Skip to content

What are you looking for?


You may also like

Schneider TSXSCYCM6030 Modbus Cable for Isolated RS422/485 Tap LinkSchneider TSXSCYCM6030 Modbus Cable for Isolated RS422/485 Tap LinkSchneider TSXSCYCM6030 Modbus Cable for Isolated RS422/485 Tap Link
Schneider TSXSCYCM6030 Modbus Cable for Isolated RS422/485 Tap Link
Schneider TSXSCYCM6030 Modbus Cable for Isolated RS422/485 Tap Link
Schneider TSXSCYCM6030 Modbus Cable for Isolated RS422/485 Tap Link

Schneider TSXSCYCM6030 Modbus Cable for Isolated RS422/485 Tap Link


Only 10 left - Selling fast

PRODUCT SKU : TSXSCYCM6030

PRODUCT TYPE : Modbus Connecting Cable

PRODUCT VENDOR : Schneider


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The TSXSCYCM6030 is a specialized connecting cable from Schneider Electric, engineered for isolated RS422/485 tap link connections. Designed for the Modicon Premium platform, this cable ensures secure and interference-free communication between PLC modules and junction boxes. Its robust construction and precision connectors provide reliable operation in industrial automation environments.

Specifications

• Cable Length: 3 m
• Electrical Connection: SUB-D 25 connector on PLC module side (channel 0), flying leads at junction box side
• Communication Protocol: Modbus character mode
• Net Weight: 0.18 kg

Features and Compatibility

• Accessory Type: Modbus connecting cable for isolated RS422/485 tap link
• Intended Destination: T-junction box connection
• Compatible Modules: TSXSCY21601, TSXSCY11601, TSXSCA50
• Industrial Reliability: Ensures stable data transfer in noisy electrical environments
• Ease of Installation: Pre-terminated connectors reduce wiring time and errors

Applications

The TSXSCYCM6030 is ideal for connecting multiple Modicon Premium PLC modules through RS422/485 isolated networks. It simplifies field wiring, reduces signal interference, and maintains data integrity in complex distributed control systems.

FAQ

Q: Can the TSXSCYCM6030 be used with other Modicon series?
A: It is designed for the Modicon Premium platform but may be compatible with modules supporting isolated RS422/485 taps.

Q: What is the cable length of the TSXSCYCM6030?
A: The standard length is 3 meters. Custom lengths may require special orders.

Q: How is the cable connected to PLCs?
A: The cable uses a SUB-D 25 connector on the PLC side and flying leads on the junction box side for easy integration.

 

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more
Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Standard electromechanical relays provide basic electrical isolation between low-voltage control circuits and high-power output loads. A traditional switching relay features a magnetic coil driving mechanical Common (COM), Normally-Open (NO), and Normally-Closed (NC) contacts. However, standard relays pose severe functional risks when deployed in critical safety interlock circuits. High current inrush or mechanical wear can weld contacts together permanently. If contact welding occurs in an emergency stop circuit, pressing the button fails to halt hazardous machinery movements. Consequently, global functional safety standards prohibit standard relays for critical machine guarding functions.

Read more
Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Proper wire labeling forms the cornerstone of reliable control system installation and long-term maintenance. In complex industrial automation environments, technicians terminate thousands of conductor ends inside control panels, marshalling racks, and field junction boxes. Ferrules serve as individual tube-shaped sleeve markers slipped onto conductors before final termination. While technicians historically relied on pre-printed individual letter rings, modern control panel builders utilize automated ferrule printing machines. These thermal-transfer printers generate durable, single-sleeve heat-shrink tags directly matching approved wiring schematics, significantly accelerating cabinet assembly workflows.

Read more