Skip to content

What are you looking for?


You may also like

KJ3002X1-BG1 | Emerson DeltaV | 8-Channel Thermocouple Input ModuleKJ3002X1-BG1 | Emerson DeltaV | 8-Channel Thermocouple Input ModuleKJ3002X1-BG1 | Emerson DeltaV | 8-Channel Thermocouple Input Module
KJ3002X1-BG1 | Emerson DeltaV | 8-Channel Thermocouple Input Module
KJ3002X1-BG1 | Emerson DeltaV | 8-Channel Thermocouple Input Module
KJ3002X1-BG1 | Emerson DeltaV | 8-Channel Thermocouple Input Module

KJ3002X1-BG1 | Emerson DeltaV | 8-Channel Thermocouple Input Module


Only 10 left - Selling fast

PRODUCT SKU : KJ3002X1-BG1

PRODUCT TYPE : Thermocouple Input Module

PRODUCT VENDOR : EMERSON


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The Emerson DeltaV Thermocouple Input Module, model KJ3002X1-BG1, is an analog input unit designed to interface with a wide range of field devices. Supporting thermocouples, voltage transmitters, and current transmitters, this module converts analog signals into digital data for precise processing within DeltaV distributed control systems. Built for rugged environments, it ensures reliable performance under extreme operating conditions.

Technical Specifications

  • Manufacturer: Emerson

  • Series: DeltaV Control System

  • Model / Part Number: KJ3002X1-BG1

  • Category: PLCs / Machine Control

  • Subcategory: Thermocouple Input Module

  • Channels: 8 analog input channels

  • Input Compatibility: Thermocouples, voltage transmitters, current transmitters

  • Signal Conversion: Analog-to-digital conversion for DeltaV system integration

  • Power Requirements:

    • Local Bus Power: 12 VDC at 150 mA

    • Bussed Field Power: 30 VDC at 3 A

    • Field Circuit: 30 VDC at 1 A per channel, 3 A per card

  • Environmental Ratings:

    • Operating Temperature: -40°C to +70°C

    • Shock & Vibration: Meets ISA-S71.04-1985 standards

    • Airborne Contaminants Class: G3

    • Humidity: 5%–95% non-condensing

    • Protection Class: IP20

  • Design Features: Compact rack-mounted module, engineered for durability and precision

Application Scenarios

  • Interfaces with thermocouples for accurate temperature measurement.

  • Suitable for process industries such as power generation, petrochemical, and water treatment.

  • Provides reliable analog-to-digital conversion for monitoring and control of critical parameters.

FAQ

Q: What types of inputs are supported?  A: The KJ3002X1-BG1 supports thermocouples, voltage transmitters, and current transmitters.

Q: How many channels are available?  A: It provides eight independent analog input channels.

Q: What environmental conditions can it withstand?  A: The module operates reliably between -40°C and +70°C, with humidity up to 95% non-condensing.

Q: How does this compare to other DeltaV input modules?  A: Unlike standard analog input modules, the KJ3002X1-BG1 is optimized for thermocouple integration, making it ideal for temperature-critical applications.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
The Shift to Flexible IO Modules in Modern Industrial Automation

The Shift to Flexible IO Modules in Modern Industrial Automation

Traditional control systems rely on dedicated Input Output (IO) cards for industrial automation. Each conventional module processes a single signal type, such as Digital Input (DI), Digital Output (DO), Analog Input (AI), or Analog Output (AO). A standard 16-channel card accepts only one specific channel type across all ports. This inflexible hardware design often creates severe engineering bottlenecks during project execution. Engineers frequently must install entirely new cards to accommodate a single extra sensor. Consequently, late design changes increase control cabinet space requirements and drive up project costs.

Read more
DCS Commissioning Steps in Industrial Automation Projects

DCS Commissioning Steps in Industrial Automation Projects

Commissioning a Distributed Control System (DCS) represents a crucial milestone when deploying modern process automation infrastructure. Field engineers must execute systematic verification steps to transition complex control hardware from static installation to dynamic plant control. Proper commissioning ensures that controllers, I/O modules, network switches, and HMI software operate in strict compliance with engineering design specifications before introducing live process fluids.

Read more
PLC and DCS Control System Spares Strategy: Engineering Guidelines

PLC and DCS Control System Spares Strategy: Engineering Guidelines

Modern factory automation relies on high-speed fiber optic backbones to link distributed control systems across noise-intensive industrial environments. Unlike copper wiring, optical fibers transmit data via light pulses, making them completely immune to electromagnetic interference (EMI). Field engineers must master optical cable joining and fusion splicing techniques to guarantee low-loss data transmission across critical Programmable Logic Controller (PLC) and Distributed Control System (DCS) nodes.

Read more