The Yokogawa ANB10D-425/CU2N is a high-availability Duplicated Node Interface Unit (NIU) designed for the CENTUM VP Distributed Control System (DCS). This unit functions as a remote or local I/O subrack, housing up to 8 FIO (Field Input/Output) modules. The "D" designation indicates a Duplexed (Redundant) architecture, providing dual paths for power and communication. This specific model features G3-level corrosive resistance, making it the definitive choice for facilities exposed to aggressive atmospheric contaminants.

Condition: 100% Brand New and Original Factory Sealed.

Part Number Breakdown: ANB10D-425/CU2N

Yokogawa utilizes a comprehensive suffix and option code system to define the NIU's electrical and environmental properties:

  • ANB10D: Duplicated Node Interface Unit (for FIO).

  • -4: Dual-redundant 100-120 V AC Power Supply.

  • 2: 19-inch Rack-mount type with insulation bushing.

  • 5: With G3 Corrosive Resistance

  • /CU2N: Communication interface option specifying connector types and enhanced noise filtering.

Technical Specifications

The ANB10D-425 provides a stable and environmentally hardened electrical environment for critical I/O modules.

  • Number of I/O Slots: 8 slots (supports Analog, Digital, and Communication FIO modules)

  • Interface Bus: ESB Bus (Extended Serial Backplane)

  • Power Supply: 100-120 V AC, 50/60 Hz (Dual-redundant)

  • Mounting: Standard 19-inch rack-mount (with insulation bushing)

  • Environmental Protection: ISA Standard S71.04 Class G3

  • Current Consumption: Max 100 VA (at 100-120 V AC)

  • Redundancy: Supports dual PW481 power units and dual EC401 bus modules.

Engineering Advantages

  • G3-Rated Corrosive Resistance: The internal circuit boards of the ANB10D-425/CU2N are treated with a specialized conformal coating. This prevents silver and copper corrosion caused by aggressive gases in refineries and chemical plants, significantly extending the unit's lifespan in unconditioned environments.

  • Mission-Critical Availability: Engineered to eliminate single points of failure, this unit utilizes dual-redundant power supplies and ESB bus interfaces. This ensures that all 8 I/O modules remain online and communicating with the Field Control Unit (FCU) even if one power circuit or cable fails.

  • Ground Loop Protection: The "2" in the suffix indicates the inclusion of insulation bushings. This physical isolation prevents electrical noise from the cabinet frame from interfering with sensitive analog and digital signals, maintaining high signal-to-noise ratios.

  • Scalable I/O Distribution: This NIU allows for the physical distribution of I/O modules across the plant. By connecting several ANB10D units via YCB301 ESB bus cables, a single controller can manage widely dispersed field points while maintaining high-speed data synchronization.

  • Hot-Swappable Maintenance: All redundant components are hot-swappable. Maintenance teams can replace a faulty power supply or bus interface module while the system is live and the process is running, maximizing plant uptime.

FAQs

  • What is the difference between ANB10D and ANB11D?

    The ANB10D is for standard ESB Bus (local or near-distance), while the ANB11D is used for the Optical ESB Bus, allowing for much longer distances between the controller and the I/O node.

  • How do I connect the ANB10D-425 to the Field Control Unit?

    The NIU connects to the FCU (e.g., AFV30D) using ESB Bus Cables. For a redundant system, these cables must be used in pairs to maintain the duplicated communication path.

  • Does this unit include the I/O modules?

    No. The ANB10D-425/CU2N is the base chassis and power assembly. You must order specific I/O modules (e.g., AAI141, ADV151) separately based on your project's signal requirements.

  • Can I use this unit in a 220V AC environment?

    No. The suffix "-4" indicates a 100-120V AC rating. For 220-240V AC power environments, the ANB10D-2xx series is required.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more
Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Standard electromechanical relays provide basic electrical isolation between low-voltage control circuits and high-power output loads. A traditional switching relay features a magnetic coil driving mechanical Common (COM), Normally-Open (NO), and Normally-Closed (NC) contacts. However, standard relays pose severe functional risks when deployed in critical safety interlock circuits. High current inrush or mechanical wear can weld contacts together permanently. If contact welding occurs in an emergency stop circuit, pressing the button fails to halt hazardous machinery movements. Consequently, global functional safety standards prohibit standard relays for critical machine guarding functions.

Read more