Skip to content

What are you looking for?


You may also like

Honeywell DC-TUIO31 Universal Input Output IOTAHoneywell DC-TUIO31 Universal Input Output IOTAHoneywell DC-TUIO31 Universal Input Output IOTA
Honeywell DC-TUIO31 Universal Input Output IOTA
Honeywell DC-TUIO31 Universal Input Output IOTA
Honeywell DC-TUIO31 Universal Input Output IOTA

Honeywell DC-TUIO31 Universal Input Output IOTA


Only 10 left - Selling fast

PRODUCT SKU : DC-TUIO31 51307772-176

PRODUCT TYPE : Input/Output Termination Assemblies

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for flexible field signal interfacing in Universal I/O controller platforms, the Honeywell DC-TUIO31 (51307772-176) Input/Output Termination Assembly (IOTA) provides direct physical/electrical execution of universal signal routing. The module serves as the termination point for configurable analog and digital field signals, enabling the controller backplane to interface with diverse process instrumentation through a unified hardware architecture.

Hardware Specifications

Parameter Specification
Model DC-TUIO31-51307772-176
Brand Honeywell
Origin USA
Weight 0.2 kg
Dimensions 3.2 cm x 12.7 cm x 12.7 cm
Operating Temp Consult system technical manual
Power Consumption Dependent on host I/O load
Function Universal I/O signal termination

Channel-to-Channel Isolation

The DC-TUIO31 assembly supports channel-to-channel isolation requirements to maintain signal integrity within the universal I/O subsystem. This design prevents electrical interaction between adjacent input or output loops, effectively mitigating the risk of cross-talk and ground loop interference. Maintaining this isolation barrier is mandatory for accurate process data acquisition and control, ensuring that electrical transients or fault conditions occurring on a single field loop are isolated from the controller backplane and do not influence the processing of other connected signals.

Frequently Asked Questions

Q: Does the DC-TUIO31 support software-configurable signal types?

A: The IOTA acts as the physical termination assembly. The software configuration of signal types (analog input/output or digital) is performed at the host I/O module level, provided the channel is supported by the universal I/O architecture.

Q: Is this assembly compatible with existing Series C I/O modules?

A: The DC-TUIO31 is engineered for compatibility with Honeywell universal I/O hardware platforms. Verify the specific I/O module part number and system revision to ensure mechanical and electrical pinout alignment.

Field Installation Guidelines

  • Physical Mounting: Install the IOTA onto the standard chassis mounting rail. Ensure the module is fully seated to achieve a positive connection with the backplane connectors.
  • Wiring and Termination: Utilize shielded twisted-pair cabling for all universal signals. Terminate cable shields at the designated ground lug on the IOTA to maintain electromagnetic compatibility.
  • Segregation: Maintain physical separation between universal I/O signal wires and any high-voltage power or digital switching lines. A minimum distance of 150 mm is required to prevent induced noise on low-level analog signals.
  • Torque Compliance: Tighten all terminal connections using a calibrated screwdriver to the torque specified in the system installation manual. Ensure terminals are clean and free of oxidation before landing field wires.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Modern Industrial Automation: Transforming Safety and Efficiency in Mining Operations

Modern Industrial Automation: Transforming Safety and Efficiency in Mining Operations

Industrial automation has evolved from a simple manufacturing tool into the operational backbone of high-risk sectors. Modern mining operations increasingly rely on advanced control systems, programmable logic controllers (PLCs), distributed control systems (DCS), and artificial intelligence to address deep-underground hazards. By replacing manual labor in high-risk zones, factory automation technologies protect personnel while significantly boosting operational throughput.

Read more
Step-by-Step System Cabinet Health Check Guide for PLC and DCS Infrastructure

Step-by-Step System Cabinet Health Check Guide for PLC and DCS Infrastructure

System cabinet health checks ensure long-term reliability in industrial automation. Preventative maintenance prevents hardware degradation, communication loss, and unplanned outages in control networks. This guide outlines the standard operating workflow for inspecting PLC and DCS cabinets to maintain peak performance.
Read more
Top 5 Operational Advantages of HMIs in Modern Factory Automation

Top 5 Operational Advantages of HMIs in Modern Factory Automation

HMIs bridge the gap between operators and complex industrial control networks. Modern factory automation relies on HMIs to deliver real-time visualization, precise control, and data analytics alongside PLC and DCS infrastructure. This technical guide explores five core operational benefits of deploying HMIs in manufacturing.
Read more