read more
Demystifying Industrial Control Systems: Comparing PLC, DCS, RTU, SCADA, and PAC

Demystifying Industrial Control Systems: Comparing PLC, DCS, RTU, SCADA, and PAC

Modern factory automation relies on distinct control architectures to manage complex process environments efficiently. Control engineers often evaluate PLC, DCS, RTU, SCADA, and PAC platforms when designing industrial infrastructure. Understanding the functional boundaries of each technology ensures optimal system performance, high availability, and long-term cost efficiency.

Read more