Skip to content

What are you looking for?


You may also like

GE PACSystems RX3i IC694MDL916 16-Point Relay Output ModuleGE PACSystems RX3i IC694MDL916 16-Point Relay Output ModuleGE PACSystems RX3i IC694MDL916 16-Point Relay Output Module
GE PACSystems RX3i IC694MDL916 16-Point Relay Output Module
GE PACSystems RX3i IC694MDL916 16-Point Relay Output Module
GE PACSystems RX3i IC694MDL916 16-Point Relay Output Module

GE PACSystems RX3i IC694MDL916 16-Point Relay Output Module


Only 10 left - Selling fast

PRODUCT SKU : IC694MDL916

PRODUCT TYPE : Relay Output Module

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The IC694MDL916 relay output module from GE Fanuc PACSystems RX3i series provides sixteen individually isolated Form A (Normally Open) relay outputs. Designed for flexible AC/DC switching, it supports a wide voltage range and robust isolation, making it suitable for industrial automation systems requiring reliable relay-based control.

Technical Specifications

  • Manufacturer: GE Fanuc Emerson

  • Product Line: PACSystems RX3i

  • Part Number: IC694MDL916

  • Product Type: Relay Output Module

  • Number of Channels: 16 isolated relay outputs

  • Contact Form: Form A (Normally Open)

  • Operating Voltage Range: 0–125 VDC / 5–250 VAC

  • Nominal Output Voltage: 5/24/125 VDC; 120–240 VAC

  • Output Current per Channel:

    • Minimum: 10 mA

    • Maximum: 4 A (5–250 VAC resistive/general purpose)

    • Maximum: 4 A (5–30 VDC resistive)

    • Maximum: 200 mA (125 VDC resistive)

    • Pilot duty: 2 A per output (5–30 VDC, 5–250 VAC)

    • Lamp load: 2 A per output (5–30 VDC, 5–250 VAC)

  • Switching Current: 4 A maximum

  • Switching Frequency: 20 cycles per minute maximum

  • Response Time: ≤ 10 ms

  • Relay Contact Life: 200,000–1,000,000 operations depending on load type

  • Isolation (Field to Backplane & Frame Ground): 250 VAC continuous; 1500 VAC withstand for 1 minute

  • Isolation (Point-to-Point): Yes

  • Isolation (Group-to-Group): 250 VAC continuous; 1500 VAC withstand for 1 minute

  • Backplane Current Draw: 300 mA at 5 VDC (all outputs ON); 150 mA at 24 VDC relay power (all outputs ON)

  • Terminal Block Options: IC694TBB032 (box-style), IC694TBB132 (extended box-style), IC694TBS032 (spring-style), IC694TBS132 (extended spring-style)

  • Installation: RX3i PACSystems PLC I/O slots

  • Configuration Software: Proficy Machine Edition v5.5 SP2 or later

  • Weight: 0.69 lbs (0.31 kg)

  • Lifecycle Status: Active

Application Scenarios

  • Industrial automation systems requiring AC/DC relay switching

  • Applications needing isolated outputs for safety and reliability

  • Environments where pilot duty and lamp load switching are common

FAQ

Q: How many relay outputs does this module provide?  A: 16 individually isolated Form A (Normally Open) relay outputs.

Q: What voltage ranges are supported?  A: 0–125 VDC and 5–250 VAC.

Q: What is the maximum switching current?  A: 4 Amps for resistive loads at 5–250 VAC or 5–30 VDC.

Q: What is the expected relay contact life?  A: Between 200,000 and 1,000,000 operations depending on voltage and load type.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Importance of Safety Barriers in PLC and DCS Control Systems

Importance of Safety Barriers in PLC and DCS Control Systems

Process industries handle flammable gases and liquids, making electrical instrumentation a constant ignition risk. Engineers designing PLC and DCS networks must implement strict energy-limiting strategies. Intrinsic Safety barriers provide the critical interface that safeguards automation assets and prevents explosions.
Read more
Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

UPS architecture dictates power reliability in process automation. Unplanned voltage sags cause immediate downtime, making robust power backup essential for PLC and DCS networks. This technical guide evaluates the operational principles, key architectures, and tradeoffs between Static and Dynamic Rotary UPS systems.
Read more
Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Signal integrity determines reliability in modern industrial automation. Unwanted electrical noise degrades sensor data, distorts 4-20 mA current loops, and drops fieldbus communications. Engineers working with PLC, DCS, and TSI systems must effectively mitigate these disturbances. This technical guide analyzes key internal and external noise sources affecting control systems.
Read more