Only 10 left - Selling fast

PRODUCT SKU : PLX31-EIP-PND

PRODUCT TYPE : Ethernet/IP to Modbus Serial Gateway

PRODUCT VENDOR : PROSOFT


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The PLX31-EFP-MBS by ProSoft provides robust bidirectional communication between Rockwell Automation ControlLogix® and CompactLogix® controllers and Modbus serial devices. It enables reliable data exchange across complex industrial networks while supporting both EtherNet/IP and Modbus serial protocols.

Key Features

  • Dual-protocol gateway: EtherNet/IP to Modbus Serial

  • Client/server support: Multiple connections for ControlLogix and CompactLogix systems

  • Serial interfaces: RS232, RS422, RS485

  • High-speed communication: Low-latency industrial data exchange

  • Floating-point support: Enron and Daniel formats with configurable parity, data, and stop bits

Technical Specifications

EtherNet/IP Interface

  • Class 3 Server Connections: 5

  • Class 3 Client Connections: 2 connected, 1 unconnected

  • Class 1 I/O Connections: 2

  • Maximum I/O Size: 248 bytes input/output

  • Maximum RPI Time: 5 ms per connection

  • CIP Services: Data Table Read (0x4C), Data Table Write (0x4D)

Modbus Serial Interface

  • Supported Function Codes: 1, 2, 3, 4, 5, 6, 15, 16, 22, 23

  • Baud Rate Range: 110 to 115.2 kbps

  • Data Bits: 7 or 8

  • Stop Bits: 1 or 2

  • Parity: None, Even, Odd

  • Communication Modes: RTU (CRC-16), ASCII (LRC)

  • Floating-Point Formats: Enron, Daniel

  • Slave Address Range: 1–247

  • Serial Ports: RS232, RS422, RS485

General

  • Model: PLX31-EFP-MBS

  • Brand: ProSoft

  • Product Type: Ethernet/IP to Modbus Serial Gateway

Applications

Suitable for: Integrating Rockwell Automation PLCs with Modbus serial devices in factory automation, process control, and networked industrial systems requiring reliable bidirectional communication.

FAQ

Q: How many EtherNet/IP client connections does the gateway support?
A: Up to 2 connected and 1 unconnected Class 3 client connections.

Q: Which Modbus serial interfaces are supported?
A: RS232, RS422, and RS485.

Q: Can the gateway handle floating-point data?
A: Yes, it supports Enron and Daniel floating-point formats.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Modern Industrial Automation: Transforming Safety and Efficiency in Mining Operations

Modern Industrial Automation: Transforming Safety and Efficiency in Mining Operations

Industrial automation has evolved from a simple manufacturing tool into the operational backbone of high-risk sectors. Modern mining operations increasingly rely on advanced control systems, programmable logic controllers (PLCs), distributed control systems (DCS), and artificial intelligence to address deep-underground hazards. By replacing manual labor in high-risk zones, factory automation technologies protect personnel while significantly boosting operational throughput.

Read more
Step-by-Step System Cabinet Health Check Guide for PLC and DCS Infrastructure

Step-by-Step System Cabinet Health Check Guide for PLC and DCS Infrastructure

System cabinet health checks ensure long-term reliability in industrial automation. Preventative maintenance prevents hardware degradation, communication loss, and unplanned outages in control networks. This guide outlines the standard operating workflow for inspecting PLC and DCS cabinets to maintain peak performance.
Read more
Top 5 Operational Advantages of HMIs in Modern Factory Automation

Top 5 Operational Advantages of HMIs in Modern Factory Automation

HMIs bridge the gap between operators and complex industrial control networks. Modern factory automation relies on HMIs to deliver real-time visualization, precise control, and data analytics alongside PLC and DCS infrastructure. This technical guide explores five core operational benefits of deploying HMIs in manufacturing.
Read more